    Chapter 3 Basic Operation
    Commands batch processing : Available CommandItems Description
    Power ON/OFF ......................... 
    Sets up the Power ON or Power OFF.Input,Source .............................. Sets up the Input and Source. Selects Input and Source.Screen ....................................... 
    Sets up the screen size. Resizes the picture screen.Background ............................... Sets up the background. Selects the background screen for when no input signal is detected.Display ........................................ Sets up the Display. Decides whether to display On-Screen Displays or not.Shutter(No show) .................... Sets up the Shutter (No show). Sets black out the image.Lamp control ............................. Sets up the Lamp control. Changes brightness of the screen.Fan control ................................. Sets up the Fan control. Chooses the running speed of cooling fans.
    Setting timer for targets
    The timer information for targets can be set up by the procedure below.
    1  Choose a target which you want to set the timer.
    2  Select Timer setting from Target menu. Timer selection dialog box will appear as the 
    below figure. Check in a check box of an event to carry out.
    3  When you want to add events, click Add button. Input timer informations in Timer set-
    ting dialog box, and click OK button.
    4  Click OK button of Timer selection dialog box, timers are set to the selected target. 
    When selecting multiple targets, timers are set to all the selected targets.
    TimerItems Description
    Execution date ......................... 
    Sets up the Timer execution date.  (everyday or a day)Execution time .......................... Sets up the Timer execution time. (hh:mm:ss)Action ....................................... 
    Sets up the events.  
    						
    							17
    Setting up default setting
    The monitoring information and e-mail information can be set up by the procedure below.
    1  Select System default setting from System menu. The setting window will appear.
    2  Switch by clicking Monitoring information or E-mail information tab for each setting.
    Monitoring informationItems Description
    Monitoring interval ................ 
    Sets up the interval of the polling in minute unit. (1 to 99 minutes can be set)Temperature unit ..................... Sets up the display temperature unit Centigrade or Fahrenheit.Event reception process.......... 
    Sets up the treatment when the event (ALERT, TRAP, SYSERR) happens on the target. For further information, refer to the item "About event treatment" (+p.26). p Sound warning alarm p Send e-mail p Display warning dialog
    Monitoring information
    Setting up default setting  
    						
    							18
    Chapter 3 Basic Operation
    E-mail informationItems Description
    SMTP server ..................... 
    Sets up the IP address of SMTP mail server or server host name.Administrator'smail address ...................... Sets up the e-mail address of administratorDestination mail address ................................ 
    Sets up the destination mail address when the event (ALERT, TRAP, SYSERR) happens on the target. The mail address entering window appears when clicking Add button.
    E-mail information
    0  If Send e-mail check box of Event reception process on Monitoring information is un-checked, the alert e-mail will not be sent even if you set up the e-mail address.
    0  Up to 10 addresses can be set up for the destination mail address.0  For the contents of the mail, refer to item "About event treatment" (+p.26).  
    						
    							19
    Customizing the status list
    Changing the status column indication
    1  Select Column selection from System menu. The col-
    umn selection window will appear.
    2  
    On the window, check the column name to be indi-
    cated on the status list.
    0  
    The mark [*] next to the column name indicates alert item.
    3  
    To change the order of the display column on the 
    status list, select a column you intend to change the 
    order and click To up or To down button.
    4 Click OK to close setting.
    0  When specifying the column width by numeric value, enter number (0 to 9999) onto "Column width" text box.
    Column Description
    *Target name ............................Name of the network equipment*Group ...........................................Group name*Connect ......................................Status of connection to the network (Connected, Un-connected)*Drive time .................................Accumulated use time of the equipment*Power status ............................ 
    Power status of the equipment (Normal(Power-on), Normal(Standby), Power Management, Power failure, lamp failure, etc.)*Input status ..............................Input signal status (Signal, No signal, Signal interrupted)*Inside Temperature   A status ....................................Status of inside temperature A (Normal, Warning, Error)*Inside Temperature  B status ....................................Status of inside temperature B (Normal, Warning, Error)*Inside Temperature  C status ....................................Status of inside temperature C (Normal, Error)*External Temperature   status.........................................Status of external temperature  (Normal, Warning, Error)*Lamp1 status ..........................Status of Lamp1 (Off, On, Error, Replace)*Lamp2 status ..........................Status of Lamp2 (Off, On, Error, Replace)*Lamp3 status ..........................Status of Lamp3 (Off, On, Error, Replace)*Lamp4 status ..........................Status of Lamp4 (Off, On, Error, Replace)*Lamp1 time..............................Used time of Lamp1*Lamp2 time..............................Used time of Lamp2*Lamp3 time..............................Used time of Lamp3*Lamp4 time..............................Used time of Lamp4*Filter status ...............................Status of airfilter (Normal, Clogged)*Option Box filter status ............................Status of option box filter (Normal, Error, Clogged)*Filter time ..................................Use time of airfilter*Option Box filter time ................................Use time of option box filter
    0  The values in parentheses are typical value and they differ depending on the connected equipment.
    0  
    The [*] next to the column name indicates alert items.
    Customizing the status list
    Specifies col-umn width  
    						
