     25 
      From Last Readback 
    Choosing this radio button ensur es PrimeWorks collects only the data 
    recorded by the logger since the last readback was performed . 
    Note:  Click ing  on the Quick Readback button on the t itle bar or the 
    Readback  button corresponding  to a logger in the Connected 
    Loggers drop-down list accomplishes the same operation as selecting 
    the From Last Readback  option. 
     All Data  
    Choosing thi s radio button ensures PrimeWorks  collects all the data available 
    in the logger  to the PC.  If several months of data are available in the logger , 
    this process may  take several minutes.  
      Custom Dates 
    Choosing this radio button ensures PrimeWorks  collects data from the logger 
    for the range indicated in the From  and To fields.  Selectin g this option 
    enables the From /To  calendar options .  Designate the start and end dates of 
    the data for readback from these fields.   The dat es available for selection are 
    limited to the dates for which data is available in t he logger. 
      Channels to Readback 
    (applicable only when collecting data remotely )  Select the checkboxes 
    corresponding to the channels representing the data desired for readback.  Th e 
    list contains only  the channels that are available for readback.  
    After selecting the readback options and c licking on the Readback button, 
    PrimeWorks  initiates the readback process and  displays the progress on 
    screen.   When performing a readback  via USB, PrimeWorks calculates and 
    displays the estimated time of completion . 
    Save Configuration 
    Selecting this option save s the current configuration for the selected logger to  
    the PrimeWorks  database. 
    Note:  Selecting  the program or readback options automatically saves 
    the configuration.  
    						
    							ADS XiLog+ System User Manual 
     26 
    Logger Information 
     
    Logger Information  window 
    Name 
    This editab le field contains t he name that will appear in the PrimeWorks  
    database for the selected logger.  Change or edit the name as  necessary. 
    Site ID 
    This editable field displays a unique ID that can be programmed into the 
    logger.  The logger includes this name with the name of the  site when 
    transmitting data via FTP.   
    Phone Number 
    This editable field displays the phone number of the logger.  Once entered and 
    saved to the logger memory, it is not necessary to enter this number again.  
    Serial Number 
    This field displays the serial numb er of the logger.  It is not an editable field . 
    Logger Model 
    This field displays the logger model.  It is not an editable field .  
    						
    							ADS XiLog+ System  User Manual 
     27 
    Logger Period 
    This section indicates the date  and time period for which the logger  records 
    data.    
      Start Immediately   
    Select ing this radio button initiate s logging immediately once  logger 
    programming is c omplete and continues logging indefinitely.  
      Custom Dates  
    Selecting this radio button initiates and sustains logging for the date /time 
    range designated in the Logging Start  and End Time fields. 
      Logging Start and End Time  
    These fields represent the date and time period for which the XiLog+ records 
    data.   Enter the dates and times in the corresponding fields based on the option 
    selected above.  The calendar buttons also may be used t o designate the dates.  
    T he Logging Start Time  fields designate the date and time at which to initiate 
    logging only when the Custom Dates  option is in use. 
    Once th e date and time designated in the Logging End Time  fields occur, the 
    logger will discontinue logging data until a new logging session is initiated.  
    Leaving the field blank ensures  logging continues indefinitely.  Under this 
    condition, logging follows a cyclical pattern in which newer data begins to 
    overwrite older data once the memory becomes ful l.   
    Additional Notes  
    This editable field contains information beneficial or applicable to the current 
    site or logger.  Enter or edit relevant content as necessary.   
    						
    							ADS XiLog+ System User Manual 
     28 
    Installation  
     
    Installation  window  
    This window  includes all the parameters  relevant to installing the logger at the 
    site.  
    Comm issioning  Mode 
    This drop- down list contains the options available  for communication: 
     
    Commissioning Mode  menu options  
     On  
    Selecting this option places the logg er in commissioning mode .  This mode 
    ensures the logger remain s powered up, connect ed to the GSM network, and 
    available for communication. 
    Note:   Do not maintain a  logger in commissioning mode for a long 
    period of time.  This will have a detrimental effect on battery life.  
    Note:  Leaving a logger in commissioning mod e will generate and 
    send an SMS alarm at 00:00 every day until this mode is discontinued. 
    Discontinue this mode by sending the string #CMOFF to the logger 
    from a cellular phone. 
     Off 
    Selecting this option power s up the modem only as designated under the 
    cur rent setup.  This is the standard operating mode.  
    						
    							ADS XiLog+ System  User Manual 
     29 
      Freight Mode  
    Selecting this mode prevents  the modem from powering up so that the logger 
    cannot  transmit, even when the logger has been  programmed to transmit (e.g., 
    because of an alarm) .  Select  this option when air freighting a logger, even if 
    the SIM card has been  removed.  ADS ships all loggers transported by air in 
    this mode. 
    Read  Current Values  
    Selecting this checkbox displays  the current values from the attached logger  in 
    the Digital , Analog, Battery V oltage/External Power Voltage , and GSM 
    Signal Strength fields, as applicable.  PrimeWorks  will request data from 
    the logger every second.  Pressure and other analog data update at  this 
    interval , but flow values require  up to 1 minute to update based on the  sample 
    rate programmed in to the logger.  
    Digital/Analog  
    These field s display  the current value and units for each channel.  The number 
    of values displayed varies  based on the logger features and  programming.  If 
    the XiLog+ is not logging data on a channel , the corresponding field will not 
    display a reading .  A channel that is not logging data may indicate the  channel 
    has not been enabled  or the end date and time designated for logging data has  
    passed.  
    AutoZero Button 
    Clicking on this button removes the curr ent offset and forces the analog 
    channel to read zero.  This button is available only  when the XiLog+ is 
    logging pressure, depth, or height on an analog channel.  
    Note:   Use this option only with the transducer open to atmospheric 
    pressure.  T his new offse t will apply onl y to future data.  It  will not be 
    applied to previously recorded data.  
    Battery Voltage 
    This field displays the current internal battery voltage (nominally 7.2V).  If it 
    reads low and the battery requires replacement,  PrimeWorks will display a 
    warning once the logger is connected to the computer .  
    						
