    							6. INSTALLATION OF KEY SERVICE UNIT 
    6.1 PAD ADJUSTMENT AND EXPLANATION ON FUSES 
    f \/ NOTE: PLEASE TURN OFF POWER SWITCH WITH. 
    J 
    OUT FAIL, BEFORE OPEN THE FRONT 
    COVER 
    1.1 HOW TO DETACH FRONT COVER 
    1 Push up the slide. 2 Open the cover and detach it from the main body. 
    CAUTION: TO AVOID ELECTRIC SHOCKS, NEVER OPEN THE INNER COVER. 
    Set to “OFF” position 
    9 
    NOTE 
    l Please use rated fuses only. 
    l When replaceing fuse F5 and F6, detach by 
    squeezing in the upper and lower surfaces of the 
    plastic cover. 
    1 
    . 
    3. EXPLANATION ON FUSES 
    Fl (IA) . . . AC Power Fuse 
    F5 (0.3A) 
    . . . Power Line Fuse for TELs 1 and 2 
    F6 (0.3A) 
    . Power Line Fuse for TELs 3 and 4. 
    Please note that the following fuses are installed in 
    the places beyond your access. 
    F2 (8A) 
    . . . . AC Power Fuse 
    F3 (2A) 
    . DC12V Power Fuse 
    F4 (IA) 
    . . . _ for Ni-Cd back up battery 
    * 
    / 
    NOTE: Please use rated fuses only.  
    						
    							. 
    6.2 CLAMPING OF INSTALLATION WIRING CABLES, AND INSTALLATION 
    BATTERY UNIT (V~-20864). AND CONNECTION OF BACKUP 
    7 NOTE: PLEASE TURN OFF POWER SWITCH WITH- 
    OUT FAIL, BEFORE INSTALLING THE BAT- 
    TERY UNIT. 
    J 
    1. CLAMPING OF INSTALLATION WIRING 
    CABLES 
    When performing the cable connections, pro- 
    vide enough extra cable for the key service 
    unit. This is necessary for future checks. 
    Push in the cables from the top of the cable 
    guide. 
    / 
    b 
    f2. CONNECTION OF BACKUP BATTERY UNIT 3 
    1 Please turn off power switch before installing 
    the battery unit. 
    2 Install the battery unit to the key service unit. 
    1 Effective operating time by backup battery 
    Part Number of Power 
    Failure Backup Battery Effective Operating Hours 
    VA-20864 Approx. 30 minutes 
    2 If there is a power failure of approximately 60 
    minutes or more, the battery will require 15 
    hours or so to recharge. 
    3 Replace the battery every 3 years or so. 
    4 Use a designated battery only. 
    - 
    10  
    						
    							7. INSTALLATION OF KEY TELEPHONE 
    . 
    7.1 VOLUME ADJUSTMENT 
    Incoming Ringing Tone Adjusting Volume 
    I MAX’ m-1 I+MlN 
    I 
    ADJUSTMENT OF SPKR VOLUME 
    SPKR Volume Adjusting Volume 
    m 
    MAX- [1111111-l I+MfN 
    7.2 HOW TO MOUNT THE KEY TELEPHONE ON THE 
    WALL 
    When modular jack for a wail phone is installed on 
    the wall, the key telephone can be mounted and used 
    on the wail. volume level is increased by approximately 6 dB. 
    1 RE-INSERTION OF HANDSET GUIDE 
    1 Pull out the handset 2 Reverse the direction of 
    guide in the arrow the handset guide and 
    The key telephone with a built-in speakerphone is 
    installed with an exclusive adaptor, for on the wall 
    installations. 
    2. REINSTALLATION OF THE LOWER CASE 
    I Remove and disconnect 2 Turn the lower case upside 3 Secure the lower case with 
    screws and a station cable. down. the screws. 
    12  
    						
    							6.3 HOW TO MOUNT THE KEY SERVICE UNIT ON THE WALL 
    (USE THE KEY SERVICE UNIT ONLY ON THE WALL,) 
    (1) Detach the case 
    cover of the key service unit. 
    Refer to 6.1.1. 
    (2) 
    Drill the wall according to the specified dimensions 
    and install wood screws (0.16 in. in diameter) to the 
    two places at the top. Leave each of the screw hea& 
    sticking out 6.6 
    in. or SO 
    (3) 
    1 
    Insert the mounting screw heads into the two upper 
    2 Pull down the rear case. 
    mounting holes on the case. 
    3 The screw heads will be visible at the front when the 
    rear case is pulled down,thentighten the screws com- 
    pletely. 
    (4) 
    install screws to the lower side. 
    - Screwdrivei  
    						
    							3 INSTALLATION ON THE WALL 
    1 Connect the output cord from within the modular jack for a wall phone to the key 
    service unit. 
    2 Using a short cord, connect the modular jack for a wall phone to the key telephone connector. 
    3 Mate the lower case hole to projection of modular jack for a wall phone.  
    						
