71 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 4.2. Service Modes (For Facsimile) Caution: The factory default parameters are preset (country dependent) for optimum performance and in compliance with the local telecommunication regulations/standards, and do not need to be changed. Changing some of these parameters may cause the unit to be no longer compliant or become inoperable. 4.2.1. Fax Service Mode Procedure 1. To enter the Fax Service Mode a. Press “FUNCTION” and then “7” keys. b. Press “MONITOR” four times, then press “* (TONE)”. c. Enter the desired code number or press the “V”, ”/\” arrow keys. 2. To exit the Fax Service Mode Press “STOP” key. Note: The following buttons provide these functions in the Service Mode: 4.2.2. FAX Service Mode Table The following service modes are provided to assist you in setting operational functions of the unit and determining the condition of the unit.START: : The new setting value is stored in the machine. V” : Scroll the function parameter number down. / “ : Scroll the function parameter number up. No. Service Mode Description 00 Not Used 01 Function Parameter Setting Allows changes to the function parameters (the home position, etc.). 02 RAM Edit ModeFactory use only. 03 Print Parameter List / Report Prints the Function Parameter List, Page Memory Test, Printer Report, All Document File, Protocol Trace and Toner Order Form. 04 Modem Tests Generates various binary, tonal and DTMF signals, by the modem. 05 Not Used 06 RAM Initialize Initialize RAM and restore the default value of the function parameters. Note: Turn the Power Switch to the OFF and back to the ON position to enable the parameter settings. 07 Not Used 08 Check & Call Allows input of information for Service Alert Report, Maintenance Alert Report and Toner Order Form. 09 System Maintenance Used for Firmware Update, Firmware Backup, Parameter Restore, Parameter Backup, Transferring Firmware from the PC to the Flash Card and Sending a Received File during a fatal printer error. 10 Firmware Version Displays Firmware Version for SC, SC Boot, Panel, etc. Downloaded From ManualsPrinter.com Manuals
72 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 4.2.3. Fax Service Mode 1 (Function Parameter Setting) Use the following procedure to change the function parameters. Enter the desired code number and press “START” key. ↓ If you wish to select another code number, scroll the menu with the “V”, ”/\” arrow keys. ↓ Select the desired function code and press the START key. ↓ When the “CLEAR” key is pressed, the selected code input will not be accepted. ↓ Press “STOP” key, then press “FUNCTION” and “CLEAR” keys sequentially to exit the service mode. Function Parameter Table No. Parameter Selections Function 000 Monitor/Tel Dial 1 = Monitor 2 = Tel/DialSelects whether the machine starts to TX automatically during On-Hook dialing. Monitor: Start to TX after pressing START TEL/DIAL: Start to TX automatically 001 Alarm Status 1 = Off 2 = Timer 3 = ConstantSelects the No Paper or No Toner alarm status. OFF: Alarm is disabled. Timer: Alarm will shut off after 6 seconds. Constant: Alarm will not stop until STOP is pressed or the error is cleared/ corrected. 002 Stop Comm. JRNL1 = Off 2 = OnSelects whether the machine prompts to print the COMM. Journal when the printout condition is set to INC and STOP is pressed during communication. 003 Continuous Poll 1 = Off 2 = Stn (Tx only) 3 = Hub (Rx only)Selects whether the Continuous Polling feature is enabled. Stn: Place the document(s) on the ADF, then press the assigned One-Touch Key to store or add the documents into a polled file. (See Note 1) Hub: When the polling command is initiated, the machine will continuously poll originals from the remote stations until it is interrupted by pressing STOP. 004 Numeric ID Set 1 = Off (will not accept) 2 = On (accepts)Selects whether the machine accepts and allows to set or change the Numeric ID. Downloaded From ManualsPrinter.com Manuals
