    38
    [Conversion from actual data to bulk data]d[0-6]: actual data
    b[0-7]: bulk data
    b[0] = 0;
    for( I=0; I
    						
    							 Data List
    39
    4.2.3 Module Name
    *1) 0:CH1 - 71:CH72
    72:ST IN 1L - 87:ST IN 8R
    *2) 256:MIX 1 - 279:MIX 24
    *3) 512:MATRIX 1 - 519:  MATRIX 8
    *4) 1024:STEREO L - 1026:STEREO C
    *5)  512: will be used if the recalling or storing data is only one.
    *6) 0:  GEQ1A, 1:  GEQ1B, 2:  GEQ2A, ... 36:  GEQ19A, 37:GEQ19B
    38:  EFFECT GEQ1A, 39:  EFFECT GEQ1B, 
    40:  EFFECT GEQ2A, ... 52:  EFFECT GEQ8A, 53:  EFFECT GEQ8B
    *7) 0:Effect1- 7:Effect8
    *8) 1280:CH1 - 1351:CH72
    1352:ST IN 1L - 1367:ST IN 8R
    *9) 0:  Premium Rack 1A, 1:  Premium Rack 1B, 
    2:  Premium Rack 2A, ... 14:  Premium Rack 8A, 15:  Premium Rack 8B4.3 FUNCTION CALL - LIBRARY EDIT -4.3.1 Format (PARAMETER CHANGE)
    ReceptionData will be received when [PARAMETER CHANGE Rx] is on and the Device 
    number of both [Rx CH] and SUB STATUS match.
    The data will be echoed when [PARAMETER CHANGE ECHO] is on.
    The corresponding memory/library will be changed immediately the data is 
    received.TransmissionPARAMETER CHANGE will be sent in reply to Request.
    If [PARAMETER CHANGE ECHO] is on, the message will be sent as it is.
    4.3.2 Function Name
    4.3.3 Module Name
    Module NameScene “SCENE___”
    Input EQ “INEQ____”
    Output EQ “OUTEQ___”
    Dynamics “DYNA____”
    Input CH “INCHNNL_”
    Output CH “OUTCHNNL”
    GEQ “GEQ_____”
    8BandPEQ “8PEQ____”
    Effect “EFFECT__”
    Portico5033 “P5033___”
    Portico5043 “P5043___”
    U76 “U76_____”
    Opt-2A “OPT-2A__”
    EQP-1A “EQ-1A___”
    Dynamic EQ “DYNAEQ__”
    Buss Comp 369 “BSCMP369”
    Dante Input Patch “DANTEIN_”Function
    Number
    Channel*1)
    tx/rx
    “LibStr__” SCENE 1-300 *5)tx/rx
    INPUT EQ LIB 41-199 *1)
    tx/rx
    OUTPUT EQ LIB 4-199 *2) *3) *4)
    tx/rx
    Dynamics LIB 42-199 *1) *2) *3) *4) *8)
    tx/rx
    INPUT CH LIB 1-199 *1)
    tx/rx
    OUTPUT CH LIB 1-199 *2) *3) *4)
    tx/rx
    GEQ LIB 1-199 *6)
    tx/rx
    8BandPEQ LIB 1-199 *6)
    tx/rx
    EFFECT LIB 28-199 *7)
    tx/rx
    Premium Effect LIB 1-100 *9)
    tx/rx
    Dante Input Patch LIB 1-10 *5)
    tx/rx
    “LibUnStr” SCENE 1-300 0
    tx
    INPUT EQ LIB 41-199 0
    tx
    OUTPUT EQ LIB 4-199 0
    tx
    Dynamics LIB 42-199 0
    tx
    INPUT CH LIB 1-199 0
    tx
    OUTPUT CH LIB 1-199 0
    tx
    GEQ LIB 1-199 0
    tx
    8BandPEQ LIB 1-199 0
    tx
    EFFECT LIB 28-199 0
    tx
    Premium Effect LIB 1-100 0
    tx
    Dante Input Patch LIB 1-10 0
    tx
    “LibRcl__” SCENE 0-300 *5)
    tx/rx
    INPUT EQ LIB 1-199 *1)
    tx/rx
