Bit Switches SM 89 B786 B786 Fax Option IP Fax Switch 03 [SP No. 1-111-004] No. FUNCTION COMMENTS 0 Effective field limitation for G3 standard function information 0: OFF, 1: 4byte (DIS) Limits the effective field for standard G3 function information. 1 Switching between G3 standard and G3 non standard 0: Enable switching 1: G3 standard only Enables/disables switching between G3 standard and G3 non-standard. 2 Not used. Do not change this setting. 3 ECM frame size selection at...
Page 1062
Bit Switches B786 90 SM Bit 3 Bit 2 Bit 1 Bit 0 0 0 0 1 2400 bps 0 0 1 1 4800 bps 0 0 1 1 7200 bps 0 1 0 0 9600 bps 0 1 0 1 12.0 Kbps 0 1 1 0 14.4 Kbps 0 1 1 1 16.8 Kbps 1 0 0 0 19.2 Kbps 1 0 0 1 21.6 Kbps 1 0 1 0 24.0 Kbps 1 0 1 1 26.4 Kbps 1 1 0 0 28.8 Kbps 1 1 0 1 31.2 Kbps 1 1 1 0 33.6 Kbps 4-5 Modem setting for transmission Sets the modem for transmission. The default is 00 (V29). Bit 5: 0, Bit 4: 0 = V29 Bit 5: 0, Bit 4: 1 = V17 Bit 5: 1, Bit 4: 0 = V34*...
Page 1063
Bit Switches SM 91 B786 B786 Fax Option 0 1 0 1 12.0 Kbps 0 1 1 0 14.4 Kbps 0 1 1 1 16.8 Kbps 1 0 0 0 19.2 Kbps 1 0 0 1 21.6 Kbps 1 0 1 0 24.0 Kbps 1 0 1 1 26.4 Kbps 1 1 0 0 28.8 Kbps 1 1 0 1 31.2 Kbps 1 1 1 0 33.6 Kbps Modem setting for reception Sets the modem type for reception. The default is 0100 (V27ter, V29, V17). Bit 7 Bit 6 Bit 5 Bit 4 0 0 0 1 V27ter 0 0 1 0 V27ter, V29 0 0 1 1 V27ter, V29, V33 (invalid) 0 1 0 0 V27ter, V29, V17 0 1 0 1...
Page 1064
Bit Switches B786 92 SM 1: Hang up after transmitting DCN 4 Number of times for training 0: 1 time, 1: 2 times Selects the number of times training is done at the same bit rate. 5 Space CSI transmission setting at no CSI registration 0: Not transmitted, 1: Transmitted When 0 is selected, frame data is enabled. When 1 is selected, the transmitted data is all spaces. 6-7 Not used Do not change these settings. IP Fax Switch 08 [SP No. 1-111-009] No. FUNCTION COMMENTS 0-1 T1 timer...
Page 1065
NCU Parameters SM 93 B786 B786 Fax Option 4.4 NCU PARAMETERS The following tables give the RAM addresses and the parameter calculation units that the machine uses for ringing signal detection and automatic dialing. The factory settings for each country are also given. Most of these must be changed by RAM read/write (SP2- 102), but some can be changed using NCU Parameter programming (SP2-103, 104 and 105); if SP2-103, 104 and 105 can be used, this will be indicated in the Remarks column. The...
Page 1066
NCU Parameters B786 94 SM Address Function Spain 14 0E Czech 35 23 Israel 15 0F Poland 36 24 Address Function Unit Remarks 680501 Line current detection time 680502 Line current wait time 680503 Line current drop detect time 20 ms Line current detection is disabled. Line current is not detected if 680501 contains FF. 680504 PSTN dial tone frequency upper limit (high byte) 680505 PSTN dial tone frequency upper limit (low byte) Hz (BCD) If both addresses contain...
Page 1067
NCU Parameters SM 95 B786 B786 Fax Option Address Function Unit Remarks 680513 PSTN busy tone frequency upper limit (high byte) 680514 PSTN busy tone frequency upper limit (low byte) Hz (BCD) If both addresses contain FF(H), tone detection is disabled. 680515 PSTN busy tone frequency lower limit (high byte) 680516 PSTN busy tone frequency lower limit (low byte) Hz (BCD) If both addresses contain FF(H), tone detection is disabled. 680517 PABX dial tone frequency upper limit (high...
Page 1068
NCU Parameters B786 96 SM Address Function Unit Remarks 680527 PABX busy tone frequency upper limit (low byte) detection is disabled. 680528 PABX busy tone frequency lower limit (high byte) 680529 PABX busy tone frequency lower limit (low byte) Hz (BCD) If both addresses contain FF(H), tone detection is disabled. 68052A Busy tone ON time: range 1 68052B Busy tone OFF time: range 1 68052C Busy tone ON time: range 2 68052D Busy tone OFF time: range 2 68052E Busy tone ON time:...
Page 1069
NCU Parameters SM 97 B786 B786 Fax Option Address Function Unit Remarks 68053A International dial tone reset time (HIGH) 68053B International dial tone continuous tone time 68053C International dial tone permissible drop time Belgium: See Note 2. 68053D International dial wait interval (LOW) 68053E International dial wait interval (HIGH) - 68053F Country dial tone upper frequency limit (HIGH) 680540 Country dial tone upper frequency limit (LOW) If both addresses contain FF(H),...
Page 1070
NCU Parameters B786 98 SM Address Function Unit Remarks 68054D Time between final OHDI relay closure and DO relay opening or closing 1 ms See Notes 3, 6 and 8. SP2-103-015 (parameter 14). This parameter is only valid in Europe. 68054E Minimum pause between dialed digits (pulse dial mode) See Note 3 and 8. SP2- 103-016 (parameter 15). 68054F Time waited when a pause is entered at the operation panel 20 ms SP2-103-017 (parameter 16). See Note 3. 680550 DTMF tone on time...