Page 1

 
  
ADS
®
 XiLog+ System User Manual  
August 2 011                 QR  775026 A0 
 
 
 
ADS  LLC 
1300 Meridian Street, Suite 3000  Huntsville, AL  35801  
Telephone (256) 430- 3366 / Fax (256) 430- 6633 
www.adsenv.com  

Page 2

ADS XiLog+ System  User Manual  
 ii 
Copyright © 2011 ADS® LLC .  All rights reserved. 
ADS
® is a  registered trademark of ADS  LLC. 
PrimeWorks
® is a registered trademark of Primayer Limited.  
Microsoft
® and Win dows® are registered trademarks of Microsoft 
Corporation. 
All other brand and product names are tradema rks or registered trademarks of 
their respective holders.  
Notice of Proprietary  Information 
The information contained herein represents the latest information available at 
the...

Page 3

ADS XiLog+ System User Manual 
 iii 
Table of Contents  
Chapter 1  System Overview  ..............................................................  1 
Features ........................................................................................................4 
Applications  .................................................................................................5 
PrimeWorks Software  ..................................................................................6 
Software Requirements...

Page 4

ADS XiLog+ System User Manual  
    iv 
Logger Period .......................................................................................27 
Additional Notes  ..................................................................................27 
Installation  ..................................................................................................28 
Commissioning Mode  ..........................................................................28 
Read Current Values...

Page 5

ADS XiLog+ System User Manual 
 v 
Meter Reading  ......................................................................................40 
Meter Units  ..........................................................................................40 
Secondary Logging  ..............................................................................40 
Alarm Configuration  ..................................................................................42 
Enabled...

Page 6

ADS XiLog+ System User Manual  
    vi  

Page 7

ADS XiLog+ System  User Manual 
 1 
C H A P T E R  1  
System Overview  
The ADS® XiLog+ is  a telemetric data logger that communicates  through the 
GSM (Global System for Mobile) cellular radio network using  either SMS 
(S hort Messaging Service)  or GPRS (General Packet Radio Service) .  
The XiLog+ is available from the factory with either a quad ba nd antenna or a 
connector to receive  an external antenna.  The external antenna version does 
not support  an internal antenna , and the internal...

Page 8

ADS XiLog+ System User Manual  
    2 
 
XiLog+ installed in ground 
The XiLog+ is available in the following configurations:  
XiLog+ Model 1F 1P  2i 2 3i  9 
Total number of channels  1  1  2  2  3  9 
Number of bi -directional 
flow channels   1
  1  1  1  2 
Number of analog channels 
(transducer : voltage or 
current input)     1  7 (4 voltage; 
3 current)  
Number of internal pressure 
channels  1  1  2  
Current Inputs :  0-10mA and 4- 20mA 
Voltage Inputs :  0-2V, 0 -5V, 0 -10V  
Analog  Channel...

Page 9

ADS XiLog+ System  User Manual 
 3 
 
Example of XiLog+ installation 
Note:   The battery packs in the  XiLog+ are designed to last 5 years. 
However, data logger configuration and usage will impact the 
estimated battery life.   Therefore, ADS  does not guarantee that all 
battery packs  will last for 5 years .  Refer to Appendix C:  Battery Life  
on page 69 for more information. 
Caution:  The XiLog+ contains Lithium batteries and radio 
transmitters.  These batteries must be removed before shipping...

Page 10

ADS XiLog+ System User Manual  
    4 
 Features 
  Logs average data at 1- second to 24-hour intervals  and flow totals, 
minimum, and maximum values for 24- hour periods 
 Provides c yclic logging for continuous, indefinite data collection .  New 
data begins overwrit ing the oldest record s once the memory is full. 
Standard memory size of 1GB accommodates data storage for  200 
million  readings . 
 Reports  logged data via SMS  or GPRS and current data (upon request) , 
real -time alarm, and...