Page 71

Channel Job
 Reference Manual
71
2
Mute group assign field
This area displays the channels assigned to the currently-selected mute group.
While this window is displayed, press the [SEL] key for the channel that you want to 
assign to the mute group. The channel will be assigned to the mute group, and the on-
screen fader for that channel will turn red. Press the same [SEL] key once again if you 
want to remove the channel from the group.
If the MUTE SAFE button is on, this field displays the channels...

Page 72

Channel Job
 Reference Manual
72
Using mute groupsTo control mute groups, you can use the MUTE GROUP MASTER buttons in the MUTE 
GROUP ASSIGN window. In addition, it may prove convenient if you assign the Mute On/Off 
function for a mute group 1 - 8 to a USER DEFINED key.Assigning mute groups to USER DEFINED keys
NOTEThe USER SETUP window enables you to limit available functionality by user, and also to make 
system-wide settings. This window includes several pages, which you can switch between using...

Page 73

Channel Job
 Reference Manual
73
NOTEThe [SEL] key of the channel set for Mute Safe will light, and the on-screen fader for that channel 
will be highlighted in green. You can cancel the Mute Safe status by pressing a lit [SEL] key once 
again to make it go dark.
Using the temporary unmute functionIf one of the mute group master buttons on a channel is ON, press the [ON] key for that 
channel to temporarily unmute the channel. However, in PREVIEW mode, any operation 
during mute with pressing of the [ON]...

Page 74

Channel Job
 Reference Manual
74
RECALL SAFE MODE window1
CLEAR ALL button/SET ALL button
The CLEAR ALL button turns off (disables) the Recall Safe function (that is currently set 
for individual channels) and the Global Recall Safe function simultaneously. The SET ALL 
button turns on (enables) these functions simultaneously.
NOTEIf you press the CLEAR ALL button, the Recall Safe function will temporarily be disabled. 
However, the parameters that would be affected by the Recall Safe function will not...

Page 75

Channel Job
 Reference Manual
75
• Input channel
NOTE
ST IN channels do not feature INSERT, INSERT PATCH, and DIRECT OUT button.
• MIX channel
• MATRIX channel
• STEREO channel
• MONO channel
I f  R e c a l l  S a f e  i s  t u r n e d  o n  f o r  g l o b a l  p a r a m eters, the safe parameter select buttons of the 
selected channel will light green, as follows.
This figure indicates that the INPUT PATCH, INSERT PATCH, and DIRECT OUT 
parameters have been set to Safe by the INPUT PATCH Global...

Page 76

Channel Job
 Reference Manual
76
9
Safe parameter select button (DCA)
For each DCA group, selects the parameters for which Recall Safe is enabled. If the ALL 
button is on, all DCA master parameters will be subject to Recall Safe. If LEVEL/ON is on, 
Recall Safe will apply to the DCA master level and on/off status. If NAME is on, Recall 
Safe will apply to the DCA group name. Although you can turn on both the LEVEL/ON 
button and the NAME button, they will then both be switched off if you turn on the ALL...

Page 77

Channel Job
 Reference Manual
77
NOTE• You can also access the CH LINK MODE window by simultaneously pressing and then releasing 
the [SEL] keys of two or more channels that will be linked.
• When you press the [SEL] key for a channel (that belongs to a link group) to make it light, the 
[SEL] keys of all channels that belong to the same link group will blink.
• If you link an input channel to a ST IN channel, parameters that do not exist for a ST IN channel 
will be ignored.
CH LINK MODE window (input...

Page 78

Channel Job
 Reference Manual
78
3
LINK PARAMETER field
Use the buttons in this field to select the parameters that you want to be linked. You can 
do this independently for each link group.
The table below lists the parameters you can select in the LINK PARAMETER field.
NOTE• If you link Dynamics 1 or 2 for two or more input channels, the parameter values will be linked, 
but the key-in sources are not linked and can instead be set for each channel. The behavior of 
key-in signals is linked in units of...

Page 79

Channel Job
 Reference Manual
79
CH LINK MODE window (output channels)You can view the output channels that are linked and specify the parameters that will be 
linked.1
Output channel display field
When you create a link group, the corresponding output channels will be highlighted. 
If there are two or more link groups, each group is shown in a different color. Press this 
field to open the CH LINK SET window. You can also link output channels in this window.
NOTEIn the case of the CL3 and CL1, faders...

Page 80

Channel Job
 Reference Manual
80
Channel link operations
• Linking three or more channels
Hold down the link-source [SEL] key and successively press the [SEL] key of each output 
channel you want to add to the link group.
• Adding a new channel to an existing link group
Hold down any [SEL] key within the group and press the [SEL] key that you want to add 
to the group.
NOTE
If the link-destination output channel is already assigned to another link group, its assignment to 
the previous group will be...