    OUTPUT EQ LIB 1-199 *2) *3) *4)
    tx/rx
    Dynamics LIB 1-199 *1) *2) *3) *4) *8)
    tx/rx
    INPUT CH LIB 0-199 *1)
    tx/rx
    OUTPUT CH LIB 0-199 *2) *3) *4)
    tx/rx
    GEQ LIB 0-199 *6)
    tx/rx
    8BandPEQ LIB 1-199 *6)
    tx/rx
    EFFECT LIB 1-199 *7)
    tx/rx
    Premium Effect LIB 0-100 *9)
    tx/rx
    Dante Input Patch LIB 0-10 *5) 
    tx/rx
    “LibUnRcl” SCENE 0 *5)
    tx
    INPUT EQ LIB 0 *1)
    tx
    OUTPUT EQ LIB 0 *2) *3) *4)
    tx
    Dynamics LIB 0 *1) *2) *3) *4) *8)
    tx
    INPUT CH LIB 0 *1)
    tx
    OUTPUT CH LIB 0 *2) *3) *4)
    tx
    GEQ LIB 0 *6)
    tx
    8BandPEQ LIB 0 *6)
    tx
    EFFECT LIB 0 *7)
    tx
    Premium Effect LIB 0 *9)
    tx
    Dante Input Patch LIB 0 *5) 
    tx
    “LibStrUd” SCENE 0 0
    “LibRclUd” SCENE 0 0STATUS 11110000 F0
    System exclusive message
    ID No. 01000011 43
    Manufacturer's ID number (YAMAHA)
    SUB STATUS 0001nnnn 1n
    n=0-15 (Device number=MIDI Channel)
    GROUP ID 00111110 3E
    Digital mixer
    MODEL ID 00011001 19
    CL Series
    DATA CATEGORY 00000000 00
    OTHER DATA
    FUNCTION NAME 01001100 “L”
    (ASCII CODE)
    01101001 “i”
    (ASCII CODE)
    01100010 “b”
    (ASCII CODE)
    0fffffff ff
    (ASCII CODE)
    0fffffff ff
    (ASCII CODE)
    Function
    Number
    Channel*1)
    tx/rx
    0fffffff ff
    (ASCII CODE)
    0fffffff ff
    (ASCII CODE)
    0fffffff ff
    (ASCII CODE)
    MODULE NAME 0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    DATA 0sssssss sh
    number -source start High
    0sssssss sl
    number -source start Low
    0eeeeeee eh
    number -source end High
    0eeeeeee el
    number -source end Low
    0ddddddd dh
    number -destination start High
    0ddddddd dl
    number -destination to start Low
    EOX 11110111 F7
    End of exclusive
    Function NameCopy “LibCpy__”
    Paste “LibPst__”
    Clear “LibClr__”
    Cut “LibCut__”
    Insert “LibIns__”
    Edit Undo “LibEdtUd”
    Module Name
    Function
    SCENE LIB  “SCENE___” Copy, Paste, Clear, Cut, Insert, EditUndo
    INPUT EQ LIB  “INEQ____” Clear Only
    OUTPUT EQ LIB  “OUTEQ___” Clear Only
    Dynamics LIB  “DYNA____” Clear Only
    INPUT CH LIB “INCHNNL_” Clear Only
    OUTPUT CH LIB “OUTCHNNL” Clear Only
    GEQ LIB “GEQ_____” Clear Only
    8BandPEQ LIB “8PEQ____” Clear Only
    EFFECT LIB “EFFECT__” Clear Only
    Portico5033 LIB “P5033___” Clear Only
    Portico5043 LIB “P5043___” Clear Only
    U76 LIB “U76_____” Clear Only
    Opt-2A LIB “OPT-2A__” Clear Only
    EQP-1A LIB “EQ-1A___” Clear Only
    DynamicEQ LIB “DYNAEQ__” Clear Only
    Buss Comp 369 LIB “BSCMP369” Clear Only
    Dante Input Patch LIB “DANTEIN_” Clear Only 
    						
