713 Using MDC 3 Using MDC MDC (Multiple Display Control) is an application that allows you to easily control multiple display devices simultaneously using a PC. 3.1 Configuring Settings for Multi Control MENU [] System Multi Control ENTER [ ] Assign an individual ID to your product. 3.1.1 Configuring settings for Multi Control zMDC Connection Select a method to connect to MDC to receive the MDC signal. †RS232C MDC Communicate with MDC via the RS232C-stereo cable. †RJ45 MDC Communicate with MDC via the RJ45 cable. zID Setup Assign an ID to a set. (Range: 0~99) Press or to select a number, and press [ ]. zID Input Enter the ID number of the product connected to the input cable for input signal reception. Enter the number you want using the number buttons on the remote control. m
72 Using MDC 3 3 Using MDC 3.2 MDC Program Installation/Uninstallation 3.2.1 Installation 1Insert the installation CD into the CD-ROM drive. 2Click the MDC Unified installation program. If a software installation window is not di splayed on the main screen, install with the MDC Unified execution file in the MDC folder on the CD. 3Click "Next" in the displayed Installation Wizard screen. 4In the "License Agreement" window displayed, select "I accept the terms in the license agreement" and click "Next". 5In the displayed "Customer Informa tion" window, fill out all the information fields and click "Next". 6In the displayed "Destination Folder" window, select the directory path you want to install the program in and click "Next". If the directory path is not specified, the program will be installed in the default directory path. 7In the displayed "Ready to Install the Program" window, check the directory path to install the program in and click "Install". 8Installation progress will be displayed. 9Click "Finish" in the displayed "InstallShield Wizard Complete" window. Select "Launch MDC Unified" and click "Fin ish" to run the MDC program immediately. 10The MDC Unified shortcut icon will be created on the desktop after installation. zThe MDC execution icon may not be displayed depending on the PC system or product specifications. zPress F5 if the execution icon is not displayed. 3.2.2 Uninstallation 1Select Settings > Control Panel on the Start menu and double-click Add/Delete Program. 2Select MDC Unified from the list and click Change/Remove. MDC installation can be affected by the graphics card, mother board and network conditions.
73 Using MDC 3 3 Using MDC 3.3 What is MDC? Multiple display control "MDC" is an application that allows you to easily control mu ltiple display devices simultaneously using a PC. 3.3.1 Connecting to MDC Using MDC via RS-232C (serial data communications standards) An RS-232C serial cable must be connected to the serial ports on the PC and monitor. RS232C IN / OUT
74 Using MDC 3 3 Using MDC Using MDC via Ethernet Enter the IP for the primary display device and connect the device to the PC. One display device can connect to another using an RS-232C serial cable. Connection using a direct LAN cable Multiple products can be connected using the [RJ45] port on the product and the LAN ports on the HUB. Connection using a cross LAN cable Multiple products can be connected using the [RS232C IN / OUT] port on the product. RJ45 RS232C OUT RJ45
75 Using MDC 3 3 Using MDC 3.3.2 Connection Management Connection management includes the Connection list and Connection list modification options . Connection list - Connection list shows the details of the connections such as connection setting (IP/ COM, Port No, MAC, and Connection Type), connection status, Set ID Range, and detected devices. Each connection can contain a maximum of 100 devices connected in serial daisy-chain fashion. All the LFDs detected in a connection are displayed in the Device list, where the user can make groups and send commands to detected devices. Connection list modification options - Connection modification options includes Add, Edit , Delete , and Refresh .
76 Using MDC 3 3 Using MDC 3.3.3 Auto Set ID Auto Set ID feature assigns a Set ID for all the LFDs connected in daisy-chain of a selected connection. There can be a maximum of 100 LFDs in a connection. The Set ID is assigned sequentially in the daisy- chain running from 1 to 99, and then finally to Set ID 0.
77 Using MDC 3 3 Using MDC 3.3.4 Cloning Using the Cloning feature, you can copy the setting of one LFD and apply it to multiple selected LFDs. You can select specific tab categories or all tab categories for cloning, using the copy setting option window.
78 Using MDC 3 3 Using MDC 3.3.5 Command Retry This feature is used to specify the maximum number of times the MDC command will be retried in case of there being no reply or a corrupted reply from an LFD. The retry count value can be set using the MDC options window. The retry count value must be between 1-10. The default value is 1.
79 Using MDC 3 3 Using MDC 3.3.6 Getting Started with MDC 1To start the program, click Start Programs Samsung MDC Unified . 2Click Add to add a display device. zIf the connection is established via RS232C, go to Serial and specify the COM Port.
80 Using MDC 3 3 Using MDC zIf the connection is established via Ethernet, enter the IP that was entered for the display device.