    							NX700 Series Controller 
    NX-CPU700p 
    User Manual
     
    						
    							Important User Information
    Solid state equipment has operational characteristics differing from those of 
    electromechanical equipment. Because of these differences, and also because of the 
    wide variety of uses for solid state equipment, all persons responsible for applying 
    this equipment must satisfy themselves that each intended application of this 
    equipment is acceptable.
    In no event will Rockwell Samsung Automation be responsible or liable for indirect or 
    consequential damages resulting from the use or application of this equipment.
    The examples and diagrams in this manual are included solely for illustrative 
    purposes. Because of the many variables and requirements associated with any 
    particular installation, Rockwell Samsung Automation cannot assume responsibility 
    or liability for actual use based on the examples and diagrams.
    No patent liability is assumed by Rockwell Samsung Automation. with respect to use 
    of information, circuits, equipment, or software described in this manual.
    Reproduction of the contents of this manual, in whole or in part, without written 
    permission of Rockwell Samsung Automation. is prohibited.
    Throughout this manual we use notes to make you aware of safety considerations.
    WARNINGIdentifies information about practices or circumstances which may 
    lead to serious personal injury or death, property damage, or 
    economic loss.
    IMPORTANTIdentifies information that is critical for successful application and 
    understanding of the product.
    ATTENTIONIdentifies information about practices or circumstances that can lead 
    to minor personal injury, property damage, economic loss, or 
    product malfunction. However, depending on circumstances, failure 
    to follow the directions accompanying this symbol may also lead to 
    serious consequences.
     
    						
    							3
    Contents
    1. System Configuration ................................................. 7
    NX-CPU700p PLC Features and System Configuration ............................... 7
    Module Types and Combinations ............................................................... 10
    Programming Tools ...................................................................................... 14
    2.  Hardware Features and Specifications ..................... 15
    Overall Specifications ................................................................................... 15
    Backplane and Expansion Cable.................................................................. 17
    Processor Module ......................................................................................... 19
    Power Supply Module .................................................................................. 22
    I/O Modules ................................................................................................... 24
    3. Addressing Overview ................................................ 35
    Addressing Overview ................................................................................... 35
    Bit and Word Addressing ............................................................................. 36
    Double Word Addressing ............................................................................. 37
    Absolute Addressing .................................................................................... 38
    I/O Addressing............................................................................................... 39
    Special Registers........................................................................................... 41
    Timer/Counter Area ...................................................................................... 48
    Processor Operation Mode .......................................................................... 52
    Processor Processing Procedure  ................................................................ 53
    4. Installation and Wiring.............................................. 55
    Installation ..................................................................................................... 55
    Power Supply Module Wiring...................................................................... 57
    Input and Output Wiring .............................................................................. 60
    Terminal Block Type Module Wiring........................................................... 66
    Connector Type Module Wiring .................................................................. 67
    Safety Measures ........................................................................................... 72
    NX-CPU700p Processor Module Communications Specifications ........... 73
    EEPROM Backup ........................................................................................... 74
    5.  Test Run and Troubleshooting .................................. 75
    Test Run Precautions .................................................................................... 75
    Test Run Procedure ...................................................................................... 76
    Test Run Flow Charts.................................................................................... 77
    Inspection and Maintenance ........................................................................ 83
     
    						
    							4
    6. Programming Instructions ........................................ 87
    Basic Sequence Instructions ........................................................................ 87
    Timer, Counter and Shift Register Instructions .......................................... 88
    Comparison Instructions .............................................................................. 89
    Substitution, Increment and Decrement Instructions ................................ 89
    Arithmetic Instructions ................................................................................. 90
    Logical Instructions....................................................................................... 91
    Rotation Instructions .................................................................................... 91
    Word Conversion Instructions ..................................................................... 92
    Bit Conversion Instructions .......................................................................... 93
    Move Instructions ......................................................................................... 94
    Program Control Instructions ...................................................................... 95
    System Control Instructions ........................................................................ 96
    Communications Control Instructions ........................................................ 97
    7.  NX-CPU700p System Product Dimensions............... 99
    System Dimensions ...................................................................................... 99
    Backplane Dimensions  ................................................................................ 99
    Power Supply Module Dimensions).......................................................... 100
    Processor and I/O Modules Dimensions ................................................... 100
    Specialty Module Dimensions ................................................................... 101
    NX-IOLINK Module Dimensions ................................................................ 101
    Decimal, Bin, Hex, BCD, Gray Code Cross-reference Table .................... 102
    ASCII Code Table ........................................................................................ 103
    Appendix. Communication Protocols.......................... 105
    Communication Protocols for NX-CPU700p............................................. 105
    Communication Protocols.......................................................................... 106
    Structure of Communication Frames ........................................................ 111
    Communication Program Examples ......................................................... 116
     
