Home > Samsung > Home Theater System > Samsung Ht As700 User Manual

Samsung Ht As700 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Samsung Ht As700 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1705 Samsung manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							21  Operating condition setting switches
    Switch for termination resistance setting (DIP switch 1)
    Switch for communication and program booting method setting 
    (DIP switch 2)
    Pin No.Pin 
    settingDescriptionDIP Switch 1
    43
    ON ONFor RS-485 communication, set both pins 3 and 4 to On if the 
    system is a termination station. (Enables termination for COM1 
    terminal)
    OFF OFFFor RS-485 communication, set both pins 3 and 4 to Off if the system 
    is not a termination station. (Disables termination for COM1 
    terminal)
    21
    ON ONFor RS-485 communication, set both pins 1 and 2 to On if the 
    system is a termination station. (Enables termination for COM2 
    terminal)
    OFF OFFFor RS-485 communication, set both pins 1 and 2 to Off if the 
    system is not a termination station. (Disables termination for COM2 
    terminal)
    4321
    ON
    Pin No.Pin 
    settingDescriptionDIP Switch 2
    87OFF OFF Sets the communication speed on COM2 terminal to 9600 bps
    ON OFF Sets the communication speed on COM2 terminal to 19200 bps
    OFF ON Sets the communication speed on COM2 terminal to 38400 bps
    ON ON Sets the communication speed on COM2 terminal to 4800 bps
    65OFF OFF Sets the communication speed on COM1 terminal to 9600 bps
    ON OFF Sets the communication speed on COM1 terminal to 19200 bps
    OFF ON Sets the communication speed of COM1 terminal to 38400 bps
    ON ON Sets the communication speed on COM1 terminal to 4800 bps
    4ON Selects RS-485 communications for COM1
    OFF Selects RS-232C communications for COM1
    3ON Selects RS-485 communications for COM2
    OFF Selects RS-232C communications for COM2
    2 OFF Always set to Off. (Reserved for system setting)
    1ON Loads the program from EEPROM (flash ROM) at power-on.
    OFF Operates the system with the program in RAM at power-on.
    8765
    4321
    ON
     
    						
    							22
    Power Supply Module
     Hardware features
    1. Power status LED
    Turns on when power is on.
    2. Power fuse holder 
    3. Terminal block
    Terminal block for power wiring. Crimped terminal for M3.5 can be used. 
    Detachable. 
    4. Power input terminal
    110-240V AC Free Voltage power input terminal (NX-PWR220 is only for 
    220V ac).
    5. Frame ground (FG) terminal
    As a grounding terminal, it is connected to the metal part of the 
    backplane. Use triple grounding to prevent electric shock.
    6. Service power terminal (24V DC)
    DC power supply to input and output unit.
    POWER
    FUSE
    USE ONLY
    250V 1.5A
    85-264
    VAC
    FRAME
    GROUND
    24VDC
    0.5A
    OUTPUT
    N
    L
    +
    -
    1
    3
    2
    4
    5
    6
    POWER
    FUSE
    USE ONLY
    250V 1.5A
    FRAME
    GROUND
    +
    -
    24V DC
    NX-POWER NX-PWRDC 
    ATTENTIONThis service power terminal should not be connected to any 
    commercial power supplies in parallel because it causes an 
    error.
     
    						
    							23  Specifications 
     Input typeAC input power DC input power
    Catalog number
    NX-POWERNX-PWR220NX-PWRDC 
    Input rated voltage110 to 220V AC
    Free Voltage220V AC 24V DC
    Allowed voltage range 85 to 264V AC 176 to 264V AC 24V DC 
    ± 10 %
    Input power frequency 47 to 63Hz
    Inrush current 20A or less
    Rated output current 5V 4.0A, 24V 0.5A 5V 6.0A 5V 3.0A
    Fuse 250V 1.5A
    Weight 350g 300g 320g
    ATTENTIONNX-POWER module does not guarantee protection against 
    momentary power failure at 110V ac.
    ATTENTIONMake sure that total current consumption of all modules 
    mounted on the backplane does not exceed the rated 
    current capacity of the power supply module.
     5V power is supplied from the power supply module 
    mounted on the same backplane.
     The 24V control power is used for supplying a dc power to 
    I/O module.
     Do not connect this 24V control power with other 
    commercial power supplies in parallel. It may cause error 
    or product malfunction.
     A 250V 1A fuse is used for AC power. (The fuse is built 
    into the power supply module.)
     Be careful that the 24V side on the external terminal does 
    not exceed the current capacity. (It may cause system 
    errors.)
     