    							 Data List
    40
    4.4 FUNCTION CALL - LIBRARY ATTRIBUTE -4.4.1 Format (PARAMETER CHANGE)
    ReceptionData will be received when [PARAMETER CHANGE Rx] is on and the Device 
    number of both [Rx CH] and SUB STATUS match.
    The data will be echoed when [PARAMETER CHANGE ECHO] is on.
    When the message is received, the title of the specified memory/library will be 
    edited.TransmissionPARAMETER CHANGE will be sent in reply to Request.
    If [PARAMETER CHANGE ECHO] is on, the message will be sent as it is.
    4.4.2 Format (PARAMETER REQUEST)
    ReceptionThe PARAMETER CHANGE will be sent with Device number [Rx CH] immediately 
    the data is received.4.4.3 Module Name
    4.5 EXIST LIBRARY RANGE4.5.1 Format (PARAMETER CHANGE)
    TransmissionWhen CL series receives Library Exist request command from outside, the answer 
    will be sent back with the following Parameter change.
    This packet shows smallest library number range that exists and not read only. 
    Top number is requested number or more.
    -Example-
    SCENE is stored 5,6,7,10,100 and 101
    Request Number:  0 
    Data : Valid, Top Number : 5, End Number 7
    Request Number:  8
    Data : Valid, Top Number : 10, End Number 10
    Request Number:  11
    Data : Valid, Top Number : 100, End Number 101
    Request Number:  102 
    Data : Invalid, Top Number : 0, End Number 0
    STATUS 11110000 F0
    System exclusive message
    ID No. 01000011 43
    Manufacturer's ID number (YAMAHA)
    SUB STATUS 0001nnnn 1n
    n=0-15 (Device number=MIDI Channel)
    GROUP ID 00111110 3E
    Digital mixer
    MODEL ID 00011001 19
    CL Series
    DATA CATEGORY 00000000 00
    OTHER DATA
    FUNCTION NAME 01001100 “L”
    (ASCII CODE)
    01101001 “i”
    (ASCII CODE)
    01100010 “b”
    (ASCII CODE)
    01000001 “A”
    (ASCII CODE)
    01110100 “t”
    (ASCII CODE)
    01110010 “r”
    (ASCII CODE)
    01100010 “b”
    (ASCII CODE)
    01110100 “t”
    (ASCII CODE)
    MODULE NAME 0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    DATA 0nnnnnnn nh
    Scene/Library number High
    0nnnnnnn nl
    Scene/Library number Low
    0eeeeeee eh
    Element High
    0eeeeeee el
    Element Low
    0iiiiiii ih
    Index High
    0iiiiiii il
    Index Low
    0ccccccc ch
    Channel High
    0ccccccc cl
    Channel Low
    0000dddd dd
    Data28~31bit
    0ddddddd dd
    Data21~27bit
    0ddddddd dd
    Data14~20bit
    0ddddddd dd
    Data7~13bit
    0ddddddd dd
    Data0~6bit
    EOX 11110111 F7
    End of exclusive
    STATUS 11110000 F0
    System exclusive message
    ID No. 01000011 43
    Manufacturer's ID number (YAMAHA)
    SUB STATUS 0011nnnn 3n
    n=0-15 (Device number=MIDI Channel)
    GROUP ID 00111110 3E
    Digital mixer
    MODEL ID 00011001 19
    CL Series
    DATA CATEGORY 00000000 00
    OTHER DATA
    FUNCTION NAME 01001100 “L”
    (ASCII CODE)
    01101001 “i”
    (ASCII CODE)
    01100010 “b”
    (ASCII CODE)
    01000001 “A”
    (ASCII CODE)
    01110100 “t”
    (ASCII CODE)
    01110010 “r”
    (ASCII CODE)
    01100010 “b”
    (ASCII CODE)
    01110100 “t”
    (ASCII CODE)
    MODULE NAME 0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    DATA 0nnnnnnn nh
    Scene/Library number High
    0nnnnnnn nl
    Scene/Library number Low
    0eeeeeee eh
    Element High
    0eeeeeee el
    Element Low
    0iiiiiii ih
    Index High
    0iiiiiii il
    Index Low
    0ccccccc ch
    Channel High
    0ccccccc cl
    Channel Low
    EOX 11110111 F7
    End of exclusive
    Module Name
    Number
    SCENE LIB  “SCENE___” 0-300 (0:response only)
    INPUT EQ LIB  “INEQ____” 1-200 (1-40:response only)
    OUTPUT EQ LIB  “OUTEQ___” 1-200 (1-3:response only)
    Dynamics LIB  “DYNA____” 1-200 (1-41:response only)
    INPUT CH LIB “INCHNNL_” 0-200 (0:response only)
    OUTPUT CH LIB “OUTCHNNL” 0-200 (0:response only)
    GEQ LIB “GEQ_____” 0-200 (0:response only)
    8BandPEQ LIB “8PEQ____” 0-199 (0:response only)
    EFFECT LIB “EFFECT__” 1-200 (1-27:response only)
    Portico5033 LIB “P5033___” 0-100 (0:response only)
    Portico5043 LIB “P5043___” 0-100 (0:response only)
    U76 LIB “U76_____” 0-100 (0:response only)
    Opt-2A LIB “OPT-2A__” 0-100 (0:response only)
    EQP-1A LIB “EQ-1A___” 0-100 (0:response only)
    DynamicEQ LIB “DYNAEQ__” 0-100 (0:response only)
    Buss Comp 369 LIB “BSCMP369” 0-100 (0:response only)
    Dante Input Patch LIB “DANTEIN_” 0-10 (0:response only)STATUS 11110000 F0
    System exclusive message
    ID No. 01000011 43
    Manufacturer's ID number (YAMAHA)
    SUB STATUS 0001nnnn 1n
    n=0-15 (Device number=MIDI Channel)
    GROUP ID 00111110 3E
    Digital mixer
    MODEL ID 00011001 19
    CL Series
    DATA CATEGORY 00000000 00
    OTHER DATA
    FUNCTION NAME 01001100 “L”
    (ASCII CODE)
    01101001 “i”
    (ASCII CODE)
    01100010 “b”
    (ASCII CODE)
    01000101 “E”
    (ASCII CODE)
    01111000 “x”
    (ASCII CODE)
    01101001 “i”
    (ASCII CODE)
    01110011 “s”
    (ASCII CODE)
    01110100 “t”
    (ASCII CODE)
    MODULE NAME 0mmmmmmm mm
    (ASCII CODE) 
     