73 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 005Destination Code (UF-7100/8100 only)000 : Austria 001 : U.K. 002 : Canada 003 : Denmark 004 : Taiwan 005 : Finland 006 : Germany 007 : Netherlands 008 : Italy 009 : Spanish 010 : Hong Kong 011 : Australia 012 : Switzerland 013 : Norway 015 : Portuguese 016 : Ireland 017 : Belgium 018 : Sweden 019 : Turkey 020 : U.S.A. 021 : France 022 : New Zealand 025 : Japan 029 : Poland 030 : Czech 031 : Russia 032 : Greece 033 : Hungary 034 : Indonesia 035 : South Korea 038 : Malaysia 039 : China 045 : Thailand 048 : South Africa 049 : Singapore 050 : Universal 051 : East Euro 999 : InitializeSpecified destinations only. 006 ID Display 1 = Number (Numeric ID) 2 = Chara (Character ID)Selects the priority of displaying the ID. 007 JRNL Column 1 = Station 2 = RCV’D IDSelects the contents of the ID to display on the Journal. 008 Monitor 1 = Off 2 = OnSelects whether the Monitor is ON/OFF for monitoring fax signals. (FOR SERVICE USE ONLY) 009 DC Loop 1 = Off (Normal) 2 = On (Off Hook)Selects a false Off Hook state for back to back communication test. 010 TX Level 00 = 0 dBm ~ 15 = -15 dBmSelects the TX signal output level, 0 to -15 dBm in 1 dBm steps. Function Parameter Table No. Parameter Selections Function Downloaded From ManualsPrinter.com Manuals
74 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 011 RX Level 1 = -43 dBm 2 = -38 dBm 3 = -33 dBm 4 = -48 dBmSelects the receiving sensitivity of -33/-38/-43/-48 dBm. 012 DTMF Level 00 = 0 dBm ~ 15 = -15 dBmSelects the DTMF output level, 0 to -15 dBm in 1 dBm steps. 013 G3 RX EQL 1 = 0dB 2 = 4dB 3 = 8dB 4 = 12dBSelects the cable equalizer for G3 reception mode, 0dB, 4dB, 8dB or 12dB. 014 G3 TX EQL 1 = 0dB 2 = 4dB 3 = 8dB 4 = 12dBSelects the cable equalizer for G3 transmission mode, 0dB, 4dB, 8dB or 12dB. 015 ~ 016Not Used 017 TX Start 2400 bps 4800 bps 7200 bps 9600 bps TC7200 TC9600 12000 bps 14400 bpsSelects the transmission modem start speed, 14400/12000/TC9600/TC7200/9600/7200/4800/ 2400 bps. (Press “V” or “/ “ to select the symbol rate.) Note: This parameter is applicable only when communicating with regular G3 machines. When communicating with Super G3 (V.34) machines, use Parameter No. 32. 018 RX Start 2400 bps 4800 bps 7200 bps 9600 bps TC7200 TC9600 12000 bps 14400 bpsSelects the reception modem start speed, 14400/ 12000/TC9600/TC7200/9600/7200/4800/2400 bps. (Press “V” or “/ “ to select the symbol rate.) Note: This parameter is applicable only when communicating with regular G3 machines. When communicating with Super G3 (V.34) machines, use Parameter No. 33. 019 ITU-T V.34 1 = Off 2 = On 3 = SelectSelects whether the ITU-T V.34 is Off, On or Select. Select: Select whether the ITU-T V.34 is Off or On, when entering Phone Book Dialing Numbers or Manual Number Dialing. 020 ITU-T ECM 1 = Off (Invalid) 2 = On (Valid)Select the ECM mode. 021 EP Tone 1 = Off (without EP Tone) 2 = On (with EP Tone)Selects whether to add the echo protect tone on V.29 mode. (Used when Echo Suppression is disabled.) On: Add Off: Do not add 022 Signal Interval 1 = 100 ms 2 = 200 ms 3 = 500 msSelects the time interval between the receiving signal and the transmitting signal. 023 TCF Check 1 = Normal (Short) 2 = LongSelects the TCF check interval Long/Short 024 CED Frequency 1 = 1080 Hz (non ITU-T) 2 = 2100 HzSelects the CED frequency 2100/1080 Hz Function Parameter Table No. Parameter Selections Function Downloaded From ManualsPrinter.com Manuals
