Page 51
e-STUDIO162/162D/151/151D DISASSEMBLY AND ASSEMBLY 8 - 8 7) Remove the plate spring on the right and remove the heater lamp. 8) Remove the spring and remove the separation pawls (3 pcs.). 9) Remove the E-ring and remove the reverse gate.10) Remove the pressure release levers on the right and the left sides. 11) Remove the pressure roller, the pressure bearing, and the spring. Note: Apply grease to the sections specified with an asterisk (*). Grease: “JFE552” UKOG-0235FCZZ Heat roller disassembly...
Page 52
e-STUDIO162/162D/151/151D DISASSEMBLY AND ASSEMBLY 8 - 9 6) Remove the C-ring and the fusing bearing, and remove the heat roller. 7) Remove the parts from the heat roller. Note: Apply grease to the sections specified with ∗1. Grease: “JFE552” UKOG-0235FCZZ 8) Remove two screws and remove the thermo unit. C. Assembly procedure For assembly, reverse the disassembly procedure. 5. Tray paper feed/transport section A. List B. Disassembly procedure 1) Remove the paper holding arm. Remove the arm holder from...
Page 53
e-STUDIO162/162D/151/151D DISASSEMBLY AND ASSEMBLY 8 - 10 5) Disconnect the connector from the MCU PWB. 6) Disengage the pawls (2 positions), and remove the sensor PWB. 7) Remove the screw, and open the upper paper guide. 8) Remove the roller, and remove the belt.9) Disengage the pawl, and remove the roller knob. 10) Disengage the pawl, and shift the pulley and the bearing. 11) Remove the paper exit roller, and remove the belt, the pulley, and the bearing. 12) Remove the connector and the screw, and...
Page 54
e-STUDIO162/162D/151/151D DISASSEMBLY AND ASSEMBLY 8 - 11 13) Remove the flat cable and the grounding wire. 14) Remove the four screws, and remove the FAX PWB unit. (When the GD-1190 is installed) Caution: Be careful not to touch the sharp edge on the circumference of the metal frame the interface. 15) Disconnect the connectors. 16) Remove the three screws, and remove the MCU PWB. 17) Remove two screws and remove the toner motor.18) Remove the three screws, and remove the DUP motor unit and the belt....
Page 55
e-STUDIO162/162D/151/151D DISASSEMBLY AND ASSEMBLY 8 - 12 21) Remove the parts as shown below, and remove the pressure release solenoid and the paper feed solenoid. 22) Remove each pawl, and remove the paper exit tray.23) Remove two screws and remove the fusing connector. 24) Remove five screws and the connector, and lift the intermediate frame unit to remove. 25) Remove the four screws, and remove the lower paper guide unit. [Note for installation] Fit the lower paper guide hole (a) with the shifter...
Page 56
e-STUDIO162/162D/151/151D DISASSEMBLY AND ASSEMBLY 8 - 13 26) Disengage the pawl, and remove the pulley. 27) Shift and remove the shifter unit. 28) Remove the screw, and remove the grounding plate and the gear. 29) Remove the E-ring, the gear, and the bearing, and remove the shifter roller. 30) Put the lower paper guide unit upside down, remove the two screws, and remove the shifter motor.31) Remove the four screws, and remove the LSU. Note: When assembling, turn it to the right and attach. 1)2) 3)3)...
Page 57
e-STUDIO162/162D/151/151D DISASSEMBLY AND ASSEMBLY 8 - 14 32) Remove the screw and the E-ring, and remove the PS semi-circu- lar earth plate and the PS roller unit. 33) Remove the E-ring and remove the spring clutch from the PS roller unit. 34) Remove three screws and remove the TC front paper guide. 35) Remove the screw and the connector, and remove the PPD1 sen- sor PWB.36) Remove two E-rings and remove the paper feed roller. 37) Remove three E-rings and remove the clutch unit. 38) Remove the...
Page 58
e-STUDIO162/162D/151/151D DISASSEMBLY AND ASSEMBLY 8 - 15 6. Manual paper feed section A. List B. Disassembly procedure Multi unit 1) Remove the screw and remove the multi upper cover. 2) Remove the screw and remove the side door detection unit.3) Remove three screws and remove the multi paper feed upper frame. 4) Remove two screws and remove the multi feed bracket unit from the multi paper feed upper frame. No. Part name Ref. 1 Manual transport roller 2 Cassette detection switch 3 PPD1 sensor PWB 4...
Page 59
e-STUDIO162/162D/151/151D DISASSEMBLY AND ASSEMBLY 8 - 16 5) Remove three E-rings and remove the manual paper feed roller B9. 6) Remove the pick-up roller.7) Cut the binding band and remove the multi paper feed solenoid. C. Assembly procedure For assembly, reverse the disassembly procedure. D. Pressure plate holder attachment 1) Attach the pressure plate holder so that the resin section is not covered with the seal M1-N. 2) 1) 1) 1) 3) LOCK TOK 2)1) 1) 2) 3)Multi paper feed solenoid Pressure plate...
Page 60
e-STUDIO162/162D/151/151D DISASSEMBLY AND ASSEMBLY 8 - 17 7. Rear frame section A. List B. Disassembly procedure 1) Remove the rear cabinet. 2) Remove the connector, the flat cable, and the grounding wire. 3) Remove three screws, and remove the FAX PWB. 4) Disconnect the connector. 5) Remove two screws, and remove the scanner motor. 6) Remove two screws and one harness, and remove the main motor.7) Remove two screws and one connector, and remove the exhaust fan motor. Note: Be careful of the installing...