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    DATA 0sssssss ss
    Data Status ( 0:Invalid data,1:Valid Data )
    0nnnnnnn nh
    Request Number High
    0nnnnnnn nl
    Request Number Low
    0ttttttt th
    Top Number High
    0ttttttt tl
    Top Number Low
    0eeeeeee eh
    End Number High
    0eeeeeee el
    End Number Low
    EOX 11110111 F7
    End of exclusive
    Module Name
    Number 
    						
    							 Data List
    41
    4.5.2 Format (PARAMETER REQUEST)
    ReceptionThe PARAMETER CHANGE will be sent with Device number [Rx CH] immediately 
    the data is received.4.5.3 Module Name
    4.6 FUNCTION CALL - COLLECTION STORE -4.6.1 Format (PARAMETER CHANGE)
    TransmissionData will be transmitted with the [Device Number] in [Tx CH] when [PARAMETER 
    CHANGE Tx] is on.4.6.2 Function Name
    4.6.3 Module Name
    4.7 FUNCTION CALL - MODULE -4.7.1 Format (PARAMETER CHANGE)
    ReceptionData will be received when [PARAMETER CHANGE Rx] is on and the Device 
    number of both [Rx CH] and SUB STATUS match.
    The data will be echoed when [PARAMETER CHANGE ECHO] is on.
    The corresponding effect will function immediately the data is received 
    (depending on the effect type).4.7.2 Module NameThis will not work when the Effect Type is different.
    STATUS 11110000 F0
    System exclusive message
    ID No. 01000011 43
    Manufacturer's ID number (YAMAHA)
    SUB STATUS 0011nnnn 3n
    n=0-15 (Device number=MIDI Channel)
    GROUP ID 00111110 3E
    Digital mixer
    MODEL ID 00011001 19
    CL Series
    DATA CATEGORY 00000000 00
    OTHER DATA
    FUNCTION NAME 01001100 “L”
    (ASCII CODE)
    01101001 “i”
    (ASCII CODE)
    01100010 “b”
    (ASCII CODE)
    01000101 “E”
    (ASCII CODE)
    01111000 “x”
    (ASCII CODE)
    01101001 “i”
    (ASCII CODE)
    01110011 “s”
    (ASCII CODE)
    01110100 “t”
    (ASCII CODE)
    MODULE NAME 0mmmmmmm mm
    (ASCII CODE) 
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    DATA 0nnnnnnn nh
    Request Number High
    0nnnnnnn nl
    Request Number Low
    EOX 11110111 F7
    End of exclusive
    Module Name
    Number
    SCENE LIB  “SCENE___” 1-300
    INPUT EQ LIB  “INEQ____” 41-200
    OUTPUT EQ LIB  “OUTEQ___” 4-200
    Dynamics LIB  “DYNA____” 42-200
    INPUT CH LIB “INCHNNL_” 1-200
    OUTPUT CH LIB “OUTCHNL” 1-200
    GEQ LIB “GEQ_____” 1-200
    8BandPEQ LIB “8PEQ____” 1-199
    EFFECT LIB “EFFECT__” 55-200
    Portico5033 LIB “P5033___” 1-100
    Portico5043 LIB “P5043___” 1-100
    U76 LIB “U76_____” 1-100
    Opt-2A LIB “OPT-2A__” 1-100
    EQP-1A LIB “EQ-1A___” 1-100
    DynamicEQ LIB “DYNAEQ__” 1-100
    Buss Comp 369 LIB “BSCMP369” 1-100
    Dante Input Patch LIB “DANTEIN_” 1-10
    STATUS 11110000 F0
    System exclusive message
    ID No. 01000011 43
    Manufacturer's ID number (YAMAHA)
    SUB STATUS 0001nnnn 1n
    n=0-15 (Device number=MIDI Channel)
    GROUP ID 00111110 3E
    Digital mixer
    MODEL ID 00011001 19
    CL Series
    DATA CATEGORY 00000000 00
    OTHER DATA
    FUNCTION NAME 01001100 “C”
    (ASCII CODE)
    01101001 “o”
    (ASCII CODE)
    01100010 “l”
    (ASCII CODE)
    01010101 “U”
    (ASCII CODE)
    01101110 “n”
    (ASCII CODE)
    01010011 “S”
    (ASCII CODE)
    01110100 “t”
    (ASCII CODE)
    01110010 “r”
    (ASCII CODE)
    MODULE NAME 0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    DATA 0nnnnnnn nh
    Number High
    0nnnnnnn nl
    Number Low
    0ccccccc ch
    Channel High
    0ccccccc cl
    Channel Low
    EOX 11110111 F7
    End of exclusive
    Function
    Number
    tx/rx
    “ColUnStr” Setup 0tx
    User Defined Key 0
    tx
    Program Change 0
    tx
    Control Change 0
    tx
    Module Name
    Mixer Setting “MIXERSET”
    Outport Setting “OUT_PORT”
    Monitor Setting “MONITOR_”
    MIDI Setting “MIDI_SET”
    Lib Number “LIB_NUM_”
    Program Change Table “PRGMCHG_”
    Control Change Table “CTRLCHG_”
    Preference (Current) “PREF_CUR”
    Preference (Admin) “PREF_ADM”
    Preference (Guest) “PREF_GST”
    User Defined Keys (Current) “UDEF_CUR”
    User Defined Keys (Admin) “UDEF_ADM”
    User Defined Keys (Guest) “UDEF_GST”
    Custom Fader Bank (Current) “CFAD_CUR”
    Custom Fader Bank (Admin) “CFAD_ADM”
    Custom Fader Bank (Guest) “CFAD_GST”
    User Level (Current) “UKEY_CUR”
    User Level (Guest) “UKEY_GST”STATUS 11110000 F0
    System exclusive message
    ID No. 01000011 43
    Manufacturer's ID number (YAMAHA)
    SUB STATUS 0001nnnn 1n
    n=0-15 (Device number=MIDI Channel)
    GROUP ID 00111110 3E
    Digital mixer
    MODEL ID 00011001 19
    CL Series
    DATA CATEGORY 00000000 00
    OTHER DATA
    FUNCTION NAME 01001101 “M”
    01101111 “o”
    01100100 “d”
    01000110 “F”
    01111000 “x”
    01010100 “T”
    01110010 “r”
    01100111 “g”
    MODULE NAME 0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    DATA 0eeeeeee ee
    Effect number (0:RACK1-7:RACK8)
    0ppppppp pp
    Release:0, Press:1
    EOX 11110111 F7
    End of exclusive
     Module Name
     Number
    Freeze Play button “FRZPLAY_” 0:RACK1, 2:RACK3, 4:RACK5, 6:RACK7
    Freeze Record button “FRZREC__” 0:RACK1, 2:RACK3, 4:RACK5, 6:RACK7
    Module Name 
    						