    						
    							24
    I/O Modules 
     Hardware features
    1. I/O Status LED
    Shows I/O ON/OFF status.
    2. Terminal block fixing screw
    Fixes detachable terminal block on the unit.
    3. Terminal block (20P, detachable terminal block)
    Terminal block for I/O and power wiring. Crimped terminal for M3.5 can 
    be used. See Terminal Block Type Module Wiring in Chapter 4.
    4. Connector 32 points (40P x 1), Connector 64 points (40P x 2)
    Connector for I/O contact and power wiring. Use harness for PIN type or 
    flat cable. See Connector Type Module Wiring in Chapter 4 for details.
    5. Indication shift switch (64 points unit) 
    Convert the 64-point unit LED into front 32 points and rear 32 points.
    NX-Y64TTR OUT
    1
    2
    3
    4
    1
    0
    5
    4
    7
    F 8
    10 17
    1F 18
    1
    ¥–
    ¥
    40 39 1 2
    240
    39
    1
    DC INNX-X16D
    0
    8F7
    TR OUTNX-Y32T07
    F 8
    10 17
    1F 18
    1       2
    39    40
    16-point type
    (A Type)32-point type
    (B Type)64-point type
    (C Type)
     
    						
    							25
    Input unit specifications
    Internal circuit and wiring diagram
    Product nameDC input module
    Catalog numberNX-X16D
    Number of input points 16 points 
    Insulation method Photocoupler
    Rated input voltage 12 to 24V
    Operating voltage range 10.2 to 26.4V
    Max. input current 10mA or less (for 24V)
    ON voltage/current Min. 9.6V 
    OFF voltage/current Max. 2.5V
    Input impedance: Approx. 3 K
    Ω
    Response timeOFF → ON 10ms or less
    ON → OFF 10ms or less
    Internal current consumption (5V) 65mA or less
    Common method 8 points/1COM (Common for polarity +, -)
    Operation indicator LED
    External cable connection typeTerminal block connection (M3.5), Detachable 
    terminal block (20 pins) 
    Recommended cable size 0.5 to 1.25 mm
    2
    Capacity 170g
    Ty p e s ( A )  Ty p e
    NC: No Connection 12V to 24V DC
    12V to 24V DC
     
    						
    							26
    Wiring diagram Internal circuit
    Product nameDC input module
    Catalog numberNX-X32D
    Number of input points 32 points 
    Insulation method Photocoupler
    Rated input voltage 12 to 24V
    Use voltage range 10.2 to 26.4V
    Max. input current 10mA or less (for 24V)
    ON voltage/current Min. 9.6V 
    OFF voltage/current Max. 2.5V
    Input impedance Approx. 3 K
    Ω
    Response timeOFF → ON 10ms or less
    ON → OFF 10ms or less
    Internal current consumption (5V) 130mA or less
    Common method 32 points/1COM (Common for polarity +, -)
    Operation indicator LED
    External cable connection type Connector (40 pin x 1 EA)
    Recommended cable size 0.2 mm
    2
    Capacity 140g
    Ty p e s ( B )  Ty p e
    0 to 1F
    COM
    24V
    DC
    12
    34
    56
    78
    910
    1112
    1314
    1516
    1718
    1920
    2122
    2324
    2526
    2728
    2930
    3132
    3334
    3536
    3738
    3940
    X1 X0
    XEXF
    X10X11
    X1EX1F
    COM
    COM COM
    COMNC
    NC NC NC2
    4
    6
    8
    A
    C
    12
    14
    16
    18
    1A
    1C3
    5
    7
    9
    B
    D
    13
    15
    17
    19
    1B
    1D
    NThe COM terminal of a connector has a 
    short inside of the unit. 
    NFor wiring method, See Terminal Block 
    Type Module Wiring in Chapter 4. 
    NUse separate commercial cable harness 
    (NX-CBLDC) and Pin Type Assy 
    (CPL8890) for external connection.
    NNC: No Connection
     
    						
    							27
    Wiring diagram
    Internal circuit
    Same as NX-X32D. 
    NThe connectors [I] and [II] have opposite orientation each other, so be 
    careful with wiring. 
    NThe COM terminal of the connector has a short inside of the unit. 
    NFor wiring method, See Terminal Block Type Module Wiring in Chapter 4. 
    NUse separate commercial cable harness (NX-CBLDC) and Pin Type Assy 
    (CPL8890) for external connection.
    NNC: No Connection
    Product nameDC input module
    Catalog numberNX-X64D
    Number of input points 64 points 
    Insulation method Photocoupler
    Rated input voltage 12 to 24V
    Operating voltage range 10.2 to 26.4V
    Max. input current 10mA or less (for 24V)
    ON voltage/current Min. 9.6V 
    OFF voltage/current Max. 2.5V
    Input impedance Approx. 3 K
    Ω
    Response timeOFF → ON 10ms or less
    ON → OFF 10ms or less
    Internal current consumption (5V) 250mA or less
    Common method 32 points/1COM (Common for polarity +, -)
    Operation indicator LED indication (display by 32 points conversion)
    External cable connection type Connector (40 pin x 2 EA)
    Recommended cable size 0.2 mm
    2
    Capacity 200g
    Ty p e s ( C )  Ty p e
    (I)(II)
    24V
    DC
    12
    34
    56
    78
    910
    1112
    1314
    1516
    1718
    1920
    2122
    2324
    2526
    2728
    2930
    3132
    3334
    3536
    3738
    3940
    X1 X0
    XEXF
    X10X11
    X1EX1F
    COM
    COM COM
    COMNC
    NC NC NC2
    4
    6
    8
    A
    C
    12
    14
    16
    18
    1A
    1C3
    5
    7
    9
    B
    D
    13
    15
    17
    19
    1B
    1D 24V
    DC
    4039
    3837
    3635
    3433
    3231
    3029
    2827
    2625
    2423
    2221
    2019
    1817
    1615
    1413
    1211
    109
    87
    65
    43
    21
    X1 X0
    XEXF
    X10X11
    X1EX1F
    COM
    COM COM
    COM
    NC
    NC NC NC
    2
    4
    6
    8
    A
    C
    12
    14
    16
    18
    1A
    1C3
    5
    7
    9
    B
    D
    13
    15
    17
    19
    1B
    1D
     
