Page 81

Select ORIG to originate a call. When this is done, dial tone should be heard and the following
shown in the display:
where STATE:02 = call initiation
Dial a directory number for a test call. The display should update to:
where STATE:03 = call proceeding SIGNAL:01 = ringback tone ON
Immediately following, the display should update to:
where STATE:04 = call delivered
Select DISC to disconnect the call; select EXIT to exit the test mode for CAXX; select another
call appearance by selecting NEXT or LAST;...

Page 82

40d Call Termination Checkout
From another telephone, call the Primary Directory Number (PDN) of the 40d console. When this is done,
the console will ring and the following will be shown in the display:
Press the ANSWER button. You will be connected to the inbound caller and the console display will be
updated to:
Press RELEASE, hang up the other phone, and proceed to 40d Call Transfer Checkout
(page 82).
If the 40d console does not respond (i.e. no common audible or display), undertake the following...

Page 83

Press the CONNECT button. When this is done, Awaiting Network Response may be seen briefly in Line
1 of the display, then the display will clear.
Proceed to 40d Network Feature Button Checkout
(page 83).
NOTE– On occasion, if the CONNECT button is pressed immediately after dialing the last digit of the
DN, an error tone may be heard. Press the CONNECT button again.
If after pressing the CONNECT button numerous times, an error beep continues to be heard, enter the
Maintenance Mode, select SETUP, select...

Page 84

If after pressing the feature button the following is shown in the display:
followed by:
The DN that was used to initiate the desired network feature has not been assigned the feature in
network translations.
Contact your telco representative to determine whether the feature has been assigned to the DN
being used.
After reconciling network translations and the 40d program, repeat the procedures in the first three
paragraphs in this section.
If after pressing the feature button the following is shown...

Page 85

Verify that the voltage being fed to the console by the power supply is 34.0 to 56.5 VDC. This
voltage can be read across pins 7 and 8 on the console-end connector of the mounting cord.
Replace the 120d console.
120d Line Initialization Diagnostics
When power is applied to a 120d ISDN console that is connected to a fully configured and active ISDN line,
the Line Diagnostic display is automatically shown. The display is continuously updated. When all ISDN
layers are fully initialized, the display clears...

Page 86

NOTE– The above information indicates benchmark points in the initialization process. Information
and sequences may vary.
If the Line Diagnostic display does not clear, undertake the following:
1. If not already accomplished, connect the 120d console to the companion 40d console using the
data link mounting cord.
2. Determine which display or station lamps continue to show.
3. Undertake the recommended troubleshooting procedures for the specific display shown.
If station lamps11, (27), 34, (47), 54are...

Page 87

Make the appropriate 120d programming changes as required. The 120d will initialize
automatically after the changes are entered.
If station lamps11, 21, 33, 47, 53persist, temporarily remove power from the 120d console for at
least 30 seconds, then reapply it.
If screen 28 is showing continuously:
Verify that there is a SPID number entered for Terminal #2.
Make the appropriate programming changes. Layer 2 should initialize as shown in screen
29.
If screen 29 is showing continuously:
Verify that the...

Page 88

If screen 32 or 33 is not shown, it will most likely be replaced by either of the following:
Enter the Maintenance Mode, select NAMES, press the DSS button used in the beginning of this
section. When this is done, the following will be shown:
 Verify that the DSS# entry is the number to be dialed.
 Make the appropriate changes as required by selecting EDIT.
 Make the appropriate NAMES programming changes as required, then repeat the steps in this
section.
120d Call Termination Checkout
From another...

Page 89

Press CONNECT. The display will clear and the call will be transferred.
40d/120 Console Inactivity Recovery Procedures
If either the 40d or any 120d console are not functioning:
1. Verify that there is backlighting in the display of the 40d console.
2. If there is no backlighting:
Verify that the console power supply is plugged into active commercial power.
Verify that the console power supply is providing 34.0 to 56.5 VDC.
Reseat and check all console connecting cables.
Replace the affected...

Page 90

System Features
Enhanced Incoming Call Identification
The caller’s name is displayed when sent from the central office or if the number is found in the console’s
internal database. Also shown are the type of call (incoming call, unanswered station call, priority call, hold
recall, etc.) and current call state.
Programmable 1000 Entry Calling Name Database
Up to 1000 names may be stored in an internal database, allowing identification of callers when number
data is sent from the central office....