Page 601
SM 5-213 B230/B237/D042 Service Tables 006 Factory Setting: GO BW *ENG Displays the factory setting values of the black level adjustment (rough adjustment) for the odd green signal in the CCD circuit board (black and white printing speed). 007 Factory Setting: GE BW *ENGDisplays the factory setting values of the black level adjustment (fine adjustment) for the even green signal in the CCD circuit board (black and white printing speed). [0 to 255 / 128 / 1 digit/step] 008 Factory...
Page 602
B230/B237/D042 5-214 SM the odd blue signal in the CCD circuit board (color printing speed). 005 Factory Setting: BE BW *ENGDisplays the factory setting values of the black level adjustment (rough adjustment) for the even blue signal in the CCD circuit board (black and white printing speed). [0 to 255 / 11 2 / 1 digit/step] 006 Factory Setting: BO BW *ENG Displays the factory setting values of the black level adjustment (rough adjustment) for the odd blue signal in the CCD circuit board...
Page 603
SM 5-215 B230/B237/D042 Service Tables [Gain Adjustment] 4678 Displays the factory setting values of the gain adjustment for Green. 001 Factory Setting: GE Color *ENG 002 Factory Setting: GO Color *ENG 003 Factory Setting: GE BW *ENG 004 Factory Setting: GO BW *ENG [0 to 255 / 0 / 1 digit/step] [Gain Adjustment] 4679 Displays the factory setting values of the gain adjustment for Blue. 001 Factory Setting: BE Color *ENG 002 Factory Setting: BO Color *ENG 003 Factory...
Page 604
B230/B237/D042 5-216 SM [Gray Balance Set: B] DFU 4687 Adjusts the gray balance of the blue signal for each scanning mode. 001 Book Read *ENG 002 DF Read *ENG [-512 to 511 / -240 / 1 digit/step] [DF: Density Adjustment] 4688 Adjusts the white shading parameter when scanning an image with the ARDF. Adjusts the density level if the ID of outputs made in the DF and Platen mode is different. 001 - *ENG [50 to 150 / 109 / 1 %/ step ] [White Level Peak Read] 4690 Displays the...
Page 605
SM 5-217 B230/B237/D042 Service Tables [White Level Peak Read] 4692 Displays the peak level of the white level scanning. 001 BE - 002 BO - 003 BE: Bk - 004 BO: Bk - [0 to 1024 / 0 / 1 digit/step] [Black Level Peak Read] 4693 Displays the peak level of the black level scanning. 001 RE - 002 RO - 003 RE: Bk - 004 RO: Bk - [0 to 1024 / 0 / 1 digit/step] [Black Level Peak Read] 4694 Displays the peak level of the black level scanning. 001 GE - 002 GO - 003 GE: Bk -...
Page 606
B230/B237/D042 5-218 SM 002 BO - 003 BE: Bk - 004 BO: Bk - 4802 [DF Shading FreeRun] 001 Lamp ON 002 Lamp OFF - Executes the scanner free run of shading movement with exposure lamp on or off. Press OFF to stop this free run. Otherwise, the free run lasts. 4804 [Home Position] 001 Lamp ON - Executes the scanner HP detection. 4806 [Carriage Save] 001 Lamp ON - Moves the carriage from the scanner home position. Dust may fall through the DF exposure glass....
Page 607
SM 5-219 B230/B237/D042 Service Tables 005 G DATA2 *ENG Photo M Patch Level 17(8-bit) 006 B DATA2 *ENG Photo Y Patch Level 17 (8-bit) 4904 [Scanner IPU Board Test] Te s t 1 - Bit0: TAURUS register Bit1: ORION register Bit2: LUPUS register Bit3: Not used Bit4: Strix register Bit5 to 15: Not used 0: OK, 1: Error 001 Performs a write and read check of th e ASICs on the BICU board and displays the result. Te s t 2 - Bit0: Image path from SBU to TAURUS Bit1: Image path from...
Page 608
B230/B237/D042 5-220 SM 4907 [SBU Test Pattern Change] Test Pattern: R - [0 to 255 / 0 / 1 /step] 0: Default (Scanning Image) 1: Grid pattern 2: Gradation main scan 3: Gradation sub scan 4 to 250: Default (Scanning Image) 4907 1 Selects the test pattern gener ated by the controller board. 4918 [Manual Gamma Adj.] Adjusts the offset data of the prin ter gamma for yellow in Photo mode. See “Replacement and Adjustment – Gamma Correction – Copy Mode” for how to use. 001 Offset:...
Page 609
SM 5-221 B230/B237/D042 Service Tables [IPU Image Pass Selection ] 4991 Selects the image path. Enter the number to be selected using the 10-key pad. RGB Frame Memory *ENG [0 to 9 / 5 / 1 /step ] 001 0: Scanner input RGB images 1: Scanner I/F RGB images 2: RGB images done by Shading correction (Shading ON, Black offset ON) 3: Shading data 4: Inner pattern data: Gray scale 5: RGB images done by Line skipping correction 6: RGB images done by Digital AE 7: RGB images done by Vertical...
Page 610
B230/B237/D042 5-222 SM text/photo 0: Text priority 1: Normal 2: Photo priority SP5-XXX (Mode) [mm/inch Display Selection] 5024 Display units (mm or inch) for custom paper sizes. 001 0:mm 1:inch *CTL0: mm (Europe/Asia) 1: inch (USA) [Accounting Counter] 5045 Selects the counting method. NOTE: The counting method can be changed only once, regardless of whether the counter value is negative or positive. 001 Counter Method *CTL [0 or 1 / 0 / - ] 0: Developments 1: Prints...