75 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 025 COMM. Start-Up 1 = First 2 = SecondSelects the communication start-up condition (XMT and Polling). (Used when Echo Suppression is disabled.) 026 Non-Standard 1 = Off (Invalid) 2 = On (Valid)Selects own mode (Panafax mode). 027 Short Protocol B 1 = Off (Invalid) 2 = On (Valid)Selects the short protocol mode. 028 Short Protocol D 1 = Off (Invalid) 2 = On (Valid)Selects the short protocol mode. When activated, it allows the machine to automatically store the modem speed for each Auto Dial Number. 029 Remote Diagnostics1 = Off (will not accept) 2 = On (accepts)Selects whether the machine accepts Remote Diagnostics from the service station. 030 CED & 300 bps 1 = 75 ms 2 = 1 secSelects the pause interval between the CED and the 300 bps signal. (Used when Echo Suppression is disabled.) 031 RTC = EOL x 12 1 = Off (EOLx6) 2 = On (EOLx12)Selects the RTC signal, EOLx6 or EOLx12. 032 V34 TX Start 2400-33600bps Selects the transmission modem start speed for V.34 communication, 33600-2400 bps. (Press “V” or “/ “ to select the symbol rate.) 033 V34 RX Start 2400-33600bps Selects the receiving modem start speed for V.34 communication, 33600-2400 bps. (Press “V” or “/ “ to select the symbol rate.) 034 V34 TX SR 2400-3429sr Selects the transmission symbol rate for V.34, 3429/ 3200/3000/2800/2400 sr. (Press “V” or “/ “ to select the symbol rate.) 035 V34 RX SR 2400-3429sr Selects receiving symbol rate for V.34, 3429/3200/ 3000/2800/2400 sr. (Press “V” or “/ “ to select the symbol rate.) 036 Not Used 037 Protocol Display 1 = Off (not displayed) 2 = On (displayed)Selects whether to display the modem speed during communication. (Press the Job Status Key to display) 038 Not Used 039 Flash Time 5 = 50 ms ~ 100 = 1000 msSelects the pause interval before activating the Flash key. 040 Flash Time (PSTN)5 = 50 ms ~ 100 = 1000 msSelects the pause interval before activating the Flash key. (For Germany, Austria and Czech) 041 Pause Time 1 = 1 sec. ~ 10 = 10 sec.Selects the pause interval from 1 sec. ~ 10 sec. for dialing through a switchboard or for international calls. 042 Not Used 043 Redial Interval 0 = no waiting ~ 15 = 15 minutesSelects the redial interval from 0 to 15 minutes in 1 minute steps. Function Parameter Table No. Parameter Selections Function Downloaded From ManualsPrinter.com Manuals
76 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 044 Redial Count 0 = no redial ~ 15 = 15 times 0 ~ 9 (For Australia Only)Selects the redial count from 0 to 15 times in 1 step intervals. Note: In order to comply with the TBR21 requirement for the EC destinations, do not select 15 times. 045 Ring Detect Count1 = 1 ring ~ 9 = 9 ringsSelects the ring detection count from 1 to 9 rings in 1 ring step intervals. 046 On-Hook Time 0 = 0 sec. ~ 90 = 90 sec.Selects the on-hook time between sequential communication calls in 1 second step intervals. 047 Response Wait Interval1 = 1 sec. ~ 90 = 90 sec. 20 ~ 150 sec. (For France Only)Selects the waiting interval for the response after completing the dialing. 048~ 049Not Used 050 Ring Detect Mode 1 = Normal 2 = RoughSelects the quality of ringer detection. Use if the line signal is out of regulation, set to Rough so that the unit may detect the ringing signals. 051 Not Used 052 Pulse Rate 1 = 10 pps 2 = 20 ppsSelects the dial pulse rate 10/20 pps. 053~ 054Not Used 055 Busy Tone Check 1 = Off 2 = OnSelects whether to detect the Busy Tone. 056 Dial Tone Check (Except for USA and Canada)1 = Off 2 = OnSelects whether to detect Dial Tone before dialing the telephone number. 