Operation Runco X-400d/X-450d Installation/Operation Manual 85 PREL IMINARY Splash Enable: When you have finished customizing the splash screen, select Splash Enable from the Splash Configure menu. Then, select On and press ENTER. OSD Position: To adjust the position of the OSD, select OSD Position from the Calibration menu and press ENTER. Press or to select “Hor.” or “Ver.” Then, press or to change the position. Service Use the Service menu to access advanced projector configuration...
Page 102
Operation 86 Runco X-400d/X-450d Installation/Operation Manual PREL IMINARY Press MENU to exit test pattern mode. Grey BarsUse this pattern when making brightness, contrast or white balance (gain/offset) adjustments. Full WhiteUse this pattern when measuring or adjusting brightness, contrast or white balance (gain/offset). Primary Alignment Secondary Alignment Dual AlignmentUse this pattern when aligning the output from the projector’s primary or secondary optical engines (refer to Adjusting...
Page 103
Operation Runco X-400d/X-450d Installation/Operation Manual 87 PREL IMINARY Input Names: You can give each input a descriptive name. For example, you may want to change the default input name to the type of source component connected to it: “VCR,” “DVD,” “Laptop” et cetera. Input names can be up to 12 characters long. To edit an input name, select Input Names from the Service menu. Press or to select an input and press ENTER. Use the or buttons to change a character; press or to select a...
Page 104
Operation 88 Runco X-400d/X-450d Installation/Operation Manual PREL IMINARY When you change the Remote Code on the Dimension Digital Controller, you must re-program the Dimension Digital Controller remote control to send that same code. To enable “extended” key code mode, you must re-program the Dimension Digital Controller remote control with a special five-digit code reserved for that purpose. To do this: 1. Press and hold the LIGHT button on the remote control for approximately five seconds, or...
Page 105
Operation Runco X-400d/X-450d Installation/Operation Manual 89 PREL IMINARY To change a button assignment, select the corresponding entry in the SRC 1-7 Keys or SRC 8-14 Keys sub-menu. Then, choose the source input you wish to assign to that button. Display Device - Configure: The options in the Display Device - Configure menu allow you to change the picture orientation, perform lens adjustments or access other, display-device specific functions. stallation – Orientation: Select Installation from...
Page 106
Operation 90 Runco X-400d/X-450d Installation/Operation Manual PREL IMINARY splay 3D Settings: The Display 3D Settings menu is not applicable to the X-400d/X-450d. Internal 3D Settings: Select Internal 3D Settings from the Display Device - Configure menu to adjust the following timing settings for the Dimension Digital Controller’s 3D Sync output (see Figure 2-5 and Figure 3-26), to optimize performance of the glasses, emitter and projector, for realistic simulation and 3D images.. Sync Delay: This...
Page 107
Operation Runco X-400d/X-450d Installation/Operation Manual 91 PREL IMINARY Default Gateway: Select Default Gateway from the IP Configuration menu to manually configure the default IP gateway. The procedure is similar to that for setting the IP address. Communication Test: Select Communication Test from the IP Configuration menu to verify proper operation of the network communication link. To start the test, select Start Test from the Communication Test menu. The Dimension Digital Controller...
Page 108
Operation 92 Runco X-400d/X-450d Installation/Operation Manual PREL IMINARY E-Mail Notification: Select E-Mail Notification from the Network menu to specify when and to whom the Dimension Digital Controller sends error and service notification messages via e-mail. The notification messages are in the following format: To: [E-Mail Address; see below] From: [email protected] Subject: [Type of notification] from Runco DC-300 Body: This is an automated message sent from the Runco DC-300:...
Page 109
Operation Runco X-400d/X-450d Installation/Operation Manual 93 PREL IMINARY Periodic Service Notification: You can have the Dimension Digital Controller send periodic reminders via e-mail to perform regular maintenance tasks. To do this: 1. Select Periodic Service Notification from the E-Mail Notification menu. 2. Highlight Enable and press ENTER. 3. Highlight On and press ENTER. 4. Press MENU. 5. Highlight Timer and press ENTER. 6. Press or to set the notification interval in months. The range...
Page 110
Operation 94 Runco X-400d/X-450d Installation/Operation Manual PREL IMINARY Remote Network Control: Select Remote Network Control from the Network menu to enable or disable control of the Dimension Digital Controller via an IP connection (typically using a web browser). Set it to On to allow all incoming remote network connectivity. Set it to Off to disable any incoming network communication that was not initiated by the Dimension Digital Controller. Color Space: Select Color Space from the Service...