    							 Data List
    42
    4.8  FUNCTION CALL - CHANNEL -4.8.1 Pair ON/OFF Trigger Format (PARAMETER CHANGE)
    ReceptionData will be received when [PARAMETER CHANGE Rx] is on and the Device 
    number of both [Rx CH] and SUB STATUS match.
    The data will be echoed when [PARAMETER CHANGE ECHO] is on.4.8.2 Module Name
    *1) 0:CH1 - 71:CH72
    256:MIX 1 - 279:MIX 24
    512:MATRIX 1-519:MATRIX 8
    4.9 LEVEL METER DATA4.9.1 Format (PARAMETER CHANGE)When transmission is enabled by receiving Request for Level Meter, the 
    corresponding metering data will be sent in every 50 millisecond for 10 seconds. 
    If metering information is expected to be continuously sent, Request is needed to 
    be sent in at least every 10 seconds.ReceptionThe data will be echoed when [PARAMETER CHANGE ECHO] is on.TransmissionWhen transmission is enabled by receiving Request, the corresponding metering 
    data will be sent in constant interval for a given period of time (The interval and 
    time will vary depending on devices).
    When rebooted or port setting is changed, the transmission will be disabled.
    When [PARAMETER CHANGE ECHO] is on, the message will be sent as it is.4.9.2 Format (PARAMETER REQUEST)
    ReceptionData will be received when [PARAMETER CHANGE Rx] is on and the Device 
    number of both [Rx CH] and SUB STATUS match.
    The data will be echoed when [PARAMETER CHANGE ECHO] is on.
    The corresponding metering data will be sent via [Rx CH] in constant interval for 
    a given period of time (The interval and time will vary depending on devices).
    If this is received with an Address UL = 0x7F, transmission of all meter data will 
    stop (will be disabled) immediately.TransmissionWhen [PARAMETER CHANGE ECHO] is on, the message will be sent as it is.
    STATUS 11110000 F0
    System exclusive message
    ID No. 01000011 43
    Manufacturer's ID number (YAMAHA)
    SUB STATUS 0001nnnn 1n
    n=0-15 (Device number=MIDI Channel)
    GROUP ID 00111110 3E
    Digital mixer
    MODEL ID 00011001 19
    CL Series
    DATA CATEGORY 00000000 00
    OTHER DATA
    FUNCTION NAME 01000011 “C”
    01101000 “h”
    01101100 “l”
    01010000 “P”
    01101001 “i”
    01110010 “r”
    01000011 “C”
    01110000 “p”
    MODULE NAME 0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    0mmmmmmm mm
    (ASCII CODE)
    DATA 0sssssss sh
    Source Channel Number H *1)
    0sssssss sl
    Source Channel Number L *1)
    0ddddddd dh
    Destination Channel Number H *1)
    0ddddddd dl
    Destination Channel Number L *1)
    EOX 11110111 F7
    End of exclusive
     Module Name
    Pair On (with Copy) “PAIRONCP”
    Pair On (with Reset Both) “PAIRONRS”
    Pair Off “PAIROFF_”
    STATUS 11110000 F0
    System exclusive message
    ID No. 01000011 43
    Manufacturer's ID number (YAMAHA)
    SUB STATUS 0001nnnn 1n
    n=0-15 (Device number=MIDI Channel)
    GROUP ID 00111110 3E
    Digital mixer
    MODEL ID 00011001 19
    CL Series
    DATA CATEGORY 00100001 21
    REMOTE LEVEL METER
    DATA 0mmmmmmm mm
    ADDRESS UL
    0mmmmmmm mm
    ADDRESS LU
    0mmmmmmm mm
    ADDRESS LL
    0ddddddd dd
    Data1
    ::
    EOX 11110111 F7
    End of exclusive
    STATUS 11110000 F0
    System exclusive message
    ID No. 01000011 43
    Manufacturer's ID number (YAMAHA)
    SUB STATUS 0011nnnn 3n
    n=0-15 (Device number=MIDI Channel)
    GROUP ID 00111110 3E
    Digital mixer
    MODEL ID 00011001 19
    CL Series
    DATA CATEGORY 00100001 21
    REMOTE LEVEL METER
    DATA 0mmmmmmm mm
    ADDRESS UL
    0mmmmmmm mm
    ADDRESS LU
    0mmmmmmm mm
    ADDRESS LL
    0ccccccc ch
    Count H
    0ccccccc cl
    Count L
    EOX 11110111 F7
    End of exclusive 
    						
