8. MAINTENANCE 8 - 15 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 AbbreviationAlarm Name Alarm Clear Contents 1111 DSPE Servo processor error Not possibleBuilt-in servo processor (DSP) of amplifier is malfunctioning. Alarm code 0,1 indicates: when Func2/ bit7,6 =”0,0”, “0”= output open and “1”= output short. Operating state when alarm occurred POSSIBLE CAUSES Alarm history OPERATING STATE 1 2 When control power supply is turned on △ ○ DSPE During operation ○...
Page 172
8. MAINTENANCE 8 - 16 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 Abbreviation Alarm NameAlarm Clear Contents 0101 RGOH Overheat of built-in regenerative resistor Possible Overheating detected in internal regenerative resistor module. Alarm code 0,1 indicates: when Func2/ bit7,6 =”0,0”, “0”= output open and “1”= output short. Operating state when alarm occurred POSSIBLE CAUSES OPERATING STATE 1 2 3 4 When control power supply is turned on △ ○ ○ During operation △ ○ ○...
Page 173
8. MAINTENANCE 8 - 17 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 Abbreviation Alarm NameAlarm Clear Contents 0101 RGOL Regenerative error Possible Overload detected in regenerative resistor Alarm code 0,1 indicates: when Func2/ bit7,6 =”0,0”, “0”= output open and “1”= output short. Operating state when alarm occurred POSSIBLE CAUSES OPERATING STATE 1 2 3 4 5 6 7 8 When control power supply is turned on ○ When main circuit power supply is turned on...
Page 174
8. MAINTENANCE 8 - 18 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 AbbreviationAlarm NameAlarm Clear Contents 1111 MEME Memory error Not Possible• Amplifier capacity does not match motor code • Motor code change alarm • Error detected in the built-in non-volatile memory of amplifier Alarm code 0,1 indicates: when Func2/ bit7,6 =”0,0”, “0”= output open and “1”= output short. Operating state when alarm occurred POSSIBLE CAUSES OPERATING STATE 1 2 3 When control power...
Page 175
8. MAINTENANCE 8 - 19 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 AbbreviationAlarm NameAlarm Clear Contents 1000 AEE Absolute sensor battery failure Possible Multiple-rotation data is indefinite due to battery back-up failure of absolute sensor. Alarm code 0,1 indicates: when Func2/ bit7,6 =”0,0”, “0”= output open and “1”= output short. Operating state when alarm occurred POSSIBLE CAUSES OPERATING STATE 1 2 3 4 When control power supply is turned ON ○ ○ ○ △ During...
Page 176
8. MAINTENANCE 8 - 20 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 AbbreviationAlarm NameAlarm Clear Contents (Comes off) 1111 CPUE Amplifier error Not PossibleBuilt-in CPU of amplifier is malfunctioning Alarm code 0,1 indicates: when Func2/ bit7,6 =”0,0”, “0”= output open and “1”= output short. Operating state when alarm occurred POSSIBLE CAUSES OPERATING STATE 1 2 3 4 When control power supply is turned on △ ○ ○ During operation △ ○ ○ Corrective Measures CAUSE...
Page 177
8. MAINTENANCE 8 - 21 8.2 Troubleshooting (Non-Alarm) The following are the causes and corrective measures for troubleshooting non-alarm malfunctions. Consult your Sanyo Denki dealer should the malfunctions persist even after performing these troubleshooting measures. Please take note that it is dangerous to perform some of these procedures without first switching off the main power supply. Table 8-2 (1/2) Troubleshooting (Non-Alarm) No Malfunction Inspection Causes and corrective...
Page 178
8. MAINTENANCE 8 - 22 Table 8-2 (2/2) Troubleshooting (Non-Alarm) No Malfunction Inspection Causes and corrective measures 6 Excessive overshoot/undershoot during start/stop • Servo tuning at “High” • Lower velocity loop gain • Increase integral time constant • Loosen acceleration / deceleration command pattern • Use position command low pass filter (1) Check for mechanical faults • Operate servomotor by itself • Check centering and balance on coupling 7 Abnormal noise (2)...
Page 179
8. MAINTENANCE 8 - 23 Alarm history will be displayed with switch after switching slider on front panel to “HISTORY”. Table 8-2-2 Alarm History Display Switch No. Status 0 Display current alarm and status (Normal setting) 1 Display the last alarm 2 Display the second alarm to the last 3 Display the third alarm to the last 4 Display the fourth alarm to the last 5 Display the fifth alarm to the last 6 Display the sixth alarm to the last 7 Display the seventh alarm...
Page 180
8. MAINTENANCE 8 - 24 8.3 Switching of Velocity Loop Proportional Gain Using Rotary Switch 8.3.1 Overview The PY or PY2 amplifier allows for easy switching of the velocity loop gain with its 8-position rotary switch located on the front of the amplifier. 8.3.2 Setting Procedure Set the slide switch on the front of the amplifier to GAIN. Then, set the following parameters. Operator Mode0-12 Velocity loop proportional gain add value (KvpA) This parameter sets a weight per rotary...