    						
    							5
    Safety Instructions
    Please read this manual and the related documentation thoroughly 
    and familiarize yourself with product information, safety instructions 
    and other directions before installing, operating, performing 
    inspection and preventive maintenance. Make sure to follow the 
    directions correctly to ensure normal operation of the product and 
    your safety. 
    Installation Environment    
    WARNING• If this product is used in a situation that may cause 
    personal injury and/or significant product damage, 
    implement safe measures such as use of fault-safe 
    equipment.
     Do not use this product under the conditions exposed 
    to explosive gases. It may cause an explosion.
    ATTENTION Make sure to use an external device when configuring 
    the protective circuit breakers for emergencies or 
    interlock circuits.
     Fasten the terminal screws tightly to ensure that the 
    cable connection is secure. Incorrect cable connection 
    may cause overheating and product malfunction.
     Operate and keep the product under the allowed 
    conditions directed in product specifications. 
    Otherwise it may cause overheating and product 
    malfunction.
     Do not disassemble or remodel the product.
    Otherwise it may cause an electric shock or 
    malfunction.
     Do not touch the terminals when the power is on.
    Otherwise it may cause an electric shock.
    ATTENTIONDo not install your PLC system if any of the following 
    conditions are present:
     Ambient temperature outside the range of 0 to 55 °C 
    (32 to 131 °F)
     Direct sunlight
     Humidity outside the range of 30% to 85% 
    (non-condensing)
     Chemicals that may affect electronic parts
     Excessive or conductive dust, or salinity
     High voltage, strong magnetic fields, or strong 
    electromagnetic influences
     Direct impact and excessive vibration
     
    						
    							6
    ATTENTIONElectrostatic Discharges
    Under dry condition, excessive electrostatic discharges 
    may occur. Make sure to remove electrostatic 
    discharges by touching a grounded metal piece before 
    touching your controller system modules.
    ATTENTIONCleaning
    Never use chemicals such as thinner because they melt, 
    deform or discolor PCB boards.
    ATTENTIONPrecautions for use of power
     Run your PLC system only after the I/O devices and 
    motor devices have started. (For example, first power 
    on in the PROG mode, then change the operation 
    mode to RUN.)
     Make sure to power off I/O devices after ensuring PLC 
    operation is stopped.
     If you power on/off I/O devices when the PLC system 
    is in operation, the system may malfunction because 
    input signal noises may be recognized as normal 
    inputs.
    ATTENTIONBefore powering on
    Make sure to follow these directions before powering 
    on your PLC system.
     When installing the system, ensure that there are no 
    metal chips or conductive fragments that stick to 
    wiring cables.
     Ensure that power supply and I/O wirings and power 
    supply voltage are all correct.
     Securely fasten installation and terminal screws.
     Set the operation mode switch to PROG mode.
     
    						
    							7
    1
    System Configuration
    NX-CPU700p PLC Features and System 
    Configuration
    System configuration
    Features
    • High-speed processing 
    With the high-speed ASIC, the NX-CPU700p processes basic 
    instructions at a speed of 0.2 µs per step.
     Runtime Editing
    The NX-CPU700p processor module allows you to modify 
    instructions while operating.
     Built-In Real Time Clock (RTC)
    Built-in real time clock supports programming by time and date.
    POWER
    Programmable
    Controller
    OPEN
    INIT
    TEST
    RUN
    RMT
    PROG12
    39 40 40 392 139 40 21
    2 1 39 40 40 39 1 22 1 39 40
    15
    16
    20 19 1817
    5
    7 6
    8
    11 10 9
    12
    14 132 1
    3
    4
    15
    16
    20 19 1817
    5
    7 6
    8
    11 10 9
    12
    14 132 1
    3
    4
    15
    16
    20 19 1817
    5
    7 6
    8
    11 10 9
    12
    14 132 1
    3
    4
    15
    16
    20 19 1817
    5
    7 6
    8
    11 10 9
    12
    14 132 1
    3
    4
    RS232CTOOL RS232C COM
    N X-C PU700pCPUNX-X64DDC INNX-X64DDC INNX-X32DDC INNX-Y32TTR OU TNX-Y16RVRY O UTN X-Y16R VRY O UTNX-Y16RVRY O UTN X-Y16R VRY O UT
    Processor Module
    (NX-CPU700p)Communication cable 
    (NX-CBLCPU02)
    WinGPC PC,
    MMI S/W,
    or T/P
     
