ADS ® XiLog+ System User Manual August 2 011 QR 775026 A0 ADS LLC 1300 Meridian Street, Suite 3000 Huntsville, AL 35801 Telephone (256) 430- 3366 / Fax (256) 430- 6633 www.adsenv.com
ADS XiLog+ System User Manual ii Copyright © 2011 ADS® LLC . All rights reserved. ADS ® is a registered trademark of ADS LLC. PrimeWorks ® is a registered trademark of Primayer Limited. Microsoft ® and Win dows® are registered trademarks of Microsoft Corporation. All other brand and product names are tradema rks or registered trademarks of their respective holders. Notice of Proprietary Information The information contained herein represents the latest information available at the time of publication. ADS reserves the right to make any changes or modification s to the content of this document, without notice, to reflect the latest changes to the equipment. No part of this document may be reproduced in any form without the written consent of ADS.
ADS XiLog+ System User Manual iii Table of Contents Chapter 1 System Overview .............................................................. 1 Features ........................................................................................................4 Applications .................................................................................................5 PrimeWorks Software ..................................................................................6 Software Requirements ..........................................................................6 User Access Requirements .....................................................................6 SIM Card ......................................................................................................7 Installing or Removing the SIM Card from the XiLog+ ........................7 Technical Support ......................................................................................10 ADS No -Hassle Warranty and Return Policy ............................................11 New Product Warranty .........................................................................11 Replacement or Loaner Equipment ......................................................11 Shi pping ...............................................................................................11 Product Returns ....................................................................................12 C hapter 2 Deploying the XiLog+ ..................................................... 13 Programming the XiLog+ ..........................................................................14 Configuring the GPRS Network Settings ............................................14 Performing a Signal Strength Test .............................................................16 Installing the XiLog+ .................................................................................18 Input Connections ................................................................................18 C hapter 3 Programming the Logger Using PrimeWorks .............. 21 Launching the PrimeWorks Software ........................................................22 Connected Loggers .....................................................................................23 Communications ........................................................................................24 Program All ..........................................................................................24 Program Changes Only ........................................................................24 Readback ..............................................................................................24 Save Configuration ..............................................................................25 Logger Information ....................................................................................26 Name ....................................................................................................26 Site ID ..................................................................................................26 Phone Number .....................................................................................26 Serial Number ......................................................................................26 Logger Model .......................................................................................26
ADS XiLog+ System User Manual iv Logger Period .......................................................................................27 Additional Notes ..................................................................................27 Installation ..................................................................................................28 Commissioning Mode ..........................................................................28 Read Current Values ............................................................................29 Digital/Analog ......................................................................................29 AutoZero Button ..................................................................................29 Battery Voltage ....................................................................................29 External Power Voltage .......................................................................30 GMS Signal Strength ...........................................................................30 Signal Strength Test .............................................................................30 Analog Channel – Internal Pressure ...........................................................32 Enable Channel ....................................................................................32 Sensor Type ..........................................................................................32 Sensor R ating .......................................................................................32 Units .....................................................................................................32 Data Type .............................................................................................33 Custom Offset ......................................................................................33 Logging Interval ...................................................................................33 Send Data Reports ................................................................................33 Secondary L ogging ..............................................................................33 Analog Channel – Generic .........................................................................34 Enable Channel ....................................................................................35 Sensor Type ..........................................................................................35 Sensor Rating .......................................................................................35 Units .....................................................................................................35 Data Type .............................................................................................35 PCAL ...................................................................................................36 Custom Offset ......................................................................................36 Electrical Range ...................................................................................36 Physical Range .....................................................................................36 Logging Interval ...................................................................................36 Send Data Reports ................................................................................37 Secondary Logging Interval .................................................................37 Digital Channel ..........................................................................................38 Enable ..................................................................................................38 Sensor Profile/Sensor Type ..................................................................38 Pulse Direction .....................................................................................39 Logging Interval ...................................................................................39 Units .....................................................................................................39 Continuous Power ................................................................................39 Combine Flows ....................................................................................39 Send Data Reports ................................................................................40 Calibration Factor ................................................................................40
