Samsung Ht As700 User Manual
Here you can view all the pages of manual Samsung Ht As700 User Manual. The Samsung manuals for Home Theater System are available online for free. You can easily download all the documents as PDF.
Page 91
91 Logical Instructions Rotation Instructions MnemonicNameWord ladder symbolDouble word ladder symbolDescription WAND (DAND)AND (logical multiply)Store AND of S1 and S2 in D WOR (DOR)OR (logical sum)Store OR of S1 and S2 in D WXOR (DXOR)Exclusive OR (exclusive logical sum)Store exclusive OR of S1 and S2 in D WXNR (DXNR)Exclusive OR NOT (equivalence)Store exclusive OR NOT of S1 and S2 in D 1 (ON if they are equal) MnemonicInstructionWord ladder symbolDouble word ladder symbolDescription RLC...
Page 92
92 Word Conversion Instructions MnemonicNameWord ladder symbolDouble word ladder symbolDescription BCD (DBCD)BCD ConversionConvert binary value of S to BCD and store it in D. BIN (DBIN)Binary ConversionConvert BCD of S to binary number and store it in D. ENCO EncodeStore the location of the highest set bit in S in D. Note) It is different than function of SPC series (2 n + 1) DECO DecodeConvert the low-order 4-bit value of S to a power of 2 (2 s) and store it in D. SEG 7-SegmentConverts the...
Page 93
93 Bit Conversion Instructions MnemonicNameWord ladder symbolDouble word ladder symbolDescription BSET Bit SetSet N th bit of D to 1. BRST Bit ResetReset N th bit of D to 0. BNOT Bit NotInvert N th bit of D. BTST Bit TestStore the value of N th bit of D to F1.8. SUM SumStore the number of bits in S that are 1 to D. SC Set Carry Set carry bit (F1.8) to 1. RC Reset Carry Reset carry bit (F1.8) to 0. CC Complement Carry Invert carry bit (F1.8). When N=15 1 (N=0~15) W h e n N = 3...
Page 94
94 Register address data value absolute address When N=4 Move Instructions MnemonicNameWord ladder symbolDouble word ladder symbolDescription MOV MoveCopy Ns words from Sr to D. FMOV Fill MoveRepeatedly copy the value V to the Ns words starting from D. BMOV Bit MoveMove Ns bits from the bit address Sb to the bit address Db. BFMV Bit Fill MoveRepeatedly copy the bit value V to the N bits staring from the bit address Db. (V=0, 1)(N=1…256) (Db is bit address) LDR (DLDR)Load D ← (S)Store to D the...
Page 95
95 Program Control Instructions MnemonicNameWord ladder symbolDouble word ladder symbolDescription FOR (DFOR)For LoopExecute instructions in the block between FOR and corresponding NEXT. Repeat execution D times. NEXT NextDecrement D of FOR instruction by 1. If it is not zero, repeat execution from FOR instruction. JMP JumpJump to the position marked LBL L (label number). (L: 0 to 63) LBL LabelPosition jumped to by the corresponding JMP instruction. (L:0 to 63) JMPS Jump Start Jump to the JMPE...
Page 96
96 System Control Instructions MnemonicNameWord ladder symbolDouble word ladder symbolDescription INPR Input RefreshRefresh external input (Receive input signal during program execution). Ch is external input word address. OUTR Output RefreshRefresh external output (Send output signal during program execution). Ch is external output word address. WAT Watchdog Timer Clear watchdog scan time. END ENDEnd of program. This instruction is automatically added by WinGPC.
Page 97
97 Communications Control Instructions MnemonicNameWord ladder symbolDouble word ladder symbolDescription READRead Data (from shared memory of high performance module) Read NR3 words from the module memory address NR6 of the slot NN5, and write them to the words starting from RR1. WRITEWrite Data (to shared memory of high performance module)Read NR3 words from NR5, and write them to the module memory address NR2 of slot NN1. RMRDRead Remote Slave Data (from shared memory of high...
Page 99
99 7 NX-CPU700p System Product Dimensions System Dimensions unit (mm) Backplane Dimensions unit (mm) 3-slot type5-slot type8-slot type10-slot type12-slot type A (mm) 205.0 276.0 381.0 452.0 522.0 B (mm) 183.8 254.2 359.8 430.2 500.6 ¥ı 5.0*4 L7.0 27.522 .5 A unit (mm) SlotsAL 3 205.0 153.8 5 276.0 224.2 8 381.0 329.8 10 452.0 400.2 12 522.0 470.6
Page 100
100 Power Supply Module Dimensions) Processor and I/O Modules Dimensions OPEN S MSUNG POWER Programmable Controller 104.0 115.5 43.0 SAMSUNG POWER Programmable Controller OPEN NX700 unit (mm) 18 19 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 20 104 .0 115 .5 35.0 INIT TEST RUN RMT PROG RS232CTOOL RS232C COMCOM1 RS232C RS485 COM1 RS232C RS485 RUN PROG TEST BREAKERROR BATT ALARMNX-CPU 700pCPUNX-X 16DDC INNX-X 64DDC IN unit (mm)