Page 141
7. EXPLANATION OF PARAMETERS 7-46 Mode Page Abbre- viation Name and description Standard valueUnit Setting range Remarks 2 0 PMOD Position command pulse train form ③ 90° phase difference two-phase pulse train The minimum pulse width values shown at bit 0/1 of the digital filter are for both H and L pulses. bit6 bit5 Command pulse form 0 1 90° phase difference two-phase pulse When bit7 = 0 bit...
Page 142
7. EXPLANATION OF PARAMETERS 7-47 Mode Page Abbre- viation Name and description Standard valueUnit Setting range Remarks 2 1 Func0 Amplifier function select 0 • This parameter selects whether external signals are made effective or are forcibly turned on internally. It also selects the overtravel input logic, the encoder used (between motor encoder and fully closed encoder) and the multiplication factor of the encoder. 0000- 0000 0, 1 ( 3) ( 4)...
Page 143
7. EXPLANATION OF PARAMETERS 7-48 Mode Page Abbre- viation Name and description Standard valueUnit Setting range Remarks 2 2 Func1 Amplifier function select 1 • A desired function can be set from the digital switch. 0000- 0000 0, 1 ( ) * Bit7 is effective in the position control mode. Bit6 is effective in the position and velocity control modes. * For details of bits 2 to 0, refer to the following...
Page 144
7. EXPLANATION OF PARAMETERS 7-49 Mode Page Abbre- viation Name and description Standard valueUnit Setting range Remarks 2 2 Func1 Amplifier function select 1 • How to use different current limit approaches Bits 2 to 0 are parameters relevant to current limit. The following describes their setting and the corresponding current limit method available. Func1 Negative polarity • Inputs negative voltage to...
Page 145
7. EXPLANATION OF PARAMETERS 7-50 Mode Page Abbre- viation Name and description Standard valueUnit Setting range Remarks 2 3 Func2 Amplifier function select 2 • A desired monitor output method or regenerative resister OL time can be selected. 0010- 0000 0, 1 ( 1) ( 3) Regenerative resistor OL time select 2 4 Monitor 2 out put polarity Alarm output method 0 Positive output at...
Page 146
7. EXPLANATION OF PARAMETERS 7-51 Mode Page Abbre- viation Name and description Standard valueUnit Setting range Remarks 2 4 Func3 Amplifier function select 3 • This parameter allows you to set the CN1-35 and 36 pins to the desired terminals. It also allows you to select the input signal for switching the control mode or gain. 0000- 0001 0, 1 ( 3) Input signal select for switching control...
Page 147
7. EXPLANATION OF PARAMETERS 7-52 Mode Page Abbre- viation Name and description Standard valueUnit Setting range Remarks 2 4 Func3 Amplifier function select 3 Precautions on setting Func3. 1 It is enabled when the switching mode is selected for the control mode. 2 This signal select is enabled when the gain switching mode is selected. 3 Setting bits 3, 2, 1 and 0 at 1010 in the velocity control...
Page 148
7. EXPLANATION OF PARAMETERS 7-53 Mode Page Abbre- viation Name and description Standard valueUnit Setting range Remarks 2 5 Func4 Amplifier function select 4 • CN1-39 and 40 pins may be set for desired output terminals. 0000- 0001 0, 1 * For details of CMD: Command accept permit, refer to 6.1 Operation Sequence. The standard value is set at 00000100 in the position control mode. CN1-39 pin output...
Page 149
7. EXPLANATION OF PARAMETERS 7-54 Mode Page Abbre- viation Name and description Standard valueUnit Setting range Remarks 2 6 Func5 Amplifier function select 5 • Selects the encoder output format or the command input polarity. 0000- 0000 0, 1 ( 2) ( 3) 1 Even if you choose the fully closed encoder using the Func0 bit7 parameter, divided output remains the same. Fully closed encoder can be...
Page 150
7. EXPLANATION OF PARAMETERS 7-55 Mode Page Abbre- viation Name and description Standard valueUnit Setting range Remarks 2 7 Func6 Amplifier function select 6 • This parameter is used for changing the contents of parameters or permitting execution of the test mode. 0000- 0000 0, 1 Note: Set bit2 to “0”. * After operation, bits 7 and 6 must be set at 0 again. Turning off the control power also returns bits 7, 6 and 4 to 0. * If...