ADS XiLog+ System User Manual 25 From Last Readback Choosing this radio button ensur es PrimeWorks collects only the data recorded by the logger since the last readback was performed . Note: Click ing on the Quick Readback button on the t itle bar or the Readback button corresponding to a logger in the Connected Loggers drop-down list accomplishes the same operation as selecting the From Last Readback option. All Data Choosing thi s radio button ensures PrimeWorks collects all the data available in the logger to the PC. If several months of data are available in the logger , this process may take several minutes. Custom Dates Choosing this radio button ensures PrimeWorks collects data from the logger for the range indicated in the From and To fields. Selectin g this option enables the From /To calendar options . Designate the start and end dates of the data for readback from these fields. The dat es available for selection are limited to the dates for which data is available in t he logger. Channels to Readback (applicable only when collecting data remotely ) Select the checkboxes corresponding to the channels representing the data desired for readback. Th e list contains only the channels that are available for readback. After selecting the readback options and c licking on the Readback button, PrimeWorks initiates the readback process and displays the progress on screen. When performing a readback via USB, PrimeWorks calculates and displays the estimated time of completion . Save Configuration Selecting this option save s the current configuration for the selected logger to the PrimeWorks database. Note: Selecting the program or readback options automatically saves the configuration.
ADS XiLog+ System User Manual 26 Logger Information Logger Information window Name This editab le field contains t he name that will appear in the PrimeWorks database for the selected logger. Change or edit the name as necessary. Site ID This editable field displays a unique ID that can be programmed into the logger. The logger includes this name with the name of the site when transmitting data via FTP. Phone Number This editable field displays the phone number of the logger. Once entered and saved to the logger memory, it is not necessary to enter this number again. Serial Number This field displays the serial numb er of the logger. It is not an editable field . Logger Model This field displays the logger model. It is not an editable field .
ADS XiLog+ System User Manual 27 Logger Period This section indicates the date and time period for which the logger records data. Start Immediately Select ing this radio button initiate s logging immediately once logger programming is c omplete and continues logging indefinitely. Custom Dates Selecting this radio button initiates and sustains logging for the date /time range designated in the Logging Start and End Time fields. Logging Start and End Time These fields represent the date and time period for which the XiLog+ records data. Enter the dates and times in the corresponding fields based on the option selected above. The calendar buttons also may be used t o designate the dates. T he Logging Start Time fields designate the date and time at which to initiate logging only when the Custom Dates option is in use. Once th e date and time designated in the Logging End Time fields occur, the logger will discontinue logging data until a new logging session is initiated. Leaving the field blank ensures logging continues indefinitely. Under this condition, logging follows a cyclical pattern in which newer data begins to overwrite older data once the memory becomes ful l. Additional Notes This editable field contains information beneficial or applicable to the current site or logger. Enter or edit relevant content as necessary.
ADS XiLog+ System User Manual 28 Installation Installation window This window includes all the parameters relevant to installing the logger at the site. Comm issioning Mode This drop- down list contains the options available for communication: Commissioning Mode menu options On Selecting this option places the logg er in commissioning mode . This mode ensures the logger remain s powered up, connect ed to the GSM network, and available for communication. Note: Do not maintain a logger in commissioning mode for a long period of time. This will have a detrimental effect on battery life. Note: Leaving a logger in commissioning mod e will generate and send an SMS alarm at 00:00 every day until this mode is discontinued. Discontinue this mode by sending the string #CMOFF to the logger from a cellular phone. Off Selecting this option power s up the modem only as designated under the cur rent setup. This is the standard operating mode.
ADS XiLog+ System User Manual 29 Freight Mode Selecting this mode prevents the modem from powering up so that the logger cannot transmit, even when the logger has been programmed to transmit (e.g., because of an alarm) . Select this option when air freighting a logger, even if the SIM card has been removed. ADS ships all loggers transported by air in this mode. Read Current Values Selecting this checkbox displays the current values from the attached logger in the Digital , Analog, Battery V oltage/External Power Voltage , and GSM Signal Strength fields, as applicable. PrimeWorks will request data from the logger every second. Pressure and other analog data update at this interval , but flow values require up to 1 minute to update based on the sample rate programmed in to the logger. Digital/Analog These field s display the current value and units for each channel. The number of values displayed varies based on the logger features and programming. If the XiLog+ is not logging data on a channel , the corresponding field will not display a reading . A channel that is not logging data may indicate the channel has not been enabled or the end date and time designated for logging data has passed. AutoZero Button Clicking on this button removes the curr ent offset and forces the analog channel to read zero. This button is available only when the XiLog+ is logging pressure, depth, or height on an analog channel. Note: Use this option only with the transducer open to atmospheric pressure. T his new offse t will apply onl y to future data. It will not be applied to previously recorded data. Battery Voltage This field displays the current internal battery voltage (nominally 7.2V). If it reads low and the battery requires replacement, PrimeWorks will display a warning once the logger is connected to the computer .
