Page 181
8. MAINTENANCE 8 - 25 8.4 Maintenance The Servomotor and amplifier do not require any special inspection. To ensure optimum performance over their lifetimes, however, the user is expected to implement a reasonable level of inspection and maintenance, paying attention to the following points . [Inspection Procedure ] Table 8-3 Inspection Procedure Check Check conditions Check item Check method Corrective point Timing In-operatio n Out-of-ope ration measure Servomotor...
Page 182
8. MAINTENANCE 8-26 8.5 Overhaul Parts The parts listed in Table 8.4 will deteriorate with age. For maintenance, inspect periodically. Table 8-4 Periodical Parts Inspection No. Parts Average replacement interval Method of replacement and others 1 Capacitors for main circuit smoothing 5 years Replace with new one. Load rate: 50% maximum of the amplifier’s rated output current. Working condition: Year-round average temp. 106°F (40°C) 2 Cooling fan motor 5 years Replace...
Page 183
9. SPECIFICATIONS 9-1 SPECIFICATIONS 9.1 Servo Amplifier............................................................................. 9-3 9.1.1 Common Specifications..................................................... 9-3 9.1.2 Acceleration and Decelerate Time .................................... 9-5 9.1.3 Allowable Repetition Frequency ........................................ 9-6 9.1.4 Precautions on Load......................................................... 9-9...
Page 184
9. SPECIFICATIONS 9-2 9.3 Combination Specifications ........................................................ 9-111 9.3.1 P1 Series (B Coil) + PY2 ...................................................9-111 9.3.2 P1 Series (H Coil) + PY2...................................................9-111 9.3.3 P2 Series (H Coil) + PY2...................................................9-111 9.3.4 P2 Series (D Coil) + PY2...................................................9-112 9.3.5 P3 Series (D Coil) +...
Page 185
9. SPECIFICATIONS 9-3 9.1 Servo Amplifier 9.1.1 Common Specifications Table 9-1 Common Specifications Model No. PY2A015 PY2A030 PY2A050 PY2E015 PY2E030 Control function Velocity, torque or position control (through switching of parameters). Control method IGBT PWM control, sine wave drive. Main circuit • 3-phase, 200 VAC to 230 VAC +10%, ‐15%, 50/60 Hz±3Hz. • Single-phase, 200 VAC to 230 VAC +10%, ‐15%, 50/60 Hz±3Hz. • Single-phase, 100 VAC to 115 VAC +10%,‐15%, 50/60...
Page 186
9. SPECIFICATIONS 9-4 *1: The supply voltage shall be within the specified range. 200 VAC power supply input type (PY2A) Specified voltage range: 170 to 253 VAC The supply voltage must not exceed 230 VAC+10% (253 V). 100 VAC power supply input type (PY2E) Specified voltage range: 85 to 127 VAC The supply voltage must not exceed 115 VAC+10% (127 V). If the voltage exceeds the specified range, install a step-down transformer. *2: When the amplifier is housed in a box, the...
Page 187
9. SPECIFICATIONS 9-5 9.1.2 Acceleration and Deceleration Time The acceleration time (t a) and deceleration time (t b) under certain load conditions are calculated using the following expressions. The expressions, however, are for within the rated speed, ignoring the viscosity torque and friction torque of the motor. Acceleration time : t a = (J M + J L) • • (sec) Deceleration time : t b = (J M + J L) • • (sec) t a : Acceleration time (sec) t b...
Page 188
9. SPECIFICATIONS 9-6 9.1.3 Allowable Repetition Frequency Start and stop repetition is limited by both the Servomotor and Servo Amplifier. Consideration is required to satisfy the requirements of both at the same time. ● Allowable repetition frequency based on the Servo Amplifier For use with a high frequency of starting and stopping, check that it is within the allowable frequency beforehand. The allowable repetition frequency varies with each combined motor type, capacity, load...
Page 189
9. SPECIFICATIONS 9-7 (1) When the motor repeats a constant-speed status and a stop status When the operating state is as in Fig. 9-2, use the motor at a frequency in which the effective motor armature current effective value is at the motor rated armature current (I R) or lower. Supposing the operating cycle is t, the usable range is represented in the following expression. t ≧ [s] When the cycle time (t) has already been determined, find I P, ta and tb...
Page 190
9. SPECIFICATIONS 9-8 (2) When the motor repeats acceleration, deceleration and stop statuses This operating status is shown in Fig. 9-3, and the allowable value n (time/min) of repetition frequency can be obtained by the following expression. n = 2.86 × 10 2 × × × TR2 (times/min) T R: Rated torque Fig. 9-3 Motor Current and Speed Timing Chart (3) When the motor repeats acceleration, constant-speed and deceleration...