    							ADS XiLog+ System User Manual 
     30 
    External Power Voltage  
    This field displays the external power voltage measured by the logger.   If the 
    logger is attached  via USB,  PrimeWorks  will display the USB voltage being 
    su pplied to the logger ( typically 5 volts).  If  the voltage is request ed remotely , 
    PrimeWorks  will display the voltage coming  from the external power supply. 
    GMS Signal Strength  
    This field indicates the current GSM signal strength measured by the logger  
    currently (prov ided the l ogger is powered up to the GSM network)  or the last 
    time it was  on-line.  
    Signal Strength Test  
    The signal strength test verifies  the logger can communicate with the cellular  
    network at the current location (of potential deployment) . 
     
    Signal Strength sub-window  
     Interval Between Samples 
    This field indicates  the amount of time in seconds between each  test sample.  
    Modify this setting manually or using the up/down arrows. 
      Delay before test start  
    This field displays the amount of time in seconds to delay before initiating  the 
    test.   The delay period begins  when PrimeWorks sends the command to the 
    logger to initiate the signal strength test.   Modify this setting manually or 
    using the up/down arrows. 
      Sample Count  
    This field indicates  the number of test samples to t ake during the test.  Modify 
    this setting manually or using the up/down arrows.  
    						
    							ADS XiLog+ System  User Manual 
     31 
      Start Test  
    Selecting t his button initiates the signal strength test.  The logger will begin 
    measur ing the signal strength  once the delay period has passed.  A counter  will 
    count down the time until the test is due to  begin to allow sufficient time for 
    placing the logger in the appropriate position.  This counter  also will be used 
    to  identify the end of the test. 
    When the test is complete, recover the logger and read the results.  
      Get latest test results 
    Selecting this button displays the result s from the last signal strength test 
    recorded by the logger  and indicates the quality of the results  (good, adequate , 
    or inadequate ).  
    						
    							ADS XiLog+ System User Manual 
     32 
    Analog Channel –  Internal Pressure 
     
    Channels (Analog Pr essure) window  
    This window  includes the parameters for setting up the  internal pressure 
    transducer channel.  A green  dot next to the channel name indicates the 
    channel is enabled and recording data. 
    Enable Channel  
    Selecting this checkbox enables the channe l on the logger.  Not all channels 
    on a logger must  be enabled when it is in use.  Disabled c hannels do not use 
    power. 
    Sensor Type  
    This parameter does not apply to internal pressure sensors . 
    Sensor Rating 
    This value indicates the maximum rating of the internal pressure sensor.  It is 
    not an editable value . 
    Units 
    This drop- down list contains the options for the units of measure 
    corresponding to the pressure channel.   
    						
    							ADS XiLog+ System  User Manual 
     33 
    Data Type  
    This drop-down list contai ns the options for selecting the type of data that will 
    be recorded through the channel. 
    C ustom Offset 
    This field indicates the offset.   Modify this value (when necessary) manually 
    or using the up/down arrows.  For example, enter the value representing the 
    offset for adding the ground level to all pressure value s. 
    Logging Interval  
    This drop-down list contains the options  for selecting the measurement 
    interval at which  to log data on this channel .  Options from 1 second to 24 
    hours are available.   All data logged on a channel represent s averaged data 
    ( based on the  number of samples taken).  XiLog+ records the averaged data 
    and daily minimum and maximum values for each channel.    
    Send Data Reports 
    Selecting this checkbox ensures the logger send s data reports by SMS or 
    GPRS  based on the frequency designated  for remote data reporting.  
    T he minimum logging interval for  data sent through SMS is 1 minute.  
    Therefore, d ata sent through SMS based on a shorter interval first must be 
    averaged  at a 1-minute interval before being sent. 
    Note:   Selecting a logging interval of les s than 15 minutes using SMS 
    requires sending more than one SMS per day for each  channel.  For 
    example, sending 1-minute SMS data every day requires sending  15 
    SMS per channel per day. 
    Secondary Logging 
    Some XiLog+  models allow a secondary logging interval  for logging the same 
    channel input at a second rate.  This data  can be reported remotely, or logged 
    internally and remotely requested  (as required ).  
    						
    							ADS XiLog+ System User Manual 
     34 
    Analog Channel –  Generic 
    This window  includes the parameters for  setting up the generic analog 
    channels pre sent on the XiLog+ 2 and XiLog+ 9 models .  Three options are 
    available based on the channel capabilities : current, millivolt, and voltage.  If 
    the channel can support all three options, a drop- down menu allows for 
    selection of the one  to use. 
     
    Each option requires a different type of cable to interface to the sensor.  
     
    Generic Analog – Current  (mA) example 
     
    Generic Analog –  Voltage  example  
    						