51 BCD (Binary Coded Decimal) BCD is used to express a decimal digit (0 to 9) using 4 bits. Conversion of BCD values can be done in hexadecimal calculations. Flash ROM It refers to a ROM (EEPROM) that stores programs. Since its contents can be deleted periodically, it is frequently used for equipments that deals with programs such as a PLC. How to use a register R (Relay) register (Can be bit, word or double word) Indicates the external I/O register that directly connects to the general I/O...
Page 52
52 For bit operations, such as setting, resetting, shifting, or rotating Use the M, K, and R area. You cannot perform bit operations in the W area. When you want to refer to or modify the set value of the timer or counter. Refer to or modify W2048 to W2303 or SV0 to SV255. When you want to refer to or modify the present value of the timer or counter. Refer to or modify the address area from W2304 to W2559 or from PV0 to PV255. The value holds true in STOP (PROG.) state in this area. The...
Page 53
53 Allowed Functions in Operation Modes 5=On, ◑=Flashing, ●=Off When the PROG.LED is on, you can change the user program. The INITIALIZE switch clears errors when the mode switch is set to PROG. When the mode switch is set to REMOTE and power is switched from Off to On, the previous mode of operation is restored. When debugging the user program, the mode switch should be set to REMOTE. Processor Processing Procedure Program processing procedure Program analysis Executes the program from its...
Page 54
54 Watchdog time initialization The watchdog elapsed time value is set to 0. (This value is the watchdog calculation point until the next scan.) The following illustration shows the difference between the relay board and PLC sequence processing. The relay carries out all sequences simultaneously while the PLC processes sequentially throughout the program. Processing of relay sequence (Parallel process)Processing of PLC program (Serial process)
Page 55
55 4 Installation and Wiring Installation Installation space and environment External dimensions (mm) unit (mm) 3-slot type5-slot type8-slot type10-slot type12-slot type A (mm) 205.0 276.0 381.0 452.0 522.0 B (mm) 183.8 254.2 359.8 430.2 500.6
Page 56
56 Installation location Be sure to maintain a sufficient distance from wiring ducts, and other machines below and above the module for proper ventilation. Do not install the modules stacked up or horizontally. Doing so will prevent proper cooling of the module and cause overheating inside the PLC (programmable controller). Do not install the module above devices which generate heat such as heaters, transistors or large scale resistors. In order to eliminate any effects from noise emission, power...
Page 57
57 Avoid installing the module in the following conditions Ambient temperature outside the range of 0 to 55 °C Ambient humidity outside the range of 30 to 85% RH Sudden temperature changes causing condensation Inflammable or corrosive gases Excessive airborne dust, metal particles, salinity Benzene, thinner, alcohol, other organic solvents or strong alkaline solutions such as ammonia or caustic soda Excessive vibration or shock Direct sunlight Location near high-tension wires,...
Page 58
58 NIt is recommended that you use crimped terminal for wiring. Use 2mm2 twisted pair cable or larger Use power supply wire that is thicker than 2mm2 to minimize voltage drops. Use twisted pair cable to minimize noise effects. Proper compressed connection terminal Circular type terminal (O type Lug) Circular type terminal with insulation resistance Open type terminal (Y type Lug) Power supply system Use separate wiring systems for the PLC module, I/O module, and power supply module as shown...
Page 59
59 Grounding Ground the PLC for noisy environments Connected to the metal part of backplane, the frame ground terminal is connected to a solid earth ground. Use ground wires with a minimum of 2mm 2 and the triple grounding connection which has a resistance of less than 100 Ω. The point of grounding should be as close to the PLC as possible and the ground wire should be as short as possible. If two devices share a single ground point, it may produce an adverse effect. Always use an exclusive...
Page 60
60 Input and Output Wiring Input wiring Checkpoints for input module wiring There can be limits on the number of points that can be simultaneously turned on, based on the module type. Check such limits in the specifications of each input module. In particular, be careful when using in high ambient temperature. The connection method for each type of input device including sensor is described below. Photoelectric sensors and proximity sensors Relay output type 2 wired type Internal CircuitInput...