Page 631
SM 5-243 B230/B237/D042 Service Tables ƒ This name is customer informati on and is not printed in the SMC report. CERT: Up State Displays the status of the certification update. 0 The certification used by Cumin is set correctly. 1 The certification request (setAu thKey) for update has been received from the GW URL and certificat ion is presently being updated. 2 The certification update is complet ed and the GW URL is being notified of the successful update. 3 The certification update...
Page 632
B230/B237/D042 5-244 SM completed, but an certification error has been received, and the rescue certification is being recorded. 18 The rescue certification of No. 17 has been recorded, and the GW URL is being notified of the failure of the certification update. CERT: Error Displays a number code that describes the reason for the request for update of the certification. 0 Normal. There is no request for certification update in progress. 1 Request for certification update in progress. The...
Page 633
SM 5-245 B230/B237/D042 Service Tables firmware update is done with the firmware files from the URL. 086 Firmware Size Allows the service technician to confirm the size of the firmware data files during the firmware update execution. 087 CERT: Macro Version Displays the macro version of the NRS certification. 088 CERT: PAC Version Displays the PAC version of the NRS certification. 089 CERT: ID2 Code Displays ID2 for the NRS certification. Spaces are displayed as underscores (_)....
Page 634
B230/B237/D042 5-246 SM ƒ SP5816-161 0: Japan, 1: USA, 2: Canada, 3: UK, 4: Germany, 5: France, 6: Italy, 7: Netherlands, 8: Belgiu m, 9: Luxembourg, 10: Spain Line Type Authentication Judgment 151 Touch [Execute]. Setting this SP classifies the telephon e line where Cumin-M is connected as either dial-up or push type, so Cumi n-M can automatically distinguish the number that connects to the outside line. ƒ The current progress, success, or failure of this execution can be displayed with...
Page 635
SM 5-247 B230/B237/D042 Service Tables 0: Tone Dialing Phone 1: Pulse Dialing Phone Inside Japan 2 may also be displayed: 0: Tone Dialing Phone 1: Pulse Dialing Phone 10PPS 2: Pulse Dialing Phone 20PPS Outside Line/Outgoing Number 154 The SP sets the number that switches to PSTN for the outside connection for Cumin-M in a system that employs a PBX (internal line). ƒ If the execution of SP5816 151 has succeeded and Cumin-M has connected to the external line, this SP display is...
Page 636
B230/B237/D042 5-248 SM connected. This number is transmitted to and used by the Call Center to return calls. Limit: 24 numbers (numbers only) Connection Timing Adjustment: Incoming 162 When the Call Center calls out to a Cu min-M modem, it sends a repeating ID tone (*#1#). This SP sets the line remains open to send these ID tones after the number of the Cumin-M modem is dialed up and connected. [0 to 24 / 1 / 1 /step] The actual amount of time is this setti ng x 2 sec. For example, if you...
Page 637
SM 5-249 B230/B237/D042 Service Tables Normally, it is best to allow unlimited time for certification and ID2 update requests, and for the notific ation that the certification has been completed. However, Cumin-M generates charges based on transmission time for the customer, so a limit is placed upon the time allowed for these transactions. If these transactions cannot be completed within the allowed time, do this SP to cancel the time restriction. 175 Modem Modulation Mode Setting FAX TX...
Page 638
B230/B237/D042 5-250 SM 1: Inquiry number error 2: Registration in progress 3: Proxy error (proxy enabled) 4: Proxy error (proxy disabled) 5: Proxy error (Illegal user name or password) 6: Communication error 7: Certification update error 8: Other error 9: Inquiry executing Confirm Place 205 Displays the result of t he notification sent to the device from the GW URL in answer to the inquiry request. Displayed only when the result is registered at the GW URL. 206 Register Execute Execut...
Page 639
SM 5-251 B230/B237/D042 Service Tables -11002 Chat execution error Parameter -11003 Unexpected error -12002 Inquiry, registration attempted without acquiring device status. -12003 Attempted registration without execution of an inquiry and no previous registration. Operation Error, Incorrect Setting -12004 Attempted setting with illegal entries for certification and ID2. -2385 Attempted dial up overseas without the correct international prefix for the telephone number. -2387 Not...
Page 640
B230/B237/D042 5-252 SM 5821 [Remote Service Address] 001 CSS-PI Device Code Sets the PI device code. After you change this setting, you must turn the machine off and on. [0 to 4 / 0 / 1 /step] 002 RCG IP Address *CTL Sets the IP address of the RCG (Remote Communication Gate) destination for call processing at the remote service center. [NV-RAM Data Upload] 5824 Uploads the UP and SP mode data (except for counters and the serial number) from the NVRAM to an SD card . For...