057 DC Loop Check (Except for USA and Canada)1 = Off 2 = OnSelects whether the unit checks the DC Loop during communication. 058 Comm. JRNL + Image1 = Off (without image) 2 = On (with image)Selects whether the machine prints the COMM. Journal with image. 059 Not Used 060 Version Indicates the Host software version. 061 TX/RX/PRT/CPY TX:****** PRT:****** RX:****** CPY:******Displays the transmitted, received, total printed and copied document count. 062 Print Counter 1 = Off 2 = OnSelects whether to print in the Fax Parameter List, the counter information that is displayed in the Function Parameter No. 61. 063~ 067Not UsedFunction Parameter Table No. Parameter Selections Function Downloaded From ManualsPrinter.com Manuals
77 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 068 NYSE Fax Forward (USA and Canada Only)1 = Off 2 = OnSelects whether the machine will forward the incoming and outgoing faxes to a specified station. Note: Once this parameter is activated, Fax Forwarding via Fax Parameter 054 is automatically disabled, an Access Code of 0000 is automatically assigned and Fax Parameter 038 has a new setting added called NYSE. 069 NYSE Local Print (USA and Canada Only)1 = Inc 2 = On (Always)Selects the printing condition for the incoming faxes after FAX Forwarding. INC.: Prints only if FAX Forwarding fails. ON: Always prints. 070 Line Error 128 lines 256 lines 512 lines 1024 line 2048 lines Off (will not disconnect line)1. Selects the line disconnect condition during reception. If the number of line errors exceed this setting, the unit will disconnect the line. Press “V” or “/ “ to select the symbol rate. 2. Selects the transmit condition of RTP/PIP or RTN/PIN. (Available if No.73 Error Detect is set to LINES) (See Note 1) 071 Total Error 1 = 5% 2 = 10% 3 = 15% 4 = 20%Selects the transmit condition of RTP/PIP or RTN/ PIN. (Available if No.73 Error Detect is set to RATE.) (See Note 2) 072 Continuous Error 1 = Off (unlimited) 2 = 3 lines/STD 3 = 6 lines/STD 4 = 12 lines/STDSelects the continuous total error criteria of Off/3/6 or 12 lines in Standard mode. If continuous total error exceeds this setting, the unit will transmit RTN/PIN. (Available if No.73 Error Detect is set to RATE.) 073 Error Detect 1 = Lines 2 = RateSelects the error detect condition Lines/Rate. 074 RTN Receive 1 = Disconnect 2 = ContinueSelects whether to disconnect the phone line or continue when RTN is received. 075 Coding 1 = MH (MH only) 2 = MR (MH or MR) 3 = MMR (MH or MR or MMR) 4 = JBIGSelects the coding scheme. 076 Batch TX (USA and Canada Only)1 = Off 2 = OnSelects whether the batch transmission is available. 077 RX JAM Length 1 = Off (unlimited) 2 = 2 mSelects the maximum length of a received document that can be printed. 078~ 079Not Used 080 Doc Top Feed -99 ~ +99Adjusts the distance between the scanning sensor ON position and the scanning start position. 081 Doc End Feed -90 ~ +127Adjusts the distance between the scanning sensor OFF position and the scanning end position. Function Parameter Table No. Parameter Selections Function Downloaded From ManualsPrinter.com Manuals
78 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 082 JAM Length 1 = 1 m 2 = 2 mSelects the maximum length of the original that can be scanned. 083 Not Used 084 Line As No Paper 1 = Ring (ring) 2 = Busy (keep line busy)Selects whether to ring or send a busy tone to the remote station when the recording paper runs out or the unit cannot receive because of any trouble. 085~ 086Not Used 087 Darker Level 0 = Lightest Contrast ~ 15 = Darkest ContrastSelects the contrast level. 0← →15 Lightest← →Darkest 088 Normal Level 089 Lighter Level 090~ 091Not Used 092 Smoothing 1 = Off 2 = OnSelects whether the smoothing function is available. 