    							 Data List
    43 Input/output characteristics
    ANALOG INPUT CHARACTERISTICS
    *1. Sensitivity is the lowest level that will produce an output of +4dBu (1.23V) or the nominal 
    output level when the unit is set to maximum gain. (all faders and level controls are 
    maximum position.)
    *2. XLR-3-31 type connectors are balanced. (1= GND, 2= HOT, 3= COLD)
    * In these specifications, 0dBu= 0.775 Vrms.
    * All input AD converters are 24bit linear, 128times oversampling.
    * +48V DC ( phantom power ) is supplied to ONI IN (1-8) and TALKBACK XLR type 
    connectors via each individual software controlled switches.
    ANALOG OUTPUT CHARACTERISTICS
    *1. XLR-3-32 type connectors are balanced. (1= GND, 2= HOT, 3= COLD)
    *2. PHONES stereo phone jack is unbalanced. (Tip= LEFT, Ring= RIGHT, Sleeve= GND)
    *3. There are switches inside the body to preset the maximum output level.
    *4. The position of the level control is 10dB lowered from Max.
    * In these specifications, 0dBu= 0.775 Vrms.
    * All output DA converters are 24bit, 128times oversampling.
    DIGITAL INPUT & OUTPUT CHARACTERISTICS
    DIGITAL OUTPUT CHARACTERISTICS
    *1. Channel Status of DIGITAL OUT
    *2. XLR-3-32 type connectors are balanced. (1= GND, 2= HOT, 3= COLD) Input 
    Te r m i n a l sGAIN
    Actual 
    Load 
    ImpedanceFor Use 
    With 
    Nominal
    Input Level
    Connector
    Sensitivity
    *1
    NominalMax. before 
    clip
    OMNI IN 
    1-8+66dB
    7.5kΩ50-600Ω 
    Mics & 
    600Ω 
    Lines-82dBu 
    (61.6μV)-62dBu 
    (0.616mV)-42dBu 
    (6.16mV)
    XLR-3-31 type 
    (Balanced)
    *2
    -6dB-10dBu 
    (245mV)+10dBu 
    (2.45V)+30dBu 
    (24.5V)
    TALKBACK+64dB
    10kΩ50-600Ω 
    Mics & 
    600Ω 
    Lines-70dBu 
    (0.245mV)-60dBu 
    (0.775mV)-40dBu 
    (7.75mV)
    XLR-3-31 type 
    (Balanced)
    *2
    +20dB-26dBu 
    (38.8mV)-16dBu 
    (0.123V)+4dBu 
    (1.23V)
    Output 
    Te r m i n a l sActual 
    Source 
    Impedanc
    e
    For Use 
    With 
    Nominal
    GAIN 
    SW
    *3
    Output Level
    Connector
    NominalMax. before 
    clip
    OMNI 
    OUT 1-875Ω600Ω 
    Lines+24dB 
    (default)+4dBu 
    (1.23V)+24dBu 
    (12.3V)
    XLR-3-32 type 
    (Balanced)
    *1
    +18dB-2dBu 
    (616mV)+18dBu 
    (6.16V)
    PHONES 15Ω8Ω 
    Phones-
    75mW
    *4
    150mW
    Stereo Phone Jack 
    (TRS) 
    (Unbalanced)
    *2
    40Ω 
    Phones-
    65mW
    *4
    150mW
    Terminal FormatData 
    lengthLevel Audio Connector
    Primary/
    SecondaryDante24bit or 
    32bit1000Base
    -T64ch Input/64ch Output 
    @48kHzEtherCON Cat5e
    Terminal FormatData 
    LengthLevel Connector
    DIGITAL 
    OUT
    *1
    AES/EBU
    AES/EBU Professional Use24bit RS422
    XLR-3-32 type (Balanced)
    *2
    Byte Bit Field Name Fixed/Variable Data Description
    00 Block Format
    fixed1 professional use
    1Mode 0 audio
    2-4 Emphasis 0x4 off
    5 Fs Lock 0 lock
    6-7 Sampling Frequency variable0x0 others
    0x3 32 kHz
    0x2 44.1 kHz
    0x1 48 kHz
    10-3 Channel Mode
    fixed0x1 2ch mode
    4-7 Users Bit Management 0x0 -
    20-2 Use of AUX
    fixed0x1 24 bits Audio Data
    3-7 Source 0x00 -
    3 0-7 Multi Channel fixed 0x00 -
    40-1 Digital Audio Reference Signal
    fixed0x0
    -
    2- 0
    3-6 Sampling Frequency variable 0x0 others
    7 Sampling Frequency Scan Flag fixed 0 - 
    						
    							 Data List
    44
    I/O SLOT (1-3) CHARACTERISTICSEach I/O Slot accepts a mini-YGDAI card. Only Slot1 has a serial interface.CONTROL I/O CHARACTERISTICS
    *1. Input pin: TTL level, w/ internal pull-up (47kΩ)
    Output pin: Open drain output (Vmax=12V, maximum sink current/pin=75mA)
    Power supply pin: Output voltage Vp=5V, Max. output current Imax=300mA
    *2. 4 pin=+12V, 3 pin=GND, Lamp rating 5W. Voltage control by software.Terminal Format Level Connector
    MIDIIN MIDI - DIN Connector 5P
    OUT MIDI - DIN Connector 5P
    WORD 
    CLOCKIN - TTL/75Ω terminated BNC Connector
    OUT - TTL/75Ω BNC Connector
    GPI (5IN/5OUT) - -D Sub Connector 15P 
    (Female)
    *1
    NETWORK IEEE802.3 10BASE-T/100Base-TX RJ-45
    LAMP (CL5:  x3, CL3:  
    x2, CL1:  x1)-
    0V-12V
    *2
    XLR-4-31 type
    *2
    USB HOST USB 2.0 - USB A Connector (Female)
    DC POWER INPUT - - JL05 Connector
    METER (CL3/CL1 only) - -D Sub Connector 9P 
    (Female) 
    						
    							 Data List
    45 Electrical Characteristics
    All faders are nominal when measured. Output impedance of signal generator:150ohms
    Frequency Response. 
    Fs= 44.1 kHz or 48 kHz @20 Hz-20 kHz, referenced to 
    the nominal output level @1 kHz
    
    Total Harmonic Distortion. 
    Fs= 44.1 kHz or 48 kHz
    * Total Harmonic Distortion is measured with a 18 dB/octave filter @80 kHz
    Hum & Noise. 
    Fs= 44.1 kHz or 48 kHz, EIN= Equivalent Input Noise
    * Hum & Noise are measured with A-weight filter.
    Dynamic Range. 
    Fs= 44.1 kHz or 48 kHz
    * Dynamic Range are measured with A-weight filter.
    
