Sanyo Denki Py 2 Manual
Here you can view all the pages of manual Sanyo Denki Py 2 Manual. The Sanyo manuals for Amplifier are available online for free. You can easily download all the documents as PDF.
Page 151
7. EXPLANATION OF PARAMETERS 7-56 Mode Page Abbre- viation Name and description Standard valueUnit Setting range Remarks 3 0 Kp Position loop gain • Proportional gain of the position controller. 45 (30) rad/S 1 to 1000 ( 1) 1 Kvp Velocity loop proportional gain • Proportional gain of the velocity controller (proportional integral controller). Setting unit represents the value when the load inertia is 0. 100 (70) Hz 10 to 3000 ( 2) 2 Tvi Velocity loop integral time...
Page 152
7. EXPLANATION OF PARAMETERS 7-57 Mode Page Abbre- viation Name and description Standard value Setting range Remarks 4 0 M1 Monitor output select 1 • The contents of monitor 1 output (CN1-15 pin) can be selected among the following 19 types. Vm0.5 mV/min-1 19 types Where, IR : Rated armature current. Full : Allowable power of built-in regenerative resistor. 1 M2 Monitor output select 2 • The monitor 2 output (CN1-16 pin) can be...
Page 153
7. EXPLANATION OF PARAMETERS 7-58 Mode Page Abbre- viation Name and description Standard value Setting range Remarks 4 2 Func Servo function select • Selectable enabled/ disabled of gain switch and real time automatic tuning functions. Normal 4 choices 3 TYPE Control mode • You can choose a desired control mode from position, velocity and torque control. For the switch type, you can specify a desired control mode from CN1-36 pin or 35 pin....
Page 154
7. EXPLANATION OF PARAMETERS 7-59 Mode Page Abbre- viation Name and description Standard value Setting range Remarks 4 4 ENKD Encoder type • Selects the type of encoder used. $$$$ 4 types $$$$ : The standard value varies according to the specifications employed at the time of shipment. 5 ABSF ABS sensor format • A desired format can be selected from the following. 2048FMT 4096FMT 8192FMT 16384FMT 32768FMT 65536FMT 131072FMT 262144FMT...
Page 155
7. EXPLANATION OF PARAMETERS 7-60 Mode Page Abbre- viation Name and description Standard value Setting range Remarks 4 8 PSKD Power supply type • Selects the type of power supply for the servo amplifier’s main power supply circuit. • Selectable power supplies differ depending on the amplifier series. PY2A series (200 VAC input type) 200 VAC, 3ph (200 VAC, 3-phase) ↓ ↑ 200 VAC, 1ph (200 VAC, single-phase) PY2E series (100 VAC input type) Only 100 VAC, 1ph (100...
Page 156
7. EXPLANATION OF PARAMETERS 7-61 Mode Page Abbre- viation Name and description Standard value Setting range Remark s Mode 8 0 Kp2 Position loop gain 2 • Proportional gain of the position controller. • Enabled during gain switching. 45 (30) rad/S 1 to 1000 Position control 1 Kvp2 Velocity loop proportional gain 2 • Proportional gain of the velocity controller (proportional integral controller). Setting unit represents the value when the load inertial is 0. • Enabled during...
Page 157
8. MAINTENANCE 8-1 MAINTENANCE 8.1 Troubleshooting (Alarm).............................................................. 8-2 8.2 Troubleshooting (Non-Alarm)....................................................... 8-21 8.3 Switching of Velocity Loop Proportional Gain Using Rotary Switch ............................................................ 8-23 8.3.1 Overview .........................................................................8-23 8.3.2 Setting...
Page 158
8. MAINTENANCE 8 - 2 8.1 Troubleshooting In the following pages, explanations will be provided on the possible causes of each alarm and malfunction, and of the investigative methods and corrective measures. To avoid injury, please ensure that the cause is rectified and safety is ensured before attempting to resume operation in the event of an alarm or malfunction. When an alarm occurs, the 7-segment LED status display at the front panel of the servo...
Page 159
8. MAINTENANCE 8 - 3 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 AbbreviationAlarm NameAlarm Clear Contents OC (MOC)Power element error (Over current)Possible• Error detected in internal power module (IPM) of Amplifier • Abnormal value detected in current detection module of Amplifier. 0001 IFBE Current detector error Possible• Current detector error of Servo Amplifier was detected. Alarm code 0,1 indicates: when Func2/ bit7,6 =”0,0”, “0”= output open and “1”= output...
Page 160
8. MAINTENANCE 8 - 4 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 AbbreviationAlarm NameAlarm Clear Contents 0010 OL Overload Possible• Overload was detected in servo amplifier and motor combination Alarm code 0,1 indicates: when Func2/ bit7,6 =”0,0”, “0”= output open and “1”= output short. Operating state when alarm occurred POSSIBLE CAUSES OPERATING STATE 123456 7 8 9 When control power supply is turned on ○ When servo ON is inputted ○○ ○ After position...
All Sanyo manuals