Home > Panasonic > Video Recorder > Panasonic Multi Format Digital Hd Video Cassette Recorder Ajhd3700b 1 Operating Instructions

Panasonic Multi Format Digital Hd Video Cassette Recorder Ajhd3700b 1 Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Multi Format Digital Hd Video Cassette Recorder Ajhd3700b 1 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							– 151–
    TEST menu
    This menu is displayed when the  key is pressed.TEST
    F13
    F12
    F11
    F10
    F9
    F8 F7 F6 F5 F4 F3 F2 F1
    UDC  BOARD  INSTALLED
    Key
    F1
    F2
    F3
    F4
    F5
    F6
    F7
    F8–F12
    F13
    Key designation
    ——
    RF
    AUDIO
    MECHA
    SYSTEM
    FRONT
    SERVO
    ——
    IC CARD
    Description
    Transfers the VTR to the RF TEST menu screen.
    Transfers the VTR to the AUDIO TEST menu screen.
    Transfers the VTR to the MECHA TEST menu screen.
    Transfers the VTR to the SYSTEM TEST menu screen.
    Transfers the VTR to the TEST FRONT menu screen.
    Transfers the VTR to the SERVO TEST menu screen.
    Transfers the VTR to the TEST IC CARD menu screen. 
    						
    							– 152–
    TEST menu
    ∑OPERATION TIME display
    How long the VTR has been used for appears on this display.
    OPERATION:Total power-on time
    HEAD ROTATION:Cumulative head drum rotation time
    TAPE TRAVEL:Cumulative tape travel time
    THREADING:Total number of loading/unloading repeti-
    tions
    POWER ON:Number of times power has been turned on
    ∑SOFTWARE VERSION
    The software versions appear on this display.
    FRONT:Front software
    SYSCON:System control software
    AV:AV control software
    SERVO:Servo software
    ∑Serial number display
    The VTR’s serial number appears here.
    SERIAL NO:
    ∑UDC board display
    The UDC board installed in the VTR appears here.
    UDC BOARD INSTALLED
    OPERATION TIME
      OPERATION   :   1515 HOURS HEAD ROTATION :    370 HOURS
      TAPE TRAVEL :    225 HOURS THREADING     :   3870 TIMES
      POWER ON    :   9043 TIMES
    SOFTWARE VERSION
      FRONT  : FP-0.04.F   AV    : M1-0.13.O
      SYSCON : M1-0.13.M   SERVO : M1-0.13.- 
    						
    							– 153–
    RF TEST menu
    This menu is displayed by pressing the following keys:>F2TEST
    F13
    F12
    F11
    F10
    F9
    F8 F7 F6 F5 F4 F3 F2 F1 
    						
    							– 154–
    RF TEST menu
    Key
    F1
    F2
    F3
    F4
    F5
    F6
    F7
    F8
    F9–F10
    F11
    F12
    F13
    Key designation
    EECC SMPL
    Change of error rate
    measurement time.
    METER
    Switch of meter display.
    ——
    LOAD
    Load of default value.
    ——
    MODE
    CH
    EXIT
    ——
    ADJ RF
    RF adjustment value
    display.
    ——
    HEAD CLN
    Manual head cleaning.
    Description
    FAST:Measurement interval is 20 fields.
    SLOW
    :Measurement interval is 2 seconds.
    ERROR:Displays inner error level.
    ENV:Displays envelop level.
    All RF adjustment values return to factory settings.
    (Executes when pressed together with F key.)
    For selecting waveform monitor (WFM) output.°
    EYE:Outputs eye pattern.
    ENV
    :Outputs envelop.
    CONFI:Outputs CONFI CTL.
    R/P:Outputs R/P CTL.
    TC:Outputs TC waveform.
    For selecting EYE/ENV channel.°
    CH0
    :Selects EYE or ENV of CH0.
    CH1:Selects EYE or ENV of CH1.
    CH2:Selects EYE or ENV of CH2.
    CH3:Selects EYE or ENV of CH3
    Returns the VTR to the TEST menu screen.
    RF adjustment value is displayed and F6, F7, F11 and F12
    functions change to RF adjustment value display mode.
    Refer to “RF adjustment value display menu” (page 156).
    While this key is pressed, head cleaning takes place.
    (Head cleaning lasts for a maximum of only 20 seconds.)
    Operation
    1. Set VTR to PLAY mode.
    2. Press the F13 (HEAD CLN) key.
    Head cleaning functions during PLAY, JOG or VAR mode.
    °When the RF adjustment value display mode has been entered by F11, the WFM selection made immediately
    beforehand is held. 
    						
    							– 155–
    RF TEST menu
    ∑Error rate display
    The error rates (error occurrence rates) are indicated on the 1) TOTAL ERROR and 2) INNER ERROR 
    displays.
    1) TOTAL ERROR
    During recording, the error rate of the simultaneous playback
    signals is displayed. During playback, the error rate of the play-
    back signals is displayed. The audio channels are switched
    using the center cursor key.
    2) INNER ERROR
    The error rates after the inner errors have been corrected are
    displayed for the 8 heads.
    Proceed as follows to switch between VIDEO & AUDIO and
    AUDIO.
    1. Press the center cursor key to display the cursor.
    2. Press the F key and cursor key (2or 1) together to move
    the cursor to INNER ERROR.
    3. Press the center cursor key to select VIDEO & AUDIO or
    AUDIO.
    4. Press the ENT key to enter the selection.
    ∑Correction and revision statuses
    ≥Press the F key and cursor key together to move the highlighted portion from the error rate display 
    described above.
    ≥By aligning the cursor with CONCEAL V or A, with OUTER V or A, or with INNER and then pressing the 
    center cursor key, it is possible to switch between ON and OFF.
    ≥These settings are forcibly set to ON when the test menu is exited. Do NOT turn them OFF since doing so
    will cause noise to be generated in the playback picture and sound.
    TOTAL ERROR
    VIDEOAAUDIO
    OUTERCH1INNER ERROR
    VIDEO & AUDIO
    5
    4
    3
    2
    15
    4
    3
    2
    15
    4
    3
    2
    1
    BABABA
    CH0CH1CH2CH3B 
    						
