Installation/Troubleshooting [For assistance, please call: 1-800-272-7033] 61 Troubleshooting 2.6 Audio Problems ProblemCause and Remedy Listen button is displayed gray.The [Input] setting is set to [Disable] on the Audio page. Change it to [Enable]. (See page 75 of the Operating Instructions on the Setup CD-ROM) In the access level settings on the General User page, [Listen] is not permitted. Permit [Listen]. (See page 81 of the Operating Instructions on the Setup CD-ROM) Talk button is displayed gray.The [Output] setting is set to [Disable] on the Audio page. Change it to [Enable]. (See page 75 of the Operating Instructions on the Setup CD-ROM) In the access level settings on the General User page, [Talk] is not permitted. Permit [Talk]. (See page 81 of the Operating Instructions on the Setup CD-ROM) When accessing a camera on a LAN, the web browser settings are going through a proxy server. Change the settings so that they do not go through a proxy server. (see page 146 of Operating Instructions on the Setup CD-ROM) Neither Listen nor Talk button can be used.When accessing a camera on a LAN, the web browser settings are going through a proxy server. Change the settings so that they do not go through a proxy server. (see page 146 of Operating Instructions on the Setup CD-ROM)
Installation/Troubleshooting 62 Troubleshooting Audio cannot be heard on the computer.The Listen button appears like this: Click the Listen button. (It will change to .) Listen button is displayed gray. [Listen] is not permitted on the General User page. Permit it. (see page 81 of Operating Instructions on the Setup CD- ROM) The volume is set to minimum. Adjust the volume on the volume adjustment toolbar. The computer volume is set to mute or minimum volume. Open the PCs Volume Control window, and clear the output master and Wave/MP3s Mute checkbox, then adjust the volume. The Audio Control Bar is not displayed.The Audio Control Bar is not displayed when the number of simultaneous accesses exceeds the maximum number. Wait for a while, and access the camera again. Both the [Output] or [Input] settings are set to [Disable] on the Audio page. Change them to [Enable]. (See page 75 of the Operating Instructions on the Setup CD-ROM) In the access level settings on the General User page, both [Listen] and [Talk] are not permitted. Permit both [Listen] and [Talk]. (See page 81 of the Operating Instructions on the Setup CD-ROM) Problem Cause and Remedy
Installation/Troubleshooting [For assistance, please call: 1-800-272-7033] 63 Troubleshooting Audio is not produced from an external speaker connected to the camera.The Talk button appears like this: Click the Talk button. (It will change to .) The Talk button is gray. [Talk] is not permitted on the General User page. Permit it (see page 81 of Operating Instructions on the Setup CD- ROM). Microphone is not selected on your PCs volume control screen. Click [Options][Properties], and check [Recording] on the Volume Control window. In the Show the following volume controls column, check [Microphone], and click [OK]. Check [Select] on the Recording Control window. The PCs microphone input setting is set to mute. Open the PCs Volume Control window, check the microphone checkbox and then adjust the volume controls. A speaker is not connected to the camera. The cameras audio output terminal is a line output. Connect it to an external speaker with a built-in amplifier (see page 30 of Operating Instructions on the Setup CD-ROM). Audio can only be received for short periods of time. Change the settings to extend the PC Audio Input Timeout (see page 75 of Operating Instructions on the Setup CD- ROM). The camera speaker volume settings are set to minimum. Adjust the volume settings to an appropriate volume. The camera access is going through a proxy server. The audio feature cannot be used when going through a proxy server. Problem Cause and Remedy
Installation/Troubleshooting 64 Troubleshooting Noise can be heard.The plug of the external microphone or speaker is dirty. Wipe the connection terminal of the microphone or speaker. The external microphone or speaker is not connected properly. Correctly connect the external microphone or speaker. The audio from your PC speaker is being caught by your PC microphone, then the camera is transmitting the audio as the noise. Check [mute] for the microphone column on the volume control screen. Then the PC will stop transmitting audio to the camera. Audio is interrupted.Other applications are being run on the computer. Close other applications on your computer. The max. bandwidth is set to [Unlimited] on the Network page. Reduce the max. bandwidth (see page 45 or page 50 of Operating Instructions on the Setup CD-ROM). The mute for pan/tilt is set to [Enable] on the Audio page. This is not a problem. The input from the external microphone or speaker is small. When the audio is interrupted in listening, change sensitiveness to [Maximum] on the Audio page. When the audio is interrupted in talking, adjust the microphone volume on the PCs Volume Control window. Problem Cause and Remedy
Installation/Troubleshooting [For assistance, please call: 1-800-272-7033] 65 Troubleshooting 2.7 Image Buffer/Image Transfer ProblemCause and Remedy The camera does not transfer the image by E-mail or FTP.Errors have occurred on the way to the E-mail or FTP server. See the Protocol column on the Status page (see page 118 of the Operating Instructions on the Setup CD-ROM), and check if the error is displayed. The default gateway and DNS server addresses are not assigned correctly. Assign them correctly (see page 42 of the Operating Instructions on the Setup CD-ROM). Login ID and password for E-mail or FTP are invalid. Make sure that you enter your correct login ID and password. The camera does not transfer the image to a cell phone.The image quality is not set to [Mobile Phone] on the Image Buffer/Transfer page. Set the resolution to [160 x 120] and the image quality to [Mobile Phone]. Some cell phones do not support 320 x 240 resolution. The image is slowed down on the Buffered Image page. Or the camera transfers the old image.The transfer interval is too short. Set the transfer interval longer than the current setting (see page 93 or page 103 of the Operating Instructions on the Setup CD-ROM).