    						
    							8 High-capacity programming and memory backup
    The NX-CPU700p allows you to program up to 20K words. 
    Built-in flash EEPROM allows you to save programs separately.
    Self-diagnostics
    Self-diagnostics allows you to minimize system errors and 
    maximize diagnostic efficiency. 
     Maximum 1600 I/O points
    With a 12-slot base backplane and a 12-slot expansion 
    backplane, you can use up to 1600 I/O points (when all I/Os are 
    configured with 64-point digital I/O modules).  
     Supports various I/O and specialty modules
    The NX-CPU700p processor module supports 24V dc input (16, 
    32, and 64 points), 110V ac input, 220V ac input, relay output, 
    transistor output (16, 32, and 64 points), SSR output, A/D, D/A, 
    RTD, TC, high-speed counter, CCU+, and SCU.
     WinGPC as programming tool
    WinGPC, which is the programming tool for NX-CPU700p 
    processor module, lets you create, edit, download, and upload 
    your control program, and allows you to peform processor 
    status monitoring, force I/O, and I/O status montioring as well. It 
    is a powerful, easy-to-use programming tool.
     Various I/O backplane options (up to 12 slots)
    The NX-CPU700p PLC allows you to choose one from 
    3-, 5-, 8-, 10-, or 12-slot backplanes for maximum system 
    configuration flexibility.
     Built-in RS232C/RS485, 2 ports
    With two built-in communication ports, the NX-CPU700p 
    processor module allows you to connect directly to computers 
    or touch panels and exchange a high volume of data at high 
    speed. The COM2 port supports a simple user-defined 
    communication, and allows you to connect to barcode readers, 
    inverters, or servo motors. (Binary communication is available.)
     
    						
    							9
    I/O Backplanes and I/O Points 
     Flexible system configuration: 5 types of backplane (3-, 5-, 8-, 10- 
    and 12-slot)
    The  NX-CPU700p PLC has 5 types of backplane (3-, 5-, 8-, 10 and 
    12-slot type), providing you with very flexible I/O configuration.
    All backplanes, I/O modules, power supply, and specialty 
    modules are available to other NX700 series PLC systems, for 
    example, NX-CPU700 or NX-CPU750A system.
     Maximum 1600 I/O points
    With a 12-slot base backplane and a 12-slot expansion 
    backplane, you can use up to 1600 I/O points by configuring 
    all I/Os with 64-point digital I/O modules.  
    3-Slot Type 5-Slot Type
    8-Slot Type 10-Slot Type
    12-Slot Type
    NX-BASE03
    48 Points: 16-point I/O
    192 Points: 32-point I/ONX-BASE0)
    80 Points: 16-point I/O
    320 Points: 64-point I/O
    NX-BASE08
    128 Points: 16-point I/O
    512 Points: 64-point I/ONX-BASE10
    160 Points: 16-point I/O
    640 Points: 64-point I/O
    NX-BASE12
    192 Points: 16-point I/O
    768 Points: 64-point I/O
     
    						
    							10
    Module Types and Combinations
    Combinations of backplanes and modules
    OPEN
    POWER
    Programmable
    ControllerNX700
    OPEN
    POWER
    Programmable
    ControllerNX700
    OPEN
    POWER
    Programmable
    ControllerNX700
    CP U
    TEST TEST
    BATT
    RUN RUN
    RMT
    PROG PROG
    ERROR COM1
    COM2
    RS485 RS232C
    COM 1NX-CPU700p
    RS485 RS232CCOM 1
    INIT
    Backplanea
    3-slot type: NX-BASE03 
    (common for base and 
    expansion backplanes)Processor module
    Power supply modules
    5-slot type: NX-BASE05 
    (common for base and 
    expansion backplanes)
    8-slot type: NX-BASE08 
    (common for base and 
    expansion backplanes)
    10-slot type: NX-BASE10
    (common for base and 
    expansion backplanes)
    12-slot type: NX-BASE12 
    (common for base and 
    expansion backplanes)
    NX-POWER
    110 to 220V ac input 
    (free voltage)
    4A at 5V, 
    0.5A at 24VNX-PWR220
    220V ac input
    6A at 5VNX-PWRDC
    24V dc input
    5A at 5V NX-CPU700p
    20k step base memory
    2 ports (RS232/RS485)
     
    						
    All Samsung manuals Comments (0)