    							– 156–
    RF adjustment value display menu
    F13
    F12
    F11
    F10
    F9
    F8 F7 F6 F5 F4 F3 F2 F1
    Key
    F1–F5
    F6
    F7
    F8–F10
    F11
    F12
    Key designation
    ——
    ADJ MODE
    Adjust mode.
    ADJ CH
    ——
    ADJ RF
    RF adjustment value
    display.
    ADJ SEL
    Description
    FIX:Holds the current adjusted value. Parameter can be
    readjusted by remote adjustment but the value cannot be
    changed with this unit.
    Selects the channel for display.
    EQ/REC/PLL:CH0, CH1, CH2, CH3
    When the F11 key is pressed, ADJ SEL is displayed at the F12
    key and the current adjusted value of the selected parameter is
    displayed. Selects adjustment mode with F6 key and channel
    with F7 key.
    This is used to display the selected RF adjusted value.
    EQ
    :The adjusted value of the playback equalizer is displayed.
    REC:The recording adjusted value is displayed.
    PLL:The PLL relative speed adjusted value is displayed.
    Pressing the F12 key enables switching by a toggling action in
    the following sequence:¢¢¢¢EQ>¢¢¢¢PLL>¢¢¢¢REC
    >¢¢¢¢EQ>and so on.
    Pressing the F key and F12 key together enables switching by a
    toggling action in the following sequence: 6014¢¢>6018¢¢>
    501¢¢>24P¢¢>625¢¢>D3¢¢>6014¢¢and so on.
    The RF system adjusted values for each format are displayed as
    these adjusted values. (They are used by the servicing
    engineer.) 
    						
    							– 157–
    AUDIO TEST menu
    This menu is displayed by pressing the following keys:>F3TEST
    F13
    F12
    F11
    F10
    F9
    F8 F7 F6 F5 F4 F3 F2 F1
    Key
    F1
    F2
    F3
    F4
    F5
    F6
    F7
    F8
    F9
    F10
    F11
    F12
    F13
    Key designation
    CH-1
    CH-2
    CH-3
    CH-4
    CUE
    MONI.L
    MONI.R
    EXIT
    REF.LEV
    IMPED.
    ——
    OUT LEV.
    IN LEV.
    Description
    Sets the CH1 analog input/output reference level.
    Sets the CH2 analog input/output reference level.
    Sets the CH3 analog input/output reference level.
    Sets the CH4 analog input/output reference level.
    Sets the CUE input/output reference level.
    Sets the monitor L channel output reference level.
    Sets the monitor R channel output reference level.
    Returns the VTR to the TEST menu screen.
    Sets the PCM audio reference level. (This can be done only in
    the servicing engineer mode.
    ≥When the F9 and F keys are pressed together, the reference
    level (Fs) toggles between j18 dB and j20 dB.
    Sets the input impedance. (This can be done only in the
    servicing engineer mode.)
    ≥When the F10 and F keys are pressed together, the input
    impedance is toggled between 600 ohms and HIGH.
    Sets the analog output reference level.
    ≥When the F12, BS and F keys are pressed together, the names
    of the F1 to F7 menus are displayed, and switching between
    them is acknowledged.
    Sets the analog input reference level.
    ≥When the F12, BS and F keys are pressed together, the names
    of the F1 to F5 menus are displayed, and switching between
    them is acknowledged. 
    						
    							– 158–
    MECHA TEST menu
    This menu is displayed by pressing the following keys:>F4TEST
    F13
    F12
    F11
    F10
    F9
    F8 F7 F6 F5 F4 F3 F2 F1
    F13
    F12
    F11
    F10
    F9
    F8 F7 F6 F5 F4 F3 F2 F1
    The menu below is displayed when the  key is pressed.F5 
    						
    							– 159–
    Key
    F1
    F2
    F3
    F4
    F5
    F6–F7
    F8
    F9–F13
    Key designation
    MODE
    Loading without tape.
    ——
    C.SIZE
    Cassette size selection.
    ——
    SENSOR
    Sensor operation check.
    ——
    EXIT
    ——
    Description
    NORMAL
    :Normal operation.
    NO-TAPE:Loading without cassette tape is possible. Loading
    starts when the STOP button is pressed. Cassette is
    selected with F3 key. To abort operation, press the
    EJECT button. 
    Selects the size of the pseudo cassette when [NO TAPE] has
    been selected with F1 key. Large, medium or small cassette size
    can be selected.
    When this key is pressed for highlighting, the sensor frame is
    shown on the menu. Operation of each peripheral sensor of
    cylinder, reel base and front loading is checked. This key is
    especially for checks by service personnel.
    Press the F8 (EXIT) key to restore the original frame. 
    Returns the VTR to the TEST menu screen.
    MECHA TEST men 
    						
    							– 160 –
    SYSTEM TEST menu
    This menu is displayed by pressing the following keys:#.
    This menu contains keys for adjustments by service personnel. General users cannot operate these keys.
    Press F8 key to return to TEST menu.F5TEST
    Key
    F1 – F7
    F8
    F9 – F13
    Key designation
    ——
    EXIT
    ——
    Description
    Returns the VTR to the TEST menu screen.
    F13
    F12
    F11
    F10
    F9
    F8 F7 F6 F5 F4 F3 F2 F1 
    						
    All Panasonic manuals Comments (0)