    Sampling Frequency
    Input
    Output
    RL
    Conditions
    Min.
    Typ.
    Max.
    Unit
    OMNI IN 1-8OMNI OUT 1-8 600 Ω
    GAIN:  +66dB-1.5 0.0 0.5
    dB
    PHONES 8 Ω -3.0  0.0  0.5
    Input
    Output
    RL
    Conditions
    Min.
    Typ.
    Max.
    Unit
    OMNI IN 1-8 OMNI OUT 1-8 600 Ω+4 dBu @20 Hz-20 kHz, GAIN:  +66dB 0.1
    % +4 dBu @20 Hz-20 kHz, GAIN:  -6dB 0.05
    Internal OSCOMNI OUT 1-8 600 Ω Full Scale Output @1 kHz 0.02
    PHONES 8 ΩFull Scale Output @1 kHz, PHONES Level 
    Control:  Max.0.2
    Input
    Output
    RL
    Conditions
    Min.
    Typ.
    Max.
    Unit
    OMNI IN 1-8 OMNI OUT 1-8 600 ΩRs= 150 Ω, GAIN:  +66dB
    Master fader at nominal level and one 
    Ch fader at nominal level. -128
    EIN
    dBu -62
    Rs= 150 Ω, GAIN:  -6dB
    Master fader at nominal level and one 
    Ch fader at nominal level. -84 -79
    All INPUTs  OMNI OUT 1-8 600 ΩRs= 150 Ω, GAIN:  -6dB
    Master fader at nominal level and all 
    OMNI IN 1-8 in faders at nominal level.-70
    - OMNI OUT 1-8 600 Ω Residual Output Noise, ST Master Off -88
    -PHONES 8 ΩResidual Output Noise, PHONES Level 
    Control Min.-88
    Input
    Output
    RL
    Conditions
    Min.
    Typ.
    Max.
    Unit
    OMNI IN 1-8 OMNI OUT 1-8 600 Ω AD + DA, GAIN:  -6dB 108 dB
    - OMNI OUT 1-8 600 Ω DA Converter 112 dB
    Parameter
    Conditions
    Min.
    Typ.
    Max.
    Unit
    External ClockFrequency 
    Range Fs= 44.1 kHz
    Fs= 45.9375 kHz (44.1 kHz +4.1667%)
    Fs= 44.1441 kHz (44.1 kHz +0.1%)
    Fs= 44.0559 kHz (44.1 kHz -0.1%)
    Fs= 42.336 kHz (44.1 kHz -4.0%) 
    -200 +200 ppm
    Fs= 48 kHz
    Fs= 50 kHz (48 kHz +4.1667%)
    Fs= 48.048 kHz (48 kHz +0.1%)
    Fs= 47.952 kHz (48 kHz -0.1%)
    Fs= 46.080 kHz (48 kHz -4.0%)
    Jitter of PLLDIGITAL IN Fs= 44.1 kHz
    DIGITAL IN Fs= 48 kHz10 ns
    Internal ClockFrequencyWord Clock : Int 44.1 kHz 44.1
    kHz
    Word Clock : Int 48 kHz 48
    AccuracyWord Clock : Int 44.1 kHz
    -50 +50 ppm
    Word Clock : Int 48 kHz
    JitterWord Clock : Int 44.1 kHz 4.429
    ns
    Word Clock : Int 48 kHz 4.069 
    						
