June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE 2 - 75 2 593 Image Gamma data slope adjust- mentText/Photo PPC 0 SYS One’s place: 0: Equivalent to the set value 5 1 to 9: Select the slope of Gamma curve (The larger the value is, the larger the slope becomes.) Ten’s place: 0: Equivalent to the set value 5 1 to 9: Select the slope of low density (The smaller the value is, the darker the background becomes.) 00: Use default value 1 594...
Page 112
e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC 2 - 76 620 Image Sharpness adjustmentText/Photo PPC EUR: 1 UC: 1 JPN: 0 SYS When the value increases, the image becomes sharper. When the value decreases, the image becomes softer. The smaller the value is, the less the moire becomes. One’s place: Fixed value (05-620 is “1”, 05-621 is “2”, 05-622 is “5”) Ten’s place: Adjustable from 0 to 9 regarding the default value as the stan- dard...
Page 113
June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE 2 - 77 2 672-0 Image Adjustment of printer image densityNormal PRT 0 M Adjustment of the image density. With decreasing the value, the text becomes lighter. 4 672-1 PRT 4 M 4 672-2 PRT 5 M 4 672-3 PRT 6 M 4 672-4 PRT 10 M 4 676-0 Toner sav- ingPRT 0 M 4 676-1 PRT 2 M 4 676-2 PRT 3 M 4 676-3 PRT 4 M 4 676-4 PRT 5 M 4 693 Image Range correc- tion on origi- nal set on the RADFText/Photo PPC...
Page 114
e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC 2 - 78 710 Image Density adjustment Fine adjust- ment of “man- ual density”/ Center valuePhoto FAX 128 SYS When the value increases, the image at the center step becomes darker. 1 714 Text/Photo FAX 128 SYS 1 715 Image Density adjustment Fine adjust- ment of “man- ual density”/ Light step valuePhoto FAX 20 SYS When the value increases, the image of the “light” steps becomes lighter. 1 719...
Page 115
June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE 2 - 79 2 830 Image Range correc- tion on origi- nal set on the RADFText/Photo SCN 12 SYS Sets whether the value of the background peak and text peak are fixed or not. One’s place is an adjustment for “auto- matic density” and ten’s place is for “manual den- sity”. Once they are fixed, the range correc- tion is performed with standard values. The values of the back- ground peak and text peak...
Page 116
e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC 2 - 80 865-0 Image Sharpness adjustment (Text/Photo)Reproduc- tion ratio 40% or smallerSCN 1 SYS When the value increases, the image becomes sharper. When the value decreases, the image becomes softer. The smaller the value is, the less the moire becomes. Ones place: Fixed value (05-865 is “1”, 05-866 is “2”, 05-867 is “5”) Tens place: Sharpness intensity (0: Use default value, 1-9:...
Page 117
June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE 2 - 81 2 916 Image Range correc- tion on origi- nal set on the RADFCustom Mode 1 PPC EUR:12 UC:12 JPN:22 SYS Set whether the values of the background peak and text peak are fixed or not. Ones place is an adjustment for “auto- matic density” and tens place is for “manual den- sity”. Once they are fixed, the range correc- tion is performed with standard values. The values of the background...
Page 118
e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC 2 - 82 931 Image Density adjustment Fine adjust- ment of “man- ual density”/ Center valueCustom Mode 1 PPC 128 SYS When the value increases, the image of the center step becomes darker. 1 932 Custom Mode 2PPC 128 SYS 1 933 Custom Mode 3PPC 128 SYS 1 934 Image Density adjustment Fine adjust- ment of “man- ual density”/ Light step valueCustom Mode 1 PPC 20 SYS When the value increases, the...
Page 119
June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE 2 - 83 2 2.2.7 Setting mode (08) (e-STUDIO200L/230/280) Procedure 1 * Press [FUNCTION CLEAR] to enter minus (-). Procedure 2 Procedure 3 Procedure 4 * Press [FUNCTION CLEAR] to enter minus (-). Procedure 5 * Press [HELP] to enter “-”. The items in the setting code list can be set or ch anged in this setting mode (08). (Stores value in RAM) [0][8] [POWER] [POWER] OFF/ON (Exit) [Digital key](Code) [START]...
Page 120
e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC 2 - 84 Procedure 7 Procedure 9 Procedure 10 Procedure 11 and 12 *1. Press [MONITOR/PAUSE] to enter “-”, when enteri ng telephone number. *2. The data are stored in SYS-RAM in procedure 11 and stored in NIC-RAM in procedure 12. Procedure 14 [0][8] [POWER] [POWER] OFF/ON (Exit) [Digital key] (Code)[Digital key] (Setting) [CLEAR] (Corrects value) [START](HDD formatting) [CANCEL] [ENTER] or [INTERRUPT]...