Installation/Troubleshooting 66 Troubleshooting 2.8 SD Memory Recording 2.9 IPv6 ProblemCause and Remedy Cannot write onto the SD memory card.It is writing protected. Cancel the writing protection. It takes time to record.Sometimes it takes time when it is formatted on a PC. Format it on the camera (see page 89 of Operating Instructions on the Setup CD-ROM). ProblemCause and Remedy The Top page is not displayed with the IPv6 address.The IPv6 address is not set on the camera. Check if the IP address and default gateway are displayed in the network (IPv6) column of the status page (see page 118 of Operating Instructions on the Setup CD-ROM). If neither or only one is displayed, it is possible that the connection is incorrect or that the IPv6 router is not set properly. Set them correctly. The IPv6 has not been set up on your PC. IPv6 is not set up in Windows XP when purchased. Change the settings to enable it. (see page 16 of Operating Instructions on the Setup CD-ROM) Router filtering is enabled. Permit camera access from the WAN side in router settings. Your network or ISP may not support IPv6 at this time.
Installation/Troubleshooting [For assistance, please call: 1-800-272-7033] 67 Troubleshooting 2.10 IPsec ProblemCause and Remedy The camera cannot be accessed in transport mode.IPsec policy settings are restricted. Decrease the number of computers connected simultaneously, and wait for a while, or shorten the lifetime in the PCs IPsec settings. IPsec settings have not been set on your PC. Set IPsec settings on your PC. See the Panasonic Network Camera support website ( http://panasonic.net/pcc/ipcam/) for how to do this. The pre-shared key is not set correctly. Set the same pre-shared key for the camera and your PC (see page 54 of Operating Instructions on the Setup CD- ROM). On the VPN router within the network, tunnel mode has been set. Transport mode and tunnel mode can not be used at the same time. Cancel the PCs IPsec settings, and communicate using tunnel mode. Either PCs SA*1 or Cameras SA is not established. *1SA (Security Association) refers to establishing a secure connection for an encrypted communication that uses IPsec or IPv6 by exchanging and sharing information such as the encryption scheme and key before communicating, or refers to an established virtual encrypted communication pathway. Disable the PCs IPsec settings, and enable it again.
Installation/Troubleshooting 68 Troubleshooting ProblemCause and Remedy The camera cannot be accessed in tunnel mode.The pre-shared key is not set correctly. Set the same pre-shared key for the camera and the VPN router (see page 57 of Operating Instructions on the Setup CD-ROM). The VPN router is not set correctly. Set the IKE and IPsec policy on the VPN router correctly (see page 57 of Operating Instructions on the Setup CD-ROM). Either VPN routers SA or cameras SA is not established. Restart the VPN router and the camera. E-mail or FTP transfer cannot be sent in transport mode.The network settings are not set correctly. Cancel the IPsec settings on the server, PC and camera, and check that the camera images can be transferred. If they can be transferred, the IPsec settings were not set correctly. Set them correctly (see page 54 of Operating Instructions on the Setup CD-ROM). The pre-shared key is not set correctly. Set the same pre-shared key for the camera, and server (see page 54 of Operating Instructions on the Setup CD-ROM). There is a e-mail server or FTP server within the tunnel mode network. Transport mode and tunnel mode cannot be used at the same time. Cancel the e-mail server or FTP servers IPsec settings, and communicate using tunnel mode. Either servers SA or cameras SA is not established. Restart the camera.
Installation/Troubleshooting [For assistance, please call: 1-800-272-7033] 69 Troubleshooting 2.11 Miscellaneous ProblemCause and Remedy ActiveX cannot be installed.Security software disables the ActiveX installation. Close the security software, and install the ActiveX again. The firmware is not updated.The firmware updating is not completed due to power off, network failure or other causes. Update the firmware again following the next procedures. *1See page 120 of the Operating Instructions on the Setup CD- ROM about updating firmware. Shortcut icon is not displayed in the My Network Places folder.UPnPTM Windows component is not installed in Windows XP or Windows Me. Install UPnPTM Windows component in Windows XP or Windows Me (see page 149 of the Operating Instructions on the Setup CD-ROM). No YesNo Yes Disconnect the plug of the AC cord of the camera from the outlet, and reconnect it again. Enter the IP address on the web browser to access the camera. Is the Top page displayed? Is the version updated? Access the Setup page and click [Status]. Check the firmware version on the Status page. Update the firmware*1. The firmware update is completed.
Installation/Troubleshooting 70 ProblemCause and Remedy Settings failed.You took 30 minutes or longer to save your settings on a [Setup] page. For added security, the time from opening to saving the [Setup] pages is limited to about 30 minutes. Save your settings within 30 minutes. You opened other [Setup] pages several times while setting a [Setup] page. Do not open other [Setup] pages several times while performing settings. You clicked your web browser’s back button while setting a [Setup] page. Do not use your web browser’s back button while setting a [Setup] page . You double-clicked [Save] on a [Setup] page. Do not double-click [Save] on a [Setup] page. You cannot solve problems.Call our customer call center at 1-800-272-7033.