Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Because of these differences, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Samsung Automation be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Samsung Automation cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Samsung Automation. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Samsung Automation. is prohibited. Throughout this manual we use notes to make you aware of safety considerations. WARNINGIdentifies information about practices or circumstances which may lead to serious personal injury or death, property damage, or economic loss. IMPORTANTIdentifies information that is critical for successful application and understanding of the product. ATTENTIONIdentifies information about practices or circumstances that can lead to minor personal injury, property damage, economic loss, or product malfunction. However, depending on circumstances, failure to follow the directions accompanying this symbol may also lead to serious consequences.
3 Contents 1. System Configuration ................................................. 7 NX-CPU700p PLC Features and System Configuration ............................... 7 Module Types and Combinations ............................................................... 10 Programming Tools ...................................................................................... 14 2. Hardware Features and Specifications ..................... 15 Overall Specifications ................................................................................... 15 Backplane and Expansion Cable.................................................................. 17 Processor Module ......................................................................................... 19 Power Supply Module .................................................................................. 22 I/O Modules ................................................................................................... 24 3. Addressing Overview ................................................ 35 Addressing Overview ................................................................................... 35 Bit and Word Addressing ............................................................................. 36 Double Word Addressing ............................................................................. 37 Absolute Addressing .................................................................................... 38 I/O Addressing............................................................................................... 39 Special Registers........................................................................................... 41 Timer/Counter Area ...................................................................................... 48 Processor Operation Mode .......................................................................... 52 Processor Processing Procedure ................................................................ 53 4. Installation and Wiring.............................................. 55 Installation ..................................................................................................... 55 Power Supply Module Wiring...................................................................... 57 Input and Output Wiring .............................................................................. 60 Terminal Block Type Module Wiring........................................................... 66 Connector Type Module Wiring .................................................................. 67 Safety Measures ........................................................................................... 72 NX-CPU700p Processor Module Communications Specifications ........... 73 EEPROM Backup ........................................................................................... 74 5. Test Run and Troubleshooting .................................. 75 Test Run Precautions .................................................................................... 75 Test Run Procedure ...................................................................................... 76 Test Run Flow Charts.................................................................................... 77 Inspection and Maintenance ........................................................................ 83
4 6. Programming Instructions ........................................ 87 Basic Sequence Instructions ........................................................................ 87 Timer, Counter and Shift Register Instructions .......................................... 88 Comparison Instructions .............................................................................. 89 Substitution, Increment and Decrement Instructions ................................ 89 Arithmetic Instructions ................................................................................. 90 Logical Instructions....................................................................................... 91 Rotation Instructions .................................................................................... 91 Word Conversion Instructions ..................................................................... 92 Bit Conversion Instructions .......................................................................... 93 Move Instructions ......................................................................................... 94 Program Control Instructions ...................................................................... 95 System Control Instructions ........................................................................ 96 Communications Control Instructions ........................................................ 97 7. NX-CPU700p System Product Dimensions............... 99 System Dimensions ...................................................................................... 99 Backplane Dimensions ................................................................................ 99 Power Supply Module Dimensions).......................................................... 100 Processor and I/O Modules Dimensions ................................................... 100 Specialty Module Dimensions ................................................................... 101 NX-IOLINK Module Dimensions ................................................................ 101 Decimal, Bin, Hex, BCD, Gray Code Cross-reference Table .................... 102 ASCII Code Table ........................................................................................ 103 Appendix. Communication Protocols.......................... 105 Communication Protocols for NX-CPU700p............................................. 105 Communication Protocols.......................................................................... 106 Structure of Communication Frames ........................................................ 111 Communication Program Examples ......................................................... 116
5 Safety Instructions Please read this manual and the related documentation thoroughly and familiarize yourself with product information, safety instructions and other directions before installing, operating, performing inspection and preventive maintenance. Make sure to follow the directions correctly to ensure normal operation of the product and your safety. Installation Environment WARNING• If this product is used in a situation that may cause personal injury and/or significant product damage, implement safe measures such as use of fault-safe equipment. Do not use this product under the conditions exposed to explosive gases. It may cause an explosion. ATTENTION Make sure to use an external device when configuring the protective circuit breakers for emergencies or interlock circuits. Fasten the terminal screws tightly to ensure that the cable connection is secure. Incorrect cable connection may cause overheating and product malfunction. Operate and keep the product under the allowed conditions directed in product specifications. Otherwise it may cause overheating and product malfunction. Do not disassemble or remodel the product. Otherwise it may cause an electric shock or malfunction. Do not touch the terminals when the power is on. Otherwise it may cause an electric shock. ATTENTIONDo not install your PLC system if any of the following conditions are present: Ambient temperature outside the range of 0 to 55 °C (32 to 131 °F) Direct sunlight Humidity outside the range of 30% to 85% (non-condensing) Chemicals that may affect electronic parts Excessive or conductive dust, or salinity High voltage, strong magnetic fields, or strong electromagnetic influences Direct impact and excessive vibration
6 ATTENTIONElectrostatic Discharges Under dry condition, excessive electrostatic discharges may occur. Make sure to remove electrostatic discharges by touching a grounded metal piece before touching your controller system modules. ATTENTIONCleaning Never use chemicals such as thinner because they melt, deform or discolor PCB boards. ATTENTIONPrecautions for use of power Run your PLC system only after the I/O devices and motor devices have started. (For example, first power on in the PROG mode, then change the operation mode to RUN.) Make sure to power off I/O devices after ensuring PLC operation is stopped. If you power on/off I/O devices when the PLC system is in operation, the system may malfunction because input signal noises may be recognized as normal inputs. ATTENTIONBefore powering on Make sure to follow these directions before powering on your PLC system. When installing the system, ensure that there are no metal chips or conductive fragments that stick to wiring cables. Ensure that power supply and I/O wirings and power supply voltage are all correct. Securely fasten installation and terminal screws. Set the operation mode switch to PROG mode.