ADS XiLog+ System User Manual v Meter Reading ......................................................................................40 Meter Units ..........................................................................................40 Secondary Logging ..............................................................................40 Alarm Configuration ..................................................................................42 Enabled ................................................................................................42 Profile Mode ........................................................................................42 Common Alarm Configuration Parameters .........................................42 Threshold Alarms .................................................................................44 Profile and Envelope Alarms ...............................................................44 Remote Data Reporting ..............................................................................48 Message Type .......................................................................................48 Use Automatic GSM Clock Correction ...............................................48 Ignore Daylight Savings .......................................................................49 Host and Alarm Numbers ....................................................................49 FTP Server Address .............................................................................49 FTP Username .....................................................................................49 FTP Password ......................................................................................50 Test Login Details ................................................................................50 Combine Flow and Pressure ................................................................50 Data Transmission ...............................................................................50 C hapter 4 Battery Replacement ...................................................... 53 Chapter 5 9 -Channel Connections ................................................. 57 NXG-302 Expansion Box ....................................................................57 NXG- 303 Bare Wire Cable ..................................................................58 Chapter 6 Appendices ..................................................................... 61 Appendix A: XiLog+ FastTrack Software ................................................62 Viewing the Current Configuration .....................................................63 Programming the Logger .....................................................................63 Testing the Sig nal Strength ..................................................................65 Appendix B: Meter Scaling Tables ...........................................................66 Elster/Kent Helix & Domestic Meters .................................................66 Schlumberger/Actaris/Stream Domestic & Helix Meters ....................66 Sensu s (Socam/Meinecke) ...................................................................67 Supplementary Notes for Meter Scaling Tables ..................................67 Appendix C: Battery Life ..........................................................................69 Power Supply Options .........................................................................69 Appendix D : Airfreight Restrictions .........................................................70
ADS XiLog+ System User Manual 1 C H A P T E R 1 System Overview The ADS® XiLog+ is a telemetric data logger that communicates through the GSM (Global System for Mobile) cellular radio network using either SMS (S hort Messaging Service) or GPRS (General Packet Radio Service) . The XiLog+ is available from the factory with either a quad ba nd antenna or a connector to receive an external antenna. The external antenna version does not support an internal antenna , and the internal version does not support an external antenna . The permanently mounted internal antenna cannot be ex changed or replaced . ADS XiLog+ data logger
ADS XiLog+ System User Manual 2 XiLog+ installed in ground The XiLog+ is available in the following configurations: XiLog+ Model 1F 1P 2i 2 3i 9 Total number of channels 1 1 2 2 3 9 Number of bi -directional flow channels 1 1 1 1 2 Number of analog channels (transducer : voltage or current input) 1 7 (4 voltage; 3 current) Number of internal pressure channels 1 1 2 Current Inputs : 0-10mA and 4- 20mA Voltage Inputs : 0-2V, 0 -5V, 0 -10V Analog Channel Accuracy : ± 0.1%
ADS XiLog+ System User Manual 3 Example of XiLog+ installation Note: The battery packs in the XiLog+ are designed to last 5 years. However, data logger configuration and usage will impact the estimated battery life. Therefore, ADS does not guarantee that all battery packs will last for 5 years . Refer to Appendix C: Battery Life on page 69 for more information. Caution: The XiLog+ contains Lithium batteries and radio transmitters. These batteries must be removed before shipping the unit by air. Please refer to Appendix D: Airfreight Restrictions on page 70 for more information.
ADS XiLog+ System User Manual 4 Features Logs average data at 1- second to 24-hour intervals and flow totals, minimum, and maximum values for 24- hour periods Provides c yclic logging for continuous, indefinite data collection . New data begins overwrit ing the oldest record s once the memory is full. Standard memory size of 1GB accommodates data storage for 200 million readings . Reports logged data via SMS or GPRS and current data (upon request) , real -time alarm, and alarm clear alerts via text message to designated mobile phones. D ata collection can occur as often as every 15 minutes. Fully submersible to IP68 Logs data fro m all flow meters, such as Kent, Meinecke (Socam), Schlumberger, and ABB Kent -Taylor Logs bi -directional flow Logs directly from combination meters Supports i nternal or external pressure transducer Exhibits p ressure accuracy of +0.1% (meet ing the WRC code of practice for network analy sis) Accepts m any variations of analog input Performs i ndependent logging and SMS r eporting Supports e vent logging , including change -of -state monitoring and alarm ing (for overflow monitoring) Offers options for a highly -tuned underground antenna or external antenna s Provides a f lexible wakeup regime, allowing regular contact with the XiLog+ Generates alarms based on designated thresholds or profiles and sends the alarms via SMS/GPRS to established contacts Supports backwar ds compatibility for sensors