093 ~ 094Not Used 095 Reduction Ratio (70-100) Selects Print Reduction Ratio(%). 096 ~ 109Not Used 110 MAC Address Indicates the MAC Address. 111 Not Used 112 Insert EMAIL TXT 1 = Off 2 = OnSelects whether the Text Template (email message) is programmable and added on all email sent in the message body above the top line of text. (Up to 40 characters Programmed in the User Parameters.) Note: After enabling this feature, aside from entering the text in the User Parameters, it also has to be activated in each Auto Dial Number before it will take effect. It does not work for Direct Dialed Numbers. 113 ~ 114 Not Used 115 Time Zone 1 = Scroll 2 = DirectSelects the setting method for Time Zone. Scroll: Allows using Scroll Keys to scroll through the Time Zone Table. Direct: Allows you to input the Time Zone directly, (*) key to be used as a switch between +/-. 116 Overwrite Warning1 = Yes 2 = NoSelects whether the Overwrite Warning is included on the Internet FAX Result Receipt when programming the Auto Dialer via email. 11 7 ~ 121Not Used 122 LDAP 1 = Off 2 = OnSelects whether to use the LDAP Server. Special characters used in the LDAP, may not be recognized and display incorrectly. Function Parameter Table No. Parameter Selections Function Downloaded From ManualsPrinter.com Manuals
79 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 Note 1: Continuous Polling (Station Mode) This feature allows you to Store or Add documents into a Polled file in memory. To enable the Continuous Polling feature set the Function Parameter No. 003 to 2:STN (Station). Depending on the setting of the User Parameter (Facsimile) No. 119: QWERTY KEYBOAD, one of the following operations is available:. 1. One-Touch The upper 40 (40↑) Key is reserved for Store 4 Polling function, and cannot be changed. To prepare document(s) to be polled, simply place the document(s) on the ADF, then press the - (40) Key on the Keyboard (40↑ = LOWER Indicator turned OFF) to Store or Add document(s) into a Polled file. 2.Quick Name Search Press S (13) Key to search the Store 4 Polling name instead. To prepare document(s) to be polled, simply place the document(s) on the ADF and press the S (13) Key to search for Store 4 Polling, then press START Key to Store or Add document(s) into a Polled file. (Note: If a regular polled file is stored in memory, the Program Key for Continuous Polling will not be accepted.) Note 2: Function Parameter No. 070 (Line Error)-Transmit condition of RTP/PIP or RTN/PIN Note 3: Function Parameter No. 071 (Total Error)-Transmit condition of RTP/PIP or RTN/PIN 123 One Ring Sound (USA and Canada Only)1 = Off 2 = OnWhen Function Parameter No. 45 Ring Detect Count is set to 1 Ring, and this parameter is enabled (On), the machine will only ring once out loud, answering on the second ring count. 124 ~ 199Not Used 200 ~ 299- See Note 5 SignalSetting 1:128 2:256 3:512 4:1024 5:2048 6:Off MCF/PIP 0-31 0-63 0-127 0-255 0-511 Always RTP/PIP 32-63 64-127 128-255 256-511 512-1023 - RTN/PIN 64-127 128-255 256-511 512-1023 1024-2047 - SignalSetting 1:5% 2:10% 3:15% 4:20% MCF/PIP 0-2 0-4 0-7 0-9 RTP/PIP 3-4 5-9 8-14 10-19 RTN/PIN 5- 10- 15- 20-Function Parameter Table No. Parameter Selections Function Downloaded From ManualsPrinter.com Manuals
80 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 Note 4: The default setting of parameters depends on the country’s specifications or regulations. Print the Function Parameter List to confirm the default settings. Note 5: 200 Series Function Parameters Only appear when the G3 Communications Port Kit is installed and follow the same numbering order. Downloaded From ManualsPrinter.com Manuals