Toshiba Estudio 162 Owners Manual
Here you can view all the pages of manual Toshiba Estudio 162 Owners Manual. The Toshiba manuals for Copier are available online for free. You can easily download all the documents as PDF.
Page 41
e-STUDIO162/162D/151/151D OPERATIONAL DESCRIPTIONS 7 - 6 (2) Manual multi paper feed operation 1) Before paper feed operation, the manual paper feed solenoid (MPFS) is turned OFF as shown in the figure below. 2) When the PRINT button is pressed, the manual paper feed solenoid (MPFS) turns on to disengage the manual paper feed latch. A from the manual paper feed clutch sleeve A, rotating the manual paper feed roller and the manual take-up roller. At the same time, the manual paper feed stopper opens and...
Page 42
e-STUDIO162/162D/151/151D OPERATIONAL DESCRIPTIONS 7 - 7 (3) Conditions of occurrence of paper misfeed a. When the power is turned on: PPD or POD is ON when the power is turned on. b. Copy operation 6. D-D (Duplex to Duplex) mode paper/ document transport (Duplex model) A. Initial state Set duplex documents on the document tray. Set paper on the cassette. (In the duplex mode, the manual feed tray cannot be selected.) B. Front copy Document transport: The document feed roller feeds the document from the...
Page 43
e-STUDIO162/162D/151/151D OPERATIONAL DESCRIPTIONS 7 - 8 Switchback operation is made after back copying in order to discharge documents according to the setting. Set document Documents after discharge, There are following job modes as well as D-D mode. S - S (Simplex to Simplex) S - D (Simplex to Duplex), Rotation copy mode (The back images are rotated 180°C.) S - D (Simplex to Duplex), Copy mode without rotation D - S (Duplex to Simplex) Rotation copy mode: The front and the back are in upside down...
Page 44
e-STUDIO162/162D/151/151D DISASSEMBLY AND ASSEMBLY 8 - 1 [8] DISASSEMBLY AND ASSEMBLY The disassembly and assembly procedures are described for the fol- lowing sections: 1. High voltage section 2. Operation panel section 3. Optical section 4. Fusing section 5. Tray paper feed/transport section 6. Manual paper feed section 7. Rear frame section 8. Power section 9. Duplex motor section 10. Reverse roller section 1. High voltage section A. List B. Drum replacement 1) Remove the drum cover. (4 Lock Tabs)2)...
Page 45
e-STUDIO162/162D/151/151D DISASSEMBLY AND ASSEMBLY 8 - 2 5) Remove the cleaning blade. Note: Dispose the cleaning blade which was removed. 6) Clean the cleaning section and the waste toner pipe to remove waste toner completely with a vacuum cleaner. 7) Remove the felt and duplex tape completely. Note: Be careful not to scratch or bend the sub blade. 8) Attach the cleaning blade. Securely insert the plate section of the cleaning blade into the unit and fix it with a screw. Do not touch the cleaning blade...
Page 46
e-STUDIO162/162D/151/151D DISASSEMBLY AND ASSEMBLY 8 - 3 12) Attach the detection gear. Note: •The detection gear is not installed to the drum cartridge packed with the main body. Add a new one. 13) Attach the drum cover. Note: After attaching the drum cover, do not make a copy. When attaching the drum cover, engage the detection gear 20T rib with the 30T gear rib, and attach the drum cover to the process frame. C. Disassembly procedure (Transfer charger unit) 1) Press the side cover open/close button...
Page 47
e-STUDIO162/162D/151/151D DISASSEMBLY AND ASSEMBLY 8 - 4 2) Set the charger cleaner to the transfer unit, and move it recipro- cally a few times in the direction of the arrow shown in the figure below. F. Charger wire replacement 1) Remove the TC cover and remove the screw. 2) Remove the spring and remove the charger wire. 3) Install a new charger wire by reversing the procedures (1) and (2). At that time, be careful of the following items. •The rest of the charger wire must be within 1.5mm. Refer to...
Page 48
e-STUDIO162/162D/151/151D DISASSEMBLY AND ASSEMBLY 8 - 5 3) Remove four screws, and remove the operation cabinet. 4) Remove four screws, and remove the operation PWB. C. Assembly procedure For assembly, reverse the disassembly procedure 3. Optical section A. List B. Disassembly procedure 1) Remove four screws, and remove the rear cabinet and the rear cabinet cover.2) Remove the four screws, remove the operation unit, and discon- nect the connector. 3) Remove the right cabinet. 4) Remove the left...
Page 49
e-STUDIO162/162D/151/151D DISASSEMBLY AND ASSEMBLY 8 - 6 10) Remove the screw, and remove the rod stopper. 11) Remove the rod. Caution: Be careful not to touch the sharp edge on the circumference of the metal frame. 12) Lift the rear side of the carriage, remove the belt and the connec- tor, and remove the carriage. C. Assembly procedure CCD core 1) Pass the core through the CCD-MCU harness. 2) Insert the CCD-MCU harness into the CCD PWB connector of the carriage unit. 3) Move the core which was...
Page 50
e-STUDIO162/162D/151/151D DISASSEMBLY AND ASSEMBLY 8 - 7 4. Fusing section A. List B. Disassembly procedure 1) Remove the connectors (3 pcs.) of the rear cabinet. 2) Open the side cover, remove two screws, and remove the fusing unit. 3) Cut the binding band, remove the screw, and remove the ther- mistor.4) Remove the screw and remove the U-turn guide. Pressure roller section disassembly 5) Remove the three screws, remove the fusing cover lower on the right side, and open the heat roller section. 6)...
All Toshiba manuals