    							8. WIRING CONNECTION OF EQUIPMENTS 
    8.1 CONNECTION OF KEY SERVICE UNIT AND KEY TELEPHONE 
    fyG--) 
    When usmg five key telephones or more, use Exten- 
    I sion EC unit. (See page 18) 
    II TEL CONNECTION TERMINAL 
    Make connections to TELs 1 through 4. 
    - I 11 )IIIIIIl!llII) 1 ( 31 COLl ANDCOL2  
    II II/ Connect the Central Office Line (COL) to modular 
    jack connector of COLl and COL2, respectively. 
    l For couolino of cable. either of followina A. B and C can be used. 
    and doorphone 
    unit is connected. bell is attached. 
    COUPLING  
    						
    							l CONNECTION EXAMPLE 
    . EXPLANATORY NOTES cl A MODULAR 
    MODULAR 
    CONNECTOR -CONNECTOR TERMINAL BOX 
    MODULAR 
    CONNECTOR - BCREW :h,.“i%~~A~%,BBrj too) 
    MODULAR 
    . MODULAR CONNECTOR 
    CONNECTOR 
    MODULAR TERMINAL BOX 
    25 FEET CONNECTOR 200 FEET 
    EY SERVICE UN11 
    TEL 5.6 KEY TEL 
    TEL 7.8 S.L. TEL 
    In case of using 
    extension EC unit 
    (VA-2084 1 I 
    -2 25 FEET OR LESS 
    200 FEET OR LESS 
    When VA-20841 is in usa, 
    Single Line Tel is connectable. 
    TEL 6 
    (Central office line) 200 FEET OR M( 
    I 22 AWG 
    I 24 AWG 
    I 26 AWG 
    I EXI  
    						
    							P F)at cable 
    I FEET OR MORE 
    ness of Quad Cable I Length of Quad Cable I 
    22 AWG 
    I 
    Within 1100 Feet 
    24AWG 
    26 AWG , 
    Within 700 Feet 
    Within 450 Feet 1 CONNECTION OF WIRING CABLE (FOR USE OF 
    MODULAR CONNECTOR) 
    l When the key service unit and TEL are within 25 feet, 
    use a privately used cable, 7 feet, 15 feet and 25 feet 
    cable are ready for use. 
    l Telephone line cord and Handset cord 
    Depending on connection method and length, 4 types 
    of Telephone line cord and 2 types of Handset cord 
    are available. 
    .TELEPHONE LINE CORD 
    When VA-20841 is in use, 
    Single Line Tel is connectable, 
    TEL 7 MODEL NO. 
    VAX-20880 
    VAX-20881 
    VAX-20882 
    VAX-20883 LENGTH 
    Short (wall-mount only) 
    7 feet 
    15 feet 
    25 feet 
    . HANDSET CORD 
    For a distanceof more than 200 feet. 
    Use a quad cable. 
    11 
    *When the key service unit and TELare within 25-200 
    feet range, the cable available from the market can 
    be used by connecting with a modular terminal 
    *For connecting, see the left hand column. 
    f, COUPLING OF QUAD CABLE  
    l When key service unit and TEL are apart more than 
    260 feet use a quad cable without fail. Quad cables 
    assure better characteristic than flat cables and so 
    they are also recommended for shorter distance 
    use. 
    *For 
    use of quad cable, use the connector for the 
    Screw-Modular. (Type B) 
     
    / 2 CONNECTING OF EXTENSION BELL (V&20863) 
    *Use a triforked modular terminal and connection as 
    shown in the figure. This connection is applicable to 
    TEL1 and TEL2. 
    l Operation of extension bell. 
    When the backup battery runs out, Extension bell 
    responds to COL receiving. 
    l COLl -+ TEL1 
    l COL2 --f TEL2 
    16  
    						
    							HOW TO USE CONNECTION TOOL 
    1 
    Cut a flat cable for a required length. 
    2 Peelcable sheath 
    the modular clipping tool, and pull and remove 
    the peeled cable sheath. At this time, leave the 
    colored sheath of the conductor as it is. 
    3 Put the modular terminal to the flat cable. 
    +e 
    4 Press and connect the terminal with B portion 
    of the modular clipping tool. 
    2 *For the modular terminal at the opposite side, 
    install the terminal in a reverse direction as shown 
    in the illustration. 
    RED 
    BLACK YELLOW YELLOW 
    . 
    HOW TO CONNECT THE QUAD CABLE 
    . 
    The quad cable marketed can not be connected to the modular connector. 
    l When using the quad cable terminal, use screw terminal. 
    . On one side, connect the quad cable wires to the terminals with 
    the same colour. 
    l On the other si  
    						
    							8.2 INSTALLATION AND CONNECTION OF EXTENSION EC UNIT 
    When using five key telephones or more, connect them using Extension EC Unit. The following types of Extension 
    EC Units are available. 
    A For extending 4 key telephones VA-20040 
    B For extending 2 key telephones and 2 SLTs VA-20841 (to be released shortly) 
    B _ 
    7 NOTE: PLEASE TURN OFF POWER SWITCH WITHOUT 
    FAIL, BEFORE INSTALLING THE EC UNIT 
    J 
    . 
    1 A. HOW TO INSTALL EC UNIT VA-20840 
    1. Put lower side of the EC unit to the rib. 2 Push down the other side of the EC unit and 
    fix it to the guide. 
    3 Insert the EC unit connector to connector CNl 
    of the main printed circuit board. 