Home > Samsung > Television > Samsung Television SyncMaster 400PXn User Manual

Samsung Television SyncMaster 400PXn User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Samsung Television SyncMaster 400PXn User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1705 Samsung manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 
     
     
     
     
     
     
     
     My Computer
     URL
     NFS
     FTP
     Socket
     Serial
     
     
      
      1. My Computer  
     
      
     
     
     
     
     
     
    zYou can register files in My Computer. 
      
      2. URL   : Supportable for SyncMaster 320PXn/400P(T)Xn/460PXn only 
     
      
      
    						
    							 
     
     
     
     
     URLYou can register URLs through the Internet.
     Nick Name
    You can name a nick name of a URL to be registered so that it can 
    be used for load and edit operation. (If you register with the same 
    nick name, the existing URL, which has been registered with the 
    nick name is replaced with the new one.)
     Address
    Set a URL address to be registered.
     Connect
    Connect to a URL using the registered nick name and URL Address. 
    If the connection is successfully established, Internal Explorer is 
    launched and ( ) Add button is activated.
     AddIf the connection is successfully established, save the connection 
    information into the DB.
     Display interval
    Refresh the screen with the specified URL at each Display interval.
      
      3. NFS   : Supportable for SyncMaster 320PXn/400P(T)Xn/460PXn only 
     
      
     
     
     
     
     
     NFSYou can register TEXT(.txt) data through NFS.
     Nick Name
    You can name the nick name of a custom data to be registered so 
    that it can be used for load and edit operation. (If you register with 
    the same nick name, the existing data, which has been registered 
    with the nick name, is replaced with the new one.)
     Address 
    						
    							 Set an address to be registered. 
    (You have to set the shared IP and folder name.)
     Connect
    Connect to NFS using the registered nick name and address. If the 
    connection is successfully established, the following ( ,  ) Open 
    and Add buttons are activated.
     PathShows a successfully connected NFS path.
     Open
    File Navigation window appears where you can select a file (TEXT
    (.txt) data) using the successfully established connection 
    information.
     Add
    Load TEXT(.txt) data of the path set in the File Navigation, copy 
    the data to the server PC and save the data onto the DB. 
    =>In an original text (.txt) data file, , and LineFeed are used 
    as delimeters between cells that are determined during the Multi 
    Screen edit operation.
     Registered files
    A window that shows DB information.
     Edit
    A window appears where you can set Raw data 
    Interval/Interval/Display interval for TEXT(.txt) data. 
    If you select multiple TEXT(.txt) data, only the first data of the list 
    is modified.  
    => Raw data Interval : Time to load original TEXT(.txt) data file 
    into the buffer.  
    Interval : The time to create a file with the data loaded in the 
    buffer by separating the data into the number of columns and rows 
    set during the Multi Screen edit operation. 
    Display interval : The time to refresh the monitor screen.
     Delete
    Delete a selected TEXT(.txt) data among the registered TEXT(.txt) 
    data.  
    (Multiple selection by Shift or Ctrl key is supported for deletion)
      
      4. FTP   : Supportable for SyncMaster 320PXn/400P(T)Xn/460PXn only 
     
      
     
     
     
     
     
     FTPYou can register TEXT(.txt) data through FTP.
     Nick Name
    You can name the nick name of a TEXT(.txt) data to be registered 
    so that it can be used for load and edit operation. (If you register 
    with the same nick name, the existing data, which has been 
    registered with the nick name, is replaced with the new one.)
     Address
    Set an address to be registered.
     Connect
    Connect to FTP using the registered nick name and address. A pop-
    up window appears where you can enter the ID and password for 
    the FTP. If the connection is successfully established, the following 
    ( , ) Open and Add buttons are activated. ( ) Path : Shows the 
    path of the succefully connected FTP.
     PathShows the path of the succefully connected FTP.
     Open
    File Navigation window appears where you can select a file (TEXT 
    						
    							 (.txt) data) using the successfully established connection 
    information.
     Add
    Load TEXT(.txt) data of the path set in the File Navigation, copy 
    the data to the server PC and save the data onto the DB. 
    =>In an original text (.txt) data file, , and LineFeed are used 
    as delimeters between cells that are determined during the Multi 
    Screen edit operation.
     Registered files
    A window that shows DB information.
      