    							 Data List
    46 Mixer Basic Parameters
    
    Libraries
    
    Input Function
    
    Output Function
    
    Output Port
    
    Processor
    Name
    Number
    To t a l
    Scene Memory Preset 1 + User 300 301
    Input CH Library Preset 1 + User 199 200
    Output CH Library Preset 1 + User 199 200
    Input EQ Library Preset 40 + User 159 199
    Output EQ Library Preset 3 + User 196 199
    Dynamics Library Preset 41 + User 158 199
    Effect Library Preset 27 + User 172 199
    GEQ Library Preset 1 + User 199 200
    Premium Rack Library
    Portico5033
    Portico5043
    U76
    Opt-2A
    EQ-1A
    Dynamic EQPreset 1 + User 199 200
    Dante Input Patch Library Preset 1 + User 10 11
    Function
    Parameter
    Phase Normal/Reverse
    Digital Gain -96 dB to +24 dB
    L,R-MONO L-MONO/R-MONO/LR-MONO/STEREO IN
    HPFSlope= -12dB/Oct, -6dB/Oct
    Frequency= 20 Hz to 600 Hz
    Attenuator -96 dB to 0 dB
    4 Band 
    EqualizerFrequency= 20 Hz to 20 kHz
    Gain= -18 dB to +18 dB
    Q= 0.10 to 10.0
    Low Shelving (Low Band)
    High Shelving, LPF (High Band)
    Type I/Type II
    Insert Insert Point:  Pre EQ/Pre Fader/Post On
    Direct Out Direct Out Point:  Pre HPF/Pre EQ/Pre Fader/Post On
    Dynamics 1Type:  Gate/Ducking/Comp/Expander
    Threshold=Gate:  -72 dB to 0 dB
    Others:  -54 dB to 0 dB
    Ratio= 1:1 to ∞:1
    Attack= 0 msec to 120 msec
    Hold= 48 kHz:  0.02 msec to 1.96 sec
    44.1 kHz:  0.02 msec to 2.13 sec
    Decay= 48 kHz:  5 msec to 42.3 sec
    44.1 kHz:  6 msec to 46.1 sec
    Dynamics 1Releace= 48 kHz:  5 msec to 42.3 sec
    44.1 kHz:  6 msec to 46.1 sec
    Range= Gate:  -∞ dB to 0 dB
    Ducking:  -70 dB to 0 dB
    Gain= 0.0 dB to +8dB
    Knee= Hard to 5 (soft)
    Key In:  Self Pre EQ/Self Post EQ/Mix Out21-24
    Ch1-STIN8R (8ch block)
    Key In Filter:  HPF/LPF/BPF
    Dynamics2Type:  Comp/De-Esser/Compander H/Compander S
    Threshold= -54 dB to 0 dB
    Ratio= 1:1 to ∞:1
    Compander:  1:1 to 20:1
    Attack= 0 msec to 120 msec
    Release= 48 kHz:  5 msec to 42.3 sec
    44.1 kHz:  6 msec to 46.1 sec
    Gain= -18 dB to 0 dB, 0 dB to +18 dB
    Knee= Hard to 5 (soft)
    Key In:  Self Pre EQ/Self Post EQ/Mix Out21-24 
    Ch1-STIN8R (8ch block)
    Width= 1 dB to 90 dB
    Frequency= 1.0 KHz to 12.5KHz
    TYPE= HPF, BPF
    Q= 0.10 to 10.0
    Fader Level:  1024 steps, ∞, -138 dB to +10 dB
    On On/Off
    Pan/BalancePosition L63 to R63
    Pan Mode:  Pan/Balance
    DCA Group 16 Groups
    Mute Group 8 Groups
    Mix Send24 sends
    Fix/Variable can be set each two mixes 
    (Surround Pan can be set 1 to 6 mixes)
    Mix Send Point:  Pre EQ/Pre Fader/Post On
    Level:  1024 steps, ∞, -138 dB to +10 dB 
    (Position L63 to R63, R63 to F63 for Surround)
    Matrix Send8 Sends
    Matrix Send Point:  Pre EQ/Pre Fader/Post On
    Level:  1024 steps, ∞, -138 dB to +10 dB
    LCR Pan CSR= 0% to 100%
    DELAY 0 ms to 1000 msec
    Function
    Parameter
    Attenuator -96 dB to 0 dB
    Function
    Parameter
    4 Band 
    EqualizerFrequency= 20 Hz to 20 kHz
    Gain= -18 dB to +18 dB
    Q= 0.10 to 10.0
    Low Shelving (Low Band)
    High Shelving, LPF (High Band)
    Type I/Type II
    Insert Insert Point:  Pre EQ/Pre Fader/Post On
    Dynamics 1Type:  Comp/Expander/Compander H/Compander S
    Threshold= -54 dB to 0 dB
    Ratio= 1:1 to ∞:1
    Compander:  1:1 to 20:1
    Attack= 0 msec to 120 msec
    Release= 48 kHz:  5 msec to 42.3 sec
    44.1 kHz:  6 msec to 46.1 sec
    Gain= -18 dB to 0 dB, 0 dB to +18 dB
    Knee= Hard to 5 (soft)
    Key In:  Self Pre EQ/Self Post EQ/Mix Out21-24 MIX24/
    MTRX1-8/STIN LR/MONO(C) (8ch block)
    Width= 1 dB to 90 dB
    Fader Level:  1024 steps, ∞, -138 dB to +10 dB
    On On/Off
    Pan/Balance Position L63 to R63
    DCA Group 16 Groups
    Mute Group 8 Groups
    Mix to Matrix 
    Stereo to MatrixMatrix Send Point:  Pre Fader/Post On
    Level:  1024 steps, ∞, -138 dB to +10 dB
    OscillatorLevel= 0 to -96dB (1 dB step)
    On/Off= Software control
    Function
    Parameter
    Out Port Delay 0 msec to 1000 msec
    Out Port Phase Normal/Reverse
    Gain -96 to +24 dB
    Function
    Parameter
    GEQ 31 bands x 16(24) or 15 bands x 32(48) systems
    PEQ (8 bands PEQ + 3 notchs + HPF, LPF) x 32(48) systems
    AUTOMIXER 8(16) channels
    Effects Stereo In/Stereo Out multi effector x 8 systems
    Premium Rack 
    ParameterStereo(Dual) In/Stereo(Dual) Out Premium Rack x 
    8systems
    Function
    Parameter 
    						
    							 Data List
    47 Pin Assignment
    DC POWER INPUT GPI METER (CL3/CL1 only)
    Pin Signal Name Pin Signal Name
    1+24V13GND
    2+24V14GND
    3+24V15GND
    4+24V16GND
    5+24V17GND
    6+24V18GND
    7+24V19CAUTION(+)
    8 +24V 20 CAUTION(-)
    9 +24V 21 DETECT A
    10 GND 22 DETECT B
    11 GND 23 DETECT GND
    12 GND Frame GND
    1
    2
    3 4
    5 6 7 8 9
    10 11 12 13 14
    15
    16
    17 18 19 20
    21
    22 23
    Pin Signal Name Pin Signal Name
    1GPO19GPO2
    2GPO310GPO4
    3GPO511GND
    4GND12GND
    5 +5V 13 +5V
    6 GPI114GPI2
    7 GPI315GPI4
    8GPI5
    9
    10
    11 8
    1
    2
    3
    15
    Pin Signal Name Pin Signal Name
    1 RESET 6 +3.3LD
    2 SDA 7 +3.3LD
    3 DGND 8 LDGND
    4SCL9LDGND
    5+3.3D
    1