e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 12 24 09 Printer counter clear 
(PRT.CLR.)[Function]
When [OK (ENTER)/START] key is pressed, the printer counter value is cleared to 0, and 000,000 is
displayed on the LCD.
[Operation]
10 FAX counter clear (FAX 
CLR.) (Executable only 
when the FAX is installed.)[Function]
When PRINT switch is pressed, the FAX count value is set to 0 and 000,000 is displayed on the
LCD.
[Operation]
13 Scanner counter clear 
(SCAN CLR.)[Function]
When [OK...

Page 82

e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 13 26 02 (R)ADF setting (ADF/RADF) 
(Executable only when the 
ADF/RADF is installed.)[Function]
When this test command is executed, the current set ADF is displayed. Enter the code number corre-
sponding to the desired ADF and press [OK (ENTER)/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
03 Second cassette setting 
(2ND TRAY)[Function]
When this test command is executed, the current set second...

Page 83

e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 14 26 30 CE mark support control ON/
OFF (CE MARK)[Function]
When this test command is executed, the current set CE mark support control is displayed. Enter the
code number corresponding to the desired CE mark support control and press [OK (ENTER)/START]
key to save the setting.
[Operation]
The operation is similar to test command 21-01.
37 Cancel of stop at developer 
life over (DVLP LIFE END)[Function]
When this test command is executed, the...

Page 84

e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 15 26 43 Side void amount setting 
(SIDE VOID)[Function]
When this test command is executed, the currently set code of the side void quantity is displayed (ini-
tial display), and the set data are saved. (Setting range: 0 – 10, Default: 4 (= One side 2.0mm)) 
∗When the adjustment value is increased by 1, the side void is changed as follows:
Side void adjustment: The side void is increased by 0.5mm. (The side void of “Set value x 0.5mm”
is...

Page 85

e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 16 41 06 OC cover float detection 
level (OC FLOAT LEVEL) 
(Disabled when set to OC) 
(Executable only when the 
ADF/RADF is installed.)[Function]
When this test command is executed, the current set value is displayed. When [OK (ENTER)/START]
key is pressed, the mirror base unit moves to the ADF scan position to acquire the OC cover float
detection level.
When the mirror base unit returns to the home position, the acquired value is displayed....

Page 86

e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 17 43 05 Fusing temperature setting 
in duplex copy (FU TEMP 
DPLX) (Enabled when 
Duplex setting is ON)[Function]
In the case of duplex copy, the shift temperature set with this test command is applied to the fusing
temperature.
When this test command is executed, the current set code number is displayed. 
Enter the desired code number and press [OK (ENTER)/START] key to save the setting.
[Operation]
The operation is similar to test command...

Page 87

e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 18 46 01 Copy density adjustment 
(300dpi) (EXP.LEVEL 300)[Function]
Copy density is set for each mode.
When this test command is executed, the current se value is displayed in 2 digits (Default: 50).
Change the set value and press [START] key to make a copy under the set value.
When the set value is increased, the copy becomes darker. When the set value is decreased, the
copy becomes lighter.
In this case, only Exp.3 copy is made. When,...

Page 88

e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 19 46 12 Density adjustment in the 
FAX mode (Collective 
adjustment) (Executable 
only when the FAX is 
installed.)[Function]
When [START] key is pressed, scan is executed with the entered exposure adjustment value and the
data stored on the FAX side is rewritten into the entered value.
All data of the exposure adjustment values are rewritten into the same value.
For the density adjustment table data, refer to TC46-13 (density adjustment...

Page 89

e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 20 46 15 FAX mode density 
adjustment (Super fine) 
(Executable only when the 
FAX is installed.)[Function]
When [START] key is pressed, scan is started with the entered exposure adjustment value and the
data of the selected mode on the FAX side is changed to the entered value.
For the density adjustment value table data, refer to TC46-13 (FAX mode density adjustment (normal
text).)
[Operation]
18 Image contrast adjustment 
(300dpi) (GAMMA...

Page 90

e-STUDIO162/162D/151/151D  TEST COMMAND, TROUBLE CODES  10 - 21 46 19 Exposure mode setting (AE 
MODE)[Function]
<
γ table setting>
When this test command is executed, the code number of the current set gamma table is displayed.
(Default: US -1/Ex US -2)
Enter the code number corresponding to the desired gamma table, and press [
←/→] key to change
the mode and write into the EEPROM.

When setting the 
γ table, press [→] key to change to the AE operation mode, and the current set code
number of the AE...