      5. Socket  : Supportable for SyncMaster 320PXn/400P(T)Xn/460PXn only 
     
      
     
     
      
     
     SocketYou can register TEXT(.txt) data through Socket.
     Nick Name
    You can name the nick name of a TEXT(.txt) data to be registered 
    so that it can be used for load and edit operation. (If you register 
    with the same nick name, the existing data, which has been 
    registered with the nick name, is replaced with the new one.)
     Address
    Set an IP address to be registered.
     Port
    Set a Port to be registered.
     Connect
    Establish Socket connection using the registered nick name and 
    address. If the connection is successfully established, the ( ) Add 
    button on the side is activated.
     AddCopy TEXT(.txt) data that is transmitted through socket to the 
    server PC and save the data onto the DB. 
    =>Data is transferred through the Socket as packets separated by 
    the length prefixed scheme. 
     
    ex) CX12abcdefghabcd 
     
    =>In an original text (.txt) data file, , and LineFeed are used 
    as delimeters between cells that are determined during the Multi 
    Screen edit operation.
    NameSize in 
    bytesDefault 
    ValueComment
    Protocol1C
    Op 
    code1X
    Size16
    The size of message in bytes not 
    including the header and size 
    fields. 
    It is written in ASCII character 
    code.
    DataVaries 
    						
    							  Registered files
    A window that shows DB information.
      
      6. Serial   : Supportable for SyncMaster 320PXn/400P(T)Xn/460PXn only 
     
      
     
     
     
     
     
     
     SerialYou can register TEXT(.txt) data through Serial.
     Nick Name
    You can name the nick name of a TEXT(.txt) data to be registered 
    so that it can be used for load and edit operation. (If you register 
    with the same nick name, the existing data, which has been 
    registered with the nick name, is replaced with the new one.)
     Add
    You can open a connection via serial cable using the connection 
    information given below and save data to a database. 
    =>Data is transferred via the Serial as packets separated by EOF. 
        ex) 12345EOFcjojzpoEOF  
    =>In an original text (.txt) data file, , and LineFeed are used 
    as delimeters between cells that are determined during the Multi 
    Screen edit operation. 
     Port
    Set a Port to be registered.
     Registered files
    A window that shows DB information.
     
     
     
     Registering to the Library Registering / the Schedule Export/Import Schedule
      
      Registering / the Schedule  
     
      
     
    The server programs Power-On option works only if the monitors power is completely 
    shut off. Please make sure not to use the Power-On option when the monitor is in the 
    process of shutting up since it can possibly cause systemetic error on the monitor.   
    						
    							 
     
     
     
     
     
     
     
     
     
     Registering / the Schedule
    Allows you to register the files to be run on the monitor in advance.
     
     
      
      1. Library  
     
      
     
     
     
     
    Registering the schedule through the library 
    Among the files on the server PC, files that are added through the registration procedures in the 
    library can be registered with the schedule.  
     
    1. When selecting a file from among the files already registered, or selecting a random file 
    from the schedule registration window, the file is selected as a schedule file through the 
    library registration procedures.  
    2. When selecting an image file for the schedule file, you can add background music from 
    among the following music files. If a schedule file is not an image file, the add/delete 
    button for the background music is not activated.   
    						
    							 
     1.Monitor List  
    Selecting either all monitors or a specific monitor, where the schedule will be added to, is 
    available from among the monitors connected via the network.  
     
    2.Schedule a File Add/Delete  
    You can select, add or delete the file to be added to the schedule.  
     
    3.Background Music Add/Delete 
    Available only when using image files.  
    Selects an audio file to use as the background music in advance when playing an image file 
    registered to the schedule.  
     
    4.Schedule  
    {Start Time  
    This means the starting time of a schedule, which can be entered in 
    years/months/days/hours/minutes.  
    It is possible to set the start time of a schedule within 7 days of the current day, however 
    setting a time later than 7 days from now is not available.  
     
    {Total Run Time  
    The total period of time reserved in the schedule.  
     
    {Option  
     
    „In repeating the schedule at an interval of a Daily/Weekly/Monthly, select the 
    interval to be repeated and the date for completing the repeat.  
    The end date of such a repetition can be set within 1 year of the current date.  
     
    „If you do not select the repeat option or do not select the end date of the 
    repetition, the schedule will be added once by default.  
     
