Sanyo Denki Py 2 Manual
Here you can view all the pages of manual Sanyo Denki Py 2 Manual. The Sanyo manuals for Amplifier are available online for free. You can easily download all the documents as PDF.
Page 161
8. MAINTENANCE 8 - 5 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 AbbreviationAlarm NameAlarm Clear Contents 0011 AOH Amplifier OverheatPossible• Overheat was detected in Amplifier. • Overheat was detected in regenerative resistor of Amplifier. Alarm code 0,1 indicates: when Func2/ bit7,6 =”0,0”, “0”= output open and “1”= output short. Operating state when alarm occurred POSSIBLE CAUSES OPERATING STATE 1 2 3 4 5 When control power supply is turned on △ ○ △ During...
Page 162
8. MAINTENANCE 8 - 6 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 AbbreviationAlarm NameAlarm Clear Contents 0101 OV Over voltage Possible DC voltage of main circuit of amplifier exceeded allowable voltage Alarm code 0,1 indicates: when Func2/ bit7,6 =”0,0”, “0”= output open and “1”= output short. Operating state when alarm occurred POSSIBLE CAUSES OPERATING STATE 1 2 3 4 5 6 When control power supply is turned on ○ When main circuit power supply is turned on ○ ○...
Page 163
8. MAINTENANCE 8 - 7 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 AbbreviationAlarm NameAlarm Clear Contents 0110 OS Over speed Possible Rotating speed of servomotor exceeded allowable speed (1.2 times maximum rotating speed) during operation. Alarm code 0,1 indicates: when Func2/ bit7,6 =”0,0”, “0”= output open and “1”= output short. Operating state when alarm occurred POSSIBLE CAUSES OPERATING STATE 1 2 3 4 5 When control power supply is turned on ○ △ Upon command...
Page 164
8. MAINTENANCE 8 - 8 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 AbbreviationAlarm NameAlarm Clear Contents 0111 PE Control power supply error Possible Control power supply input voltage is below specified range Alarm code 0,1 indicates: when Func2/ bit7,6 =”0,0”, “0”= output open and “1”= output short. Operating state when alarm occurred POSSIBLE CAUSES OPERATING STATE 1 2 3 When control power supply is turned on △ ○ During operation △ ○ Corrective Measures...
Page 165
8. MAINTENANCE 8 - 9 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 Abbreviation Alarm NameAlarm Clear Contents DE1 Encoder disconnection (sensor error)Not possibleDisconnection of sensor signal (A, B, C or PS signal) line was detected DE2 Serial disconnection (sensor error)Not possibleDisconnection of sensor signal (PS signal) line was detected DE3 Encoder initial error (sensor error) Not possibleInitial data of motor sensor can not be read in. 1000 DE4 Serial receiving...
Page 166
8. MAINTENANCE 8 - 10 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 AbbreviationAlarm NameAlarm Clear Contents 1001 MPE Main power supply drop Possible Main circuit power supply voltage drop Alarm code 0,1 indicates: when Func2/ bit7,6 =”0,0”, “0”= output open and “1”= output short. Operating state when alarm occurred POSSIBLE CAUSES OPERATING STATE 1 2 3 4 5 When control power supply is turned on ○ △ After main circuit power supply is turned on ○ ○ During...
Page 167
8. MAINTENANCE 8 - 11 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 AbbreviationAlarm NameAlarm Clear Contents 1010 FP Main power supply phase loss Possible Phase loss detected in 3-phase main power supply input Alarm code 0,1 indicates: when Func2/ bit7,6 =”0,0”, “0”= output open and “1”= output short. Operating state when alarm occurred POSSIBLE CAUSES OPERATING STATE 1 2 3 When control power supply is turned on ○ When main power supply is turned on ○ ○ During...
Page 168
8. MAINTENANCE 8 - 12 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 AbbreviationAlarm NameAlarm Clear Contents 1100 SE Velocity control error Possible Velocity control is not functioning normally Alarm code 0,1 indicates: when Func2/ bit7,6 =”0,0”, “0”= output open and “1”= output short. Operating state when alarm occurred POSSIBLE CAUSES OPERATING STATE 1 2 3 4 5 When control power supply is turned on ○ Upon servo ON input ○ ○ Upon command input ○ ○ ○...
Page 169
8. MAINTENANCE 8 - 13 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 AbbreviationAlarm NameAlarm Clear Contents 1101 OVF Excess position deviationPossible Position loop deviation counter exceeded allowable value Operating State when alarm occurred POSSIBLE CAUSES OPERATING STATE 12345678 9 10 111213 When control power supply is turned on ○ During stoppage at servo ON ○ ○ When command input is started ○△○○○ ○△ ○ △ During high speed...
Page 170
8. MAINTENANCE 8 - 14 Alarm Status Segment LED Display Alarm Code ALM8,4,2,1 AbbreviationAlarm NameAlarm Clear Contents 0011 EXOH External overheat Possible External overheat was detected. Alarm code 0,1 indicates: when Func2/ bit7,6 =”0,0”, “0”= output open and “1”= output short. Operating state when alarm occurred POSSIBLE CAUSES OPERATING STATE 1 2 3 4 When control power supply is turned on ○ ○ △ After operating for a short period ○ △ Corrective Measures CAUSE...