Page 571
SM 5-183 B230/B237/D042 Service Tables 008 With Developer *ENG [0 to 5 / 1.3 / 0.1 V/step] 009 Serial Number 1 *ENG 010 Serial Number 2 *ENG [0 to 255 / - / 1 V/step] 011 Adjustment: Vt *ENG [0 to 5 / 3 / 0.1 V/step] 012 Adjustment: Vtref *ENG [0 to 5 / 3 / 0.1 V/step] 013 Adjustment: Vtcnt *ENG [0 to 5 / 4 / 0.01 V/step] 014 Adjustment: Gamma *ENG [0 to 2.55 / 0 / 0.01 mg/cm2/kV /step] 015 Adjustment: Vcnt Result *ENG [0 to 9 / 9 / 1 /step] [HST Concentration Control: C] 3713...
Page 572
B230/B237/D042 5-184 SM 014 Adjustment: Gamma *ENG [0 to 2.55 / 0 / 0.01 mg/cm2/kV /step] 015 Adjustment: Vcnt Result *ENG [0 to 9 / 9 / 1 /step] [HST Concentration Control: Y] 3714 Displays the factory settings of the yellow PCU. 001 Vcnt *ENG [0 to 5 / 4 / 0.1 V/step] 002 Vt *ENG [0 to 5 / 2.5 / 0.1 V/step] 003 Sensitivity: HL *ENG [0 to 5 / 2.5 / 0.1 V/step] 004 Sensitivity: HM *ENG [0 to 5 / 1.3 / 0.1 V/step] 005 Sensitivity: ML *ENG [0 to 5 / 1.2 / 0.1 V/step] 006 Set...
Page 573
SM 5-185 B230/B237/D042 Service Tables 001 Condition *CTL [0 to 4 / 0 / 1 /step] 002 Detection Times *CTL [0 to 50 / - / 1 /step] 003 Print Page After Near Full *CTL [0 to 1000 / 0 / 1 sheet/step] 004 Pixel Count After Near Full *CTL [0 to 200000 / - / 1 cm2/step] 005 Pixel Count After Replacement *CTLDisplays the pixel counter after replacement of toner collection bottle. [0 to 200000 / - / 1 cm 2/step] 008 Coefficient *ENG [0.5 to 1.5 / 1 / 0.1 /step] 011 Notice Setting...
Page 574
B230/B237/D042 5-186 SM 0: OFF, 1: ON [Manual New Unit Set] 3902 Turns the new unit detection flag for each PM unit on or off. The use of these counters is explained in the PM section and in the relevant parts of section 3 (Replacement and Adjustment). 001 Development Unit: Bk *ENG 002 Development Unit: Y *ENG 003 Development Unit: C *ENG 004 Development Unit: M *ENG [0 or 1 / 0 / - ] 0: OFF, 1: ON 005 Developer: Bk *ENG 006 Developer: Y *ENG 007 Developer: C *ENG 008 Developer: M...
Page 575
SM 5-187 B230/B237/D042 Service Tables SP4-XXX (Scanner) [Sub Scan Magnification Adjustment] 4008 Adjusts the sub-scan magnification by changing the scanner motor speed. 001 Sub Scan Magnification Adjustment *CTL [-1.0 to 1.0 / 0 / 0.1%/step] FA [Leading Edge Registration Adjustment] 4010 Adjusts the leading edge registration by changing the scanning start timing in the sub-scan direction. 001 *CTL [-2.0 to 3.0 / 0 / 0.1 mm/step] FA [Side-to-Side registration...
Page 576
B230/B237/D042 5-188 SM 007 ADF: Right 008 ADF: Left [Scanner Free Run] 4013 Performs the scanner free run with the ex posure lamp on or off in the following mode. Full color mode / Full Size / A3 or DLT 001 Lamp: ON 002 Lamp: OFF [Scan] 4014 Execute the scanner free fun with each mode. 001 HP Detection Enable - Scanner free run with HP sensor check. 002 HP Detection Disable - Scanner free run without HP sensor check. 4020 [Dust Check] 001 Detection: ON/OFF *ENG...
Page 577
SM 5-189 B230/B237/D042 Service Tables 1: Weakest 2: Weak 3: Strong 4: Strongest [APS Operation Check] 4301 Displays a code that represents the orig inal size detected by the original sensors. (See Input Check Table.) 001 APS Operation Check - - [APS Min Size (A5/HLT/16K)] 4303 Specifies the result of t he detection when the outputs fr om the original sensors are all OFF. 001 APS Min. Size (A5/HLT/16K) *ENG[0 to 2 / 0 / 1 /step] 0: No Original 1: A5-Lengthwise (16K SEF...
Page 578
B230/B237/D042 5-190 SM Set the Mask for Original. These SPs set the area to be masked during platen (book) mode scanning. 001 Book: Leading Edge 002 Book: Trailing Edge 003 Book: Left 004 Book: Right 005 ADF: Leading Edge 007 ADF: Right 008 ADF: Left [0 to 3.0 / 0 / 0.1 mm/step] [IPU Test Pattern] 4417 Selects the BICU test pattern. 001 Test Pattern Selection [0 to 24 / 0 / 1/step ] 0: Scanned image 1: Gradation main scan A 2: Gradation main scan B 3: Gradation main scan...
Page 579
SM 5-191 B230/B237/D042 Service Tables 001 - *ENG[32 to 255 / 128 / 1 /step] 255: Strongest density [Saturation Adjustment] 4440 Adjusts the level of saturation for copying. 001 Saturation Adj. 1 *ENG [0 to 5 / 3 / 1 /step] 0: High 1: Lowest 2: Lower 3: Default 4: Higher 5: Highest 4450 [Scan Image Pass Selection] Black Subtraction ON/OFF [0 or 1 / 1 / - ] 0: OFF, 1: ON 001 Uses or does not use the black reduction image path. SH ON/OFF [0 or 1 / 0 / 1 /step] 0: ON, 1:...
Page 580
B230/B237/D042 5-192 SM 001 Copy: Bk: Text *ENG 002 Copy: M: Text *ENG 003 Copy: C: Text *ENG 004 Copy: Y: Text *ENG 005 Copy: Bk: Photo *ENG 006 Copy: M: Photo *ENG 007 Copy: C: Photo *ENG 008 Copy: Y: Photo *ENG [0 to 10 / 5 / 1 /step] 10: Darkest density [ACC Offset: Light] 4505 Adjusts the offset correction for light areas of the ACC pattern. 001 Self Machine: Bk *ENG 002 Self Machine: M *ENG 003 Self Machine: C *ENG 004 Self Machine: Y *ENG [-128 to 127 / 0 / 1 /step]...