    5.Options  
    {Insert between Existing Schedules  
    This means that a new schedule will be inserted without affecting the total playing time 
    of the existing schedules. If a new schedule to be inserted, intrudes on the end time of 
    an existing schedule, the start time selected by the user is ignored, and the start time is 
    changed to after the end time of the existing schedule. When the new schedule to be 
    added intrudes on the start time of an existing schedule, the start time of the existing 
    schedule is changed to after the end time of the new schedule.  
     
    {Ignore/Overwrite Existing Schedules  
    Existing schedules are ignored, and a new user schedule overwrites at the required time. 
    If the new schedule overlaps with an existing schedule, the time of the existing schedule 
    can be changed or even be deleted, since it is overwritten by the new schedule.  
     
    6.AV Option : Supportable for SyncMaster 320PXn/400P(T)Xn/460PXn only  
    Allows you to configure the video and sound settings while scheduling content. 
     
    {You can configure MagicBright, contrast, and brightness.  
     
      
     
    {You can configure the settings of Color Tone, Red, Green, and Blue.  
      
    						
    							  
     
    {You can configure the settings of Bass, Treble, Balance, and SRS TSXT.  
     
      
     
     
    7.Slide Show : Supportable for SyncMaster 320PXn/400P(T)Xn/460PXn only 
    Determines the slide transition interval for Slide Show.  
     
      
      2. Storage (Local/USB)  
       
     
     
     
     
     
    Registering the Storage (Local/USB) File Schedule 
    You can select a file from among the local storage of the monitor, or from the USB connected to 
    the monitor to register the selected file with the schedule.  
     
    1. From the monitor list, select a monitor where the schedule is to be registered. The 
    add/delete button of the schedule file is only activated when selecting a monitor that is 
    currently connected to the server.   
    						
    							 
    2. You can add a file from the local storage device of the monitor, or from the USB 
    connected to the monitor by pressing the add button. In this case, it will not go through 
    the library registration procedures on the server.  
    3. When selecting an image file for the schedule file, you can add background music. When 
    a schedule file is not an image file, the add/delete button for the background music is not 
    activated.  
      
      3. Input/Power  
     
      
     
     
     
     
     
     
    Registering the Input/Power Schedule  
    : Supportable for SyncMaster 400TXn only when the Source is TV. 
    You can register the input source or Power Off for the monitor with the schedule. 
     
    1. You can schedule a change of the output source or the power for the monitor.  
    2. After selecting a monitor where the schedule is to be registered in the monitor list, select 
    an input source or Power Off from the Input/Power Selection.  
    3. Set the schedule time and press the confirm button.  
    It will change into the registered output source at the start of the schedule, and it will 
    correctly return to the MagicNet Menu screen when the schedule is over.  
      
      4. Multi Screen   : Supportable for SyncMaster 320PXn/400P(T)Xn/460PXn only 
     
      
      
    						
    							 
      
     
     
    You can divide the monitor screen to display multiple contents at the same time.
     Screen Partition
    A pop-up window appears where you can select the number of 
    screens to be divided for display. (1x1, 2x1, 1x2 and 2x2 are 
    available) 
     Monitor List
    A pop-up window appears where you can select a monitor to be 
    scheduled. You can change the order of selected monitor or 
    remove a monitor.
     Selected File 
    A pop-up window appears where you can select contents to be 
    displayed on the divided screen. You can select one from 
    Movie,Music,Image,URL,NFS,FTP,Socket,Serial and Source. To 
    register contents to a divided screen, register one and press the 
     
    ◀ ▶ buttons to select another screen or select a blank 
    screen from the side Preview screen and register contents. If 
    you double-click a content from the list, the content is displayed 
    on the Preview window. You cannnot select both Movie and 
    Music at the same time even for different dividied screens. BGM 
    option is actiavted only when the selected contents are all 
    Image and URL/NFS/FTP/Socket/Serial.
     BackGround MusicA pop-up window appears where you can select a BGM to be 
    played.
     Schedule
    Set a time for schedule.
     Preview
    A window where you can preview scheduled screens to be 
    displayed.
     TEXT(.txt) data
    You can set the formats of TEXT(.txt) data for display. 
    (Font/Size/Width/Italic/Underline/Align Left/Center/Align 
    Right/Sort/Color/Background Color/Boundary Color)
     File save
    You can save the current schedule and load a saved schedule.
     Slide Show
    Determines the slide transition interval for Slide Show.
      
      4. Multi Screen - Edit Data   : Supportable for SyncMaster 320PXn/400P(T)Xn/460PXn only 
     
      
      
    						
    All Samsung manuals Comments (0)