    						
    							28
    Wiring diagram  Internal circuit
    Product nameAC input module
    Catalog numberNX-X16A110 NX-X16A220
    Number of input points 16 points 
    Insulation method Photocoupler
    Rated input voltage AC 100 to 120V AC 200 to 240V
    Operating voltage range AC 85 to 132V AC 170 to 264V
    Max. input current 20mA or less
    ON voltage/current Min. 80V/6mA  Min. 160V/6mA
    OFF voltage/current Max. 30V/3mA  Max. 50V/3mA 
    Input impedance Approx. 15K
    ΩApprox. 20KΩ
    Response timeOFF → ON 15ms or less
    ON → OFF 20ms or less
    Internal current consumption (5V) 60mA or less
    Common method 8 points/1COM 
    Operation indicator LED
    External cable connection typeTerminal block connection (M3.5), Detachable 
    terminal block (20 pins)
    Recommended cable size 0.5 to 1.25 mm
    2
    Capacity 200g
    Ty p e s ( A )  Ty p e
    0F
    COM
    AC100  to 120V
    NC: No Connection
    NX-X16A220: 200-240V ACNOTE
     
    						
    							29
    Output module specifications
    Internal circuit and wiring diagram
    NX-Y16R: No varistor
    NX-Y16RV: Varistor
    Product nameRELAY output module
    Catalog numberNX-Y16R NX-Y16RV
    Number of output points 16 points 
    Insulation method Photocoupler
    Rated load voltage 2A 250V AC, 2A 30V DC 
    Response timeOFF → ON 10ms or less
    ON → OFF 10ms or less
    Life timeMechanical 30 million times
    Electric 200 thousand times
    External power supply 24V 150mA or less
    Surge protection N/A Varistor
    Internal current consumption (5V) 120mA or less
    Common method 8 points/1COM 
    Operation indicator LED
    External cable connection typeTerminal block connection (M3.5), Detachable 
    terminal block (20 pins) 
    Recommended cable size 0.5 to 1.25 mm
    2
    Capacity 225g 235g
    Ty p e s ( A )  Ty p e
    250V AC
    30V DC
    24V DC
    Va r i s t o r
     
    						
    							30
    Wiring diagram
    Internal circuit
    Same as NX-Y16RV. 
    NThe COM terminal of the connector has a short inside of the unit. 
    NFor wiring method, See Terminal Block Type Module Wiring in Chapter 4. 
    NUse separate commercial cable harness (NX-CBLRY) and Pin Type Assy 
    (CPL8890) for external connection.
    Product nameRELAY output module
    Catalog numberNX-Y32RV
    Number of output points 32 points 
    Insulation method Photocoupler
    Rated load voltage 1A 250V AC, 1A 30V DC
    Response
    timeOFF → ON 10ms or less
    ON → OFF 10ms or less
    Life timeMechanical 30 million times
    Electric 200 thousand times
    External power supply 24V 150mA or less
    Surge protection circuit Varistor
    Internal current consumption (5V) 180mA or less
    Common method 32 points/1COM 
    Operation indicator LED
    External cable connection type Connector (40 pin x 1 EA)
    Recommended cable size 0.2 mm
    2
    Capacity 300g
    Ty p e s ( B )  Ty p e
    12
    34
    56
    78
    910
    1112
    1314
    1516
    1718
    1920
    2122
    2324
    2526
    2728
    2930
    3132
    3334
    3536
    3738
    3940
    Y1 Y0
    YEYF
    Y10Y11
    Y1EY1F
    COM
    COM COM
    COM2
    4
    6
    8
    A
    C
    12
    14
    16
    18
    1A
    1C3
    5
    7
    9
    B
    D
    13
    15
    17
    19
    1B
    1D
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    L
    24V DC+
    24V DC-
    24V DC- 24V DC+
    Max. 
    250V AC
    30V DC 
     
    						
    All Samsung manuals Comments (0)

    Related Manuals for Samsung Ht As700 User Manual