Page 71
Channel Job Reference Manual 71 2 Mute group assign field This area displays the channels assigned to the currently-selected mute group. While this window is displayed, press the [SEL] key for the channel that you want to assign to the mute group. The channel will be assigned to the mute group, and the on- screen fader for that channel will turn red. Press the same [SEL] key once again if you want to remove the channel from the group. If the MUTE SAFE button is on, this field displays the channels...
Page 72
Channel Job Reference Manual 72 Using mute groupsTo control mute groups, you can use the MUTE GROUP MASTER buttons in the MUTE GROUP ASSIGN window. In addition, it may prove convenient if you assign the Mute On/Off function for a mute group 1 - 8 to a USER DEFINED key.Assigning mute groups to USER DEFINED keys NOTEThe USER SETUP window enables you to limit available functionality by user, and also to make system-wide settings. This window includes several pages, which you can switch between using...
Page 73
Channel Job Reference Manual 73 NOTEThe [SEL] key of the channel set for Mute Safe will light, and the on-screen fader for that channel will be highlighted in green. You can cancel the Mute Safe status by pressing a lit [SEL] key once again to make it go dark. Using the temporary unmute functionIf one of the mute group master buttons on a channel is ON, press the [ON] key for that channel to temporarily unmute the channel. However, in PREVIEW mode, any operation during mute with pressing of the [ON]...
Page 74
Channel Job Reference Manual 74 RECALL SAFE MODE window1 CLEAR ALL button/SET ALL button The CLEAR ALL button turns off (disables) the Recall Safe function (that is currently set for individual channels) and the Global Recall Safe function simultaneously. The SET ALL button turns on (enables) these functions simultaneously. NOTEIf you press the CLEAR ALL button, the Recall Safe function will temporarily be disabled. However, the parameters that would be affected by the Recall Safe function will not...
Page 75
Channel Job Reference Manual 75 • Input channel NOTE ST IN channels do not feature INSERT, INSERT PATCH, and DIRECT OUT button. • MIX channel • MATRIX channel • STEREO channel • MONO channel I f R e c a l l S a f e i s t u r n e d o n f o r g l o b a l p a r a m eters, the safe parameter select buttons of the selected channel will light green, as follows. This figure indicates that the INPUT PATCH, INSERT PATCH, and DIRECT OUT parameters have been set to Safe by the INPUT PATCH Global...
Page 76
Channel Job Reference Manual 76 9 Safe parameter select button (DCA) For each DCA group, selects the parameters for which Recall Safe is enabled. If the ALL button is on, all DCA master parameters will be subject to Recall Safe. If LEVEL/ON is on, Recall Safe will apply to the DCA master level and on/off status. If NAME is on, Recall Safe will apply to the DCA group name. Although you can turn on both the LEVEL/ON button and the NAME button, they will then both be switched off if you turn on the ALL...
Page 77
Channel Job Reference Manual 77 NOTE• You can also access the CH LINK MODE window by simultaneously pressing and then releasing the [SEL] keys of two or more channels that will be linked. • When you press the [SEL] key for a channel (that belongs to a link group) to make it light, the [SEL] keys of all channels that belong to the same link group will blink. • If you link an input channel to a ST IN channel, parameters that do not exist for a ST IN channel will be ignored. CH LINK MODE window (input...
Page 78
Channel Job Reference Manual 78 3 LINK PARAMETER field Use the buttons in this field to select the parameters that you want to be linked. You can do this independently for each link group. The table below lists the parameters you can select in the LINK PARAMETER field. NOTE• If you link Dynamics 1 or 2 for two or more input channels, the parameter values will be linked, but the key-in sources are not linked and can instead be set for each channel. The behavior of key-in signals is linked in units of...
Page 79
Channel Job Reference Manual 79 CH LINK MODE window (output channels)You can view the output channels that are linked and specify the parameters that will be linked.1 Output channel display field When you create a link group, the corresponding output channels will be highlighted. If there are two or more link groups, each group is shown in a different color. Press this field to open the CH LINK SET window. You can also link output channels in this window. NOTEIn the case of the CL3 and CL1, faders...
Page 80
Channel Job Reference Manual 80 Channel link operations • Linking three or more channels Hold down the link-source [SEL] key and successively press the [SEL] key of each output channel you want to add to the link group. • Adding a new channel to an existing link group Hold down any [SEL] key within the group and press the [SEL] key that you want to add to the group. NOTE If the link-destination output channel is already assigned to another link group, its assignment to the previous group will be...