Runco X 450d Projector User Manual
Here you can view all the pages of manual Runco X 450d Projector User Manual. The Runco manuals for Projector are available online for free. You can easily download all the documents as PDF.
Page 121
Runco X-400d/X-450d Installation/Operation Manual 105 PREL IMINARY In addition to using the Dimension Digital Controller front-panel keypad or remote control unit, there are three methods of controlling the X-400d/X-450d and Dimension Digital Controller externally: Using a serial (RS-232) or TCP/IP (Ethernet) link to send ASCII commands and receive responses to those commands. Using discrete infrared (IR) codes to program a third-party remote control unit. Using an HDMI connection to send...
Page 122
External Control 106 Runco X-400d/X-450d Installation/Operation Manual PREL IMINARY Command FormatCommands sent from an automation/control system or PC to the Dimension Digital Controller must have the following format: (www:xyz) [CR] Where: ( and ) indicate the start and end of the command data. If these characters are present, the Dimension Digital Controller assumes that valid command data is present in the command string. Otherwise, the Dimension Digital Controller ignores the command. www...
Page 123
External Control Runco X-400d/X-450d Installation/Operation Manual 107 PREL IMINARY 11 = Password not entered www indicates the command code. This field is case insensitive; for example, PWR, pwr and PwR are all equivalent. :x is the destination parameter. This is an optional parameter that indicates which memory the command is referencing. This parameter is reserved for future use. z is the new value (for Set, Increment or Decrement commands) or the current value (for Get commands) for this...
Page 124
External Control 108 Runco X-400d/X-450d Installation/Operation Manual PREL IMINARY Apply Image Alignment Values AIA R/W No 0 1 No 0 = Off; 1 = On Altitude ALT R/W No 0 1 No 0 = Auto 1 = High Advanced Color Temp Mode EnableAME R/W No 0 1 No 0 = Off; 1 = On Auto New Firmware Check ANF R/W No 0 1 No 0 = Off; 1 = On Auto Power Off Enable APE R/W No 0 2 No 0 = Off; 1 = On; 2 = No Signal Auto Power Off Timer APT R/W Yes 1 24 No Auto Perform Upgrade APU R/W No 0 1 No 0 = Off; 1 = On Aspect Ratio Copy ARC W No...
Page 125
External Control Runco X-400d/X-450d Installation/Operation Manual 109 PREL IMINARY ConstantContrast (X-400d only)CCT R/W No 0 4 No 0 = Off 1 = On 2 = Low 3 = Medium 4 = High CEC Enable CEC R/W No 0 1 No 0 = Off; 1 = On Chroma Delay CHR R/WYes07No Color Gamut CLG R/WYes06No0 = Auto 1 = REC709 2 = SMPTE C 3 = EBU 4 = Native 6 = PCE Color Offset CLO R/W Yes -50 50 No Picture menu Color CLR R/W Yes -50 50 No Calibration -> Input Image menu Color Space CLS R/W No 0 4 No 0 = REC601 1 = REC709 2 = RGB 3 = RGB...
Page 126
External Control 110 Runco X-400d/X-450d Installation/Operation Manual PREL IMINARY Diagnostic Color DGC R/W No 0 6 No 0 = White 1 = Red 2 = Green 3 = Blue 4 = Yellow 5 = Cyan 6 = Magenta Display Green Gain DGG R/W Yes -100 100 No Display Green Offset DGO R/W Yes -100 100 No DHCP DHC R/W No 0 1 No 0 = Off; 1 = On Display Red Gain DRG R/W Yes -100 100 No Display Red Offset DRO R/W Yes -100 100 No Error Notification ERN R/W No 0 1 No 0 = Off; 1 = On Error Code ERR R No 0 No 0 = None 1 = Display Lamp...
Page 127
External Control Runco X-400d/X-450d Installation/Operation Manual 111 PREL IMINARY 24Hz 3D Mode FRC R/W No 1 2 No 1 = 120Hz 6:4 2 = 120Hz 5:5 Firmware Upgrade FWU W No N/A N/A No Action will be performed on any setting value Gamma Advanced GMA R/W Yes 0 20 No Gamma Mode GMM R/W No 0 1 No 0 = Simple 1 = Advanced Gamma Simple GMS R/W No 0 4 No 0 = 2.0 1 = 1.8 2 = 2.2 3 = 2.35 4 = 2.5 HDMI Audio Format HAF R/W No 0 3 No 0 = Combined 1 = HDMI Out (Pri. Display) 2 = HDMI Out (Sec. Display) 3 = HDMI Out...
Page 128
External Control 112 Runco X-400d/X-450d Installation/Operation Manual PREL IMINARY Information Copied Aspect Ratio ICA R No N/A N/A Yes Information Current Color Space ICC R No 0 3 Yes 0 = REC601 1 = REC709 2 = RGB 3 = RGB Video Information Copied Input Source ICI R No N/A N/A Yes Information Copied Memory Pre- setICM R No N/A N/A Yes Information Copied Screen ICR R No N/A N/A Yes Information Copied Signal Format ICS R No N/A N/A Yes Information Display Name IDN R No N/A N/A Yes Information Firmware...
Page 129
External Control Runco X-400d/X-450d Installation/Operation Manual 113 PREL IMINARY Input Position Height IPH R/W Yes 0 20 No Input Position Left Right IPL R/W Yes -50 50 No Input Position Up Down IPU R/W Yes -50 50 No Input Position Width IPW R/W Yes 0 50 No Input Red Gain IRG R/W Yes -32 32 No Input Red Offset IRO R/W Yes -32 32 No Internal 3D Sync Delay ISD R/W Yes Var. Var. No Information Signal Format ISF R No N/A N/A Yes Information Serial Number ISN R No N/A N/A Yes Information Sync Type IST R No...
Page 130
External Control 114 Runco X-400d/X-450d Installation/Operation Manual PREL IMINARY Remote Key KEY W No 0 85 No 1 = On 2 = Off 3 = Menu 4 = Enter 5 = Up 6 = Down 7 = Left 8 = Right 9 = 16:9 10 = 4:3 11 = Letterbox 12 = VirtualWide 13 = Video 1 14 = Component 17 = HD 1 18 = HD 2 19 = HDMI 1 20 = HDMI 2 21 = HDMI 3 22 = HDMI 4 23 = SCART 24 = Video 2 25 = Video 3 32 = Sleep Timer Off 33 = Sleep Timer 30 Mins 34 = Sleep Timer 60 Mins 35 = Sleep Timer 90 Mins 36 = Sleep Timer 2 Hours 37 = Sleep Timer 4...