    							20
    Chapter 3 Basic Operation
    Column Description
    *Error info. ...................................Error information (Not available for the projector)IP address ....................................IP address of the network equipmentCommunity ................................Community name of the network equipment (public)Introduction date*1 ...............Date of the network equipment installedTimer ...............................................Timer informationProduct info. ..............................Name of the network equipment System name ............................System name of the network equipment (Proj_05)Contact ..........................................Contact information of the network equipmentLocation ........................................Installed location of the network equipmentInput signal ................................Information of the input mode (Input1, Input2, etc.)Input select ................................Information of the input source (RGB, VIDEO, S-VIDEO, NETWORK, etc.)Network status.........................Condition of the network mode (Off line, Network Viewer, Network Capture)Audio system ............................Displays audio system mode (NORMAL, PERSONAL, MUSIC, TALK)Volume ..........................................Sound Volume of the network equipment Treble ..............................................Sound treble of the network equipmentBass ..................................................Sound bass of the network equipmentBalance ..........................................Sound balance of the network equipment Mute ................................................Sound mute status of the network equipment (ON, OFF)Power management ............ 
    Power management status of the network equipment (OFF, READY, SHUTDOWN)Monitor out ................................Monitor out status of the network equipment (ON, OFF)Shutter (No show) .................Shutter status of the network equipment (OFF, High-Contrast, Normal)Shutter management .........Shutter management status of the network equipment (Shutdown)Fan control ..................................Fan control status of the network equipment (Normal, Maximum, OFF, On1, etc. )Inside Temperature A ..........Displays inside temperature A of the equipment (in Centigrade or Fahrenheit)Inside Temperature B ..........Displays inside temperature B of the equipment (in Centigrade or Fahrenheit)Inside Temperature C ..........Displays inside temperature C of the equipment (in Centigrade or Fahrenheit)External Temperature .........Displays external temperature of the equipment (in Centigrade or Fahrenheit)Lamp mode ................................Displays lamp mode (1: 1-lamp mode, 2: 2-lamp mode, 4: 4-lamp mode, etc.)Lamp control .............................Displays lamp control mode (Auto, Normal, Eco, etc.)Model name ..............................Model name of the network equipment
    *1 Set up the installed date when the PJ Network Manager is newly introduced.
    0    
    There are some un-available columns depending on the products. The value of un-available col-umn is displayed in blank or with "---".  
    						
    							21
    Changing font
    Select Font setting from System menu. The font setup window will appear. Select your 
    desired type face, style and size on the window.
    0  Customized font property is applied to all the windows of the setting.
    To change order or width of the column
    Drag the status column name you want to change the order and move it on a new place 
    and drop it. To change column width, set a mouse cursor onto the right edge of the col-
    umn to change, drag the mouse on it and adjust the column width.
    Sorting the status list
    The order of the targets on the status list can be changed by clicking the column name 
    which you want to sort. It switches ascending or descending order by clicking the column 
    name each time.
    Sort by clickingDrag to move columnDrag to change column width
    Customizing the status list  
    						
    							22
    Chapter 3 Basic Operation
    Viewing the alert information
    1  Click button on the tool bar. The alert display window appears and the alert informa-
    tion of all the targets which are having an alert is listed on this window as the below.
    2  
    To export the alert information as text file (CSV file), click Export button.
    0  
    Column width can be changed with dragging the right edge of the column. The column order can be changed with drag and drop the column. Column can not be deleted.  
    						