7 1 System Configuration NX-CPU700p PLC Features and System Configuration System configuration Features • High-speed processing With the high-speed ASIC, the NX-CPU700p processes basic instructions at a speed of 0.2 µs per step. Runtime Editing The NX-CPU700p processor module allows you to modify instructions while operating. Built-In Real Time Clock (RTC) Built-in real time clock supports programming by time and date. POWER Programmable Controller OPEN INIT TEST RUN RMT PROG12 39 40 40 392 139 40 21 2 1 39 40 40 39 1 22 1 39 40 15 16 20 19 1817 5 7 6 8 11 10 9 12 14 132 1 3 4 15 16 20 19 1817 5 7 6 8 11 10 9 12 14 132 1 3 4 15 16 20 19 1817 5 7 6 8 11 10 9 12 14 132 1 3 4 15 16 20 19 1817 5 7 6 8 11 10 9 12 14 132 1 3 4 RS232CTOOL RS232C COM N X-C PU700pCPUNX-X64DDC INNX-X64DDC INNX-X32DDC INNX-Y32TTR OU TNX-Y16RVRY O UTN X-Y16R VRY O UTNX-Y16RVRY O UTN X-Y16R VRY O UT Processor Module (NX-CPU700p)Communication cable (NX-CBLCPU02) WinGPC PC, MMI S/W, or T/P
8 High-capacity programming and memory backup The NX-CPU700p allows you to program up to 20K words. Built-in flash EEPROM allows you to save programs separately. Self-diagnostics Self-diagnostics allows you to minimize system errors and maximize diagnostic efficiency. Maximum 1600 I/O points With a 12-slot base backplane and a 12-slot expansion backplane, you can use up to 1600 I/O points (when all I/Os are configured with 64-point digital I/O modules). Supports various I/O and specialty modules The NX-CPU700p processor module supports 24V dc input (16, 32, and 64 points), 110V ac input, 220V ac input, relay output, transistor output (16, 32, and 64 points), SSR output, A/D, D/A, RTD, TC, high-speed counter, CCU+, and SCU. WinGPC as programming tool WinGPC, which is the programming tool for NX-CPU700p processor module, lets you create, edit, download, and upload your control program, and allows you to peform processor status monitoring, force I/O, and I/O status montioring as well. It is a powerful, easy-to-use programming tool. Various I/O backplane options (up to 12 slots) The NX-CPU700p PLC allows you to choose one from 3-, 5-, 8-, 10-, or 12-slot backplanes for maximum system configuration flexibility. Built-in RS232C/RS485, 2 ports With two built-in communication ports, the NX-CPU700p processor module allows you to connect directly to computers or touch panels and exchange a high volume of data at high speed. The COM2 port supports a simple user-defined communication, and allows you to connect to barcode readers, inverters, or servo motors. (Binary communication is available.)
9 I/O Backplanes and I/O Points Flexible system configuration: 5 types of backplane (3-, 5-, 8-, 10- and 12-slot) The NX-CPU700p PLC has 5 types of backplane (3-, 5-, 8-, 10 and 12-slot type), providing you with very flexible I/O configuration. All backplanes, I/O modules, power supply, and specialty modules are available to other NX700 series PLC systems, for example, NX-CPU700 or NX-CPU750A system. Maximum 1600 I/O points With a 12-slot base backplane and a 12-slot expansion backplane, you can use up to 1600 I/O points by configuring all I/Os with 64-point digital I/O modules. 3-Slot Type 5-Slot Type 8-Slot Type 10-Slot Type 12-Slot Type NX-BASE03 48 Points: 16-point I/O 192 Points: 32-point I/ONX-BASE0) 80 Points: 16-point I/O 320 Points: 64-point I/O NX-BASE08 128 Points: 16-point I/O 512 Points: 64-point I/ONX-BASE10 160 Points: 16-point I/O 640 Points: 64-point I/O NX-BASE12 192 Points: 16-point I/O 768 Points: 64-point I/O
10 Module Types and Combinations Combinations of backplanes and modules OPEN POWER Programmable ControllerNX700 OPEN POWER Programmable ControllerNX700 OPEN POWER Programmable ControllerNX700 CP U TEST TEST BATT RUN RUN RMT PROG PROG ERROR COM1 COM2 RS485 RS232C COM 1NX-CPU700p RS485 RS232CCOM 1 INIT Backplanea 3-slot type: NX-BASE03 (common for base and expansion backplanes)Processor module Power supply modules 5-slot type: NX-BASE05 (common for base and expansion backplanes) 8-slot type: NX-BASE08 (common for base and expansion backplanes) 10-slot type: NX-BASE10 (common for base and expansion backplanes) 12-slot type: NX-BASE12 (common for base and expansion backplanes) NX-POWER 110 to 220V ac input (free voltage) 4A at 5V, 0.5A at 24VNX-PWR220 220V ac input 6A at 5VNX-PWRDC 24V dc input 5A at 5V NX-CPU700p 20k step base memory 2 ports (RS232/RS485)