ADS XiLog+ System User Manual 30 External Power Voltage This field displays the external power voltage measured by the logger. If the logger is attached via USB, PrimeWorks will display the USB voltage being su pplied to the logger ( typically 5 volts). If the voltage is request ed remotely , PrimeWorks will display the voltage coming from the external power supply. GMS Signal Strength This field indicates the current GSM signal strength measured by the logger currently (prov ided the l ogger is powered up to the GSM network) or the last time it was on-line. Signal Strength Test The signal strength test verifies the logger can communicate with the cellular network at the current location (of potential deployment) . Signal Strength sub-window Interval Between Samples This field indicates the amount of time in seconds between each test sample. Modify this setting manually or using the up/down arrows. Delay before test start This field displays the amount of time in seconds to delay before initiating the test. The delay period begins when PrimeWorks sends the command to the logger to initiate the signal strength test. Modify this setting manually or using the up/down arrows. Sample Count This field indicates the number of test samples to t ake during the test. Modify this setting manually or using the up/down arrows.
ADS XiLog+ System User Manual 31 Start Test Selecting t his button initiates the signal strength test. The logger will begin measur ing the signal strength once the delay period has passed. A counter will count down the time until the test is due to begin to allow sufficient time for placing the logger in the appropriate position. This counter also will be used to identify the end of the test. When the test is complete, recover the logger and read the results. Get latest test results Selecting this button displays the result s from the last signal strength test recorded by the logger and indicates the quality of the results (good, adequate , or inadequate ).
ADS XiLog+ System User Manual 32 Analog Channel – Internal Pressure Channels (Analog Pr essure) window This window includes the parameters for setting up the internal pressure transducer channel. A green dot next to the channel name indicates the channel is enabled and recording data. Enable Channel Selecting this checkbox enables the channe l on the logger. Not all channels on a logger must be enabled when it is in use. Disabled c hannels do not use power. Sensor Type This parameter does not apply to internal pressure sensors . Sensor Rating This value indicates the maximum rating of the internal pressure sensor. It is not an editable value . Units This drop- down list contains the options for the units of measure corresponding to the pressure channel.
ADS XiLog+ System User Manual 33 Data Type This drop-down list contai ns the options for selecting the type of data that will be recorded through the channel. C ustom Offset This field indicates the offset. Modify this value (when necessary) manually or using the up/down arrows. For example, enter the value representing the offset for adding the ground level to all pressure value s. Logging Interval This drop-down list contains the options for selecting the measurement interval at which to log data on this channel . Options from 1 second to 24 hours are available. All data logged on a channel represent s averaged data ( based on the number of samples taken). XiLog+ records the averaged data and daily minimum and maximum values for each channel. Send Data Reports Selecting this checkbox ensures the logger send s data reports by SMS or GPRS based on the frequency designated for remote data reporting. T he minimum logging interval for data sent through SMS is 1 minute. Therefore, d ata sent through SMS based on a shorter interval first must be averaged at a 1-minute interval before being sent. Note: Selecting a logging interval of les s than 15 minutes using SMS requires sending more than one SMS per day for each channel. For example, sending 1-minute SMS data every day requires sending 15 SMS per channel per day. Secondary Logging Some XiLog+ models allow a secondary logging interval for logging the same channel input at a second rate. This data can be reported remotely, or logged internally and remotely requested (as required ).
ADS XiLog+ System User Manual 34 Analog Channel – Generic This window includes the parameters for setting up the generic analog channels pre sent on the XiLog+ 2 and XiLog+ 9 models . Three options are available based on the channel capabilities : current, millivolt, and voltage. If the channel can support all three options, a drop- down menu allows for selection of the one to use. Each option requires a different type of cable to interface to the sensor. Generic Analog – Current (mA) example Generic Analog – Voltage example