    							23
    Viewing the event log
    1  Click button on the tool bar. The event log display window appears and the events 
    which have been happened on the targets  are listed on this window as the below.
    2  
    To export these events as text file (CSV file), click Export button.
    3  
    To delete the event log, select the accrual date item you intend to delete by clicking and 
    then click Delete button. On the confirmation dialog, click Ye s to execute deletion.
    Items Description
    Accrual date .........Accrual date of the event
    Target name .........Name of the network equipment
    IP address ...............IP address of the network equipment
    Event .........................Type of the Event (ALERT, TRAP, SYSERR ) (See table on the next page)
    Type ...........................Type of the Event (See table on the next page)
    Warning column ..........Warning column of the Event (See table on the next page)
    Warning value ....Warning value of the Event (See table on the next page)
    Unit .............................Displays unit of the warning value.
    Event log information items
    0  The listed items are fixed.
    0  The order of the event log list can be changed temporarily by clicking the column name which you want to sort. It switches ascending or descending order by clicking the column name each time.
    0   
    Column width can be changed by dragging the right edge of the column. The column order can be changed with drag and drop the column. Column cannot be deleted.
    Viewing the event log  
    						
    							24
    Chapter 3 Basic Operation
    EventTypeWarning ColumnWarning ValueDescription
    ALERTON :  Abnormality has happenedOFF :   Abnormality has been cleared
    ConnectUn-connectedConnectedAcquisition error
    *  Refer to the next page
    Power status
    PowerFailureTemperatureErrorNormal (AfterTempError)RS232CFailurePower managementShutter managementLampFailureNormal(Standby)Normal(OnStartingUp)Normal(OnCoolingDown)Normal(PowerOn)TemperatureError(OnCoolingDown)Power management(OnCoolingDown)Shutter management(OnCoolingDown)LampFailure(OnCoolingDown)
    Input statusSignalsInterruptedSignalsInputtedInside Temperature status (A to C)External Temperature statusAbnormal
    Lamp status (1 to 4)FailureReplace
    Lamp time (1 to 4)(setting time)
    Filter statusCloggedWarning
    Filter time(setting time)
    TRAP
    LampFailureLamp status (1 to 4)Failure
    LampReplaceReplace
    PowerOFFPowreFailurePowerManagementShutterManagementPower status
    Normal(Standby)Normal(OnCoolingDown)PowerFailurePower managementPower management(OnCoolingDown)ShutterManagementShutterManagement(OnCoolingDown)
    TemperatureErrorInside Temperature status (A to C)External Temperature statusAbnormal
    SignalIsInterruptedInput statusSignalIsInterrupted
    LampReplacementTimeLamp time (1-4)(lamp time)
    FilterReplacementTimeFilter time(filter time)
    CloggedFilterWarningFilter statusCloggedWarning
    AutoPlayErrorn/aError
    WarningOnConstantModeForBrightnessn/an/a
    SYSERR*Mail Transfer*MemoryErrorn/a *1n/a *1
    *1  When PJ Network Manager could not send mail or acquire the memory, no message is displayed in "Warning column" and "Warning value".
    0 For further details of each warning column and value, refer to the next page.
    Description of Event, Type, Warning column, Warning value   
    						
    							25
    0  The column order and width of the event log window are saved to the registry of the computer.
    0  Up to 1000 of events can be stored. If it exceeds 1000 events, the oldest event is deleted and the latest event is added. The event log can be saved to the management file.
    0  This Warning column is not available for some projector's model types.
    Description of warning value 
    0  The warning value with "*" in the above table shows the event when the alert has cleared, alert type is "OFF". 
    Description of Event, Type, Warning column, Warning value 
    Warning ColumnWarning ValueDescription
    ConnectUn-connectedConnected *Acquisition error
    Projector has been disconnected from the networkProjector has been connected to the networkPJ Network Manager could not acquire the MIB information from the equipment
    Power status
    Power failureProjector turned off due to the power failure of the projectorTemperatureErrorThe projector turned off due to temperature error occurredNormal (AfterTempError)Normal after temperature error occurredRS232CFailureThe RS-232C communication error occurredPower managementThe power management function turned projector lamp offShutter managementThe shutter management function turned projector lamp offLampFailureThe lamp failure occurredNormal(Standby) *Projector turned into standby normallyNormal(OnCoolingDown) *On cooling down normally due to projector turned off
    Input signal statusSignalsInterruptedSignalsInputted *The signal was interruptedThe signal was inputted again
    Inside Temperature status (A to C)External Temperature statusAbnormalThe projector turned off when the temperature was abnormally high
    Lamp statusON *FailureReplace
    When the lamp is onWhen the lamp failed to ignite.It reached lamp replacing time.Lamp time(lamp time)It reached user setting lamp replacing time
    Filter statusCloggedWarningFilter has been cloggedFilter is close to cloggingFilter time(filter time) It reached user setting filter time(Auto play error)n/aThe error occurred during the auto image display(WarningOnConstantModeForBrightness)n/aThe brightness (Current value) continuously goes down a cer-tain rate from the value in Constant mode.   
    						