PAN/TILT ItemTransmission Command
(ASCII)Response (ASCII) Parameter (ASCII)CMD:CmmPTccxxyy — mm=Monitor No.
cc=Camera No. 
• Panning speed
xx=00  STOP
xx=01 to 40(HEX) + direction panning
(Max is 40 and min is 01)
xx=81 to C0(HEX) - direction panning
(Max is C0 and min is 81)
• Tilting speed
yy=00  STOP
yy=01 to 40(HEX) + direction tilting 
(Max is 40 and min is 01)
yy=81 to C0(HEX) - direction tilting
(Max is C0 and min is 81)
Camera Control
CMD:CmmZMccn Zoom — mm=Monitor No.
cc=Camera No. 
n=0...

Page 152

156 156
AUX2 CMD:CmmA2ccn —mm=Monitor No.
cc=Camera No.
n=0 OFF
n=1 ON AUX1 CMD:CmmA1ccn —mm=Monitor No.
cc=Camera No.
n=0 OFF
n=1 ON
mm=Monitor No.
cc=Camera No.
n=0 OFF (Color)
n=1 ON (BW)
mm=Monitor No.
cc=Camera No.
n=0 STOP
n=1 PLAY
n=2 LEARN
mm=Monitor No.
cc=Camera No.
nnn=Camera function No. (001 to 256) ItemTransmission Command
(ASCII)Response (ASCII) Parameter (ASCII)
Cameras SETUP MENU  CMD:CmmCMccn — mm=Monitor No.
cc=Camera No.
n=0 OFF
n=1 ON
The following commands are available in
SETUP...

Page 153

157157
Transmission command toggles zoom.
mm=Monitor No.
n=0  Zoom OFF
n=1 + mark display ON*
n=2  Two-fold zoom
n=4  x4Live image/Playback image
n=8  x8Live image/Playback image
*Available only with the Multiplexer board CMD:RmmZM Multiscreen segment switch-
ing
Recorder Control
ItemTransmission Command
(ASCII)Response (ASCII) Parameter (ASCII)
CMD:RmmML ANS:RmmML mm=Monitor No.
Electronic Zoom ANS:RmmZMn
Play CMD:RmmPL ANS:RmmPL mm=Monitor No.
Pause CMD:RmmPA ANS:RmmPA mm=Monitor No.
Stop CMD:RmmSPn...

Page 154

158
Available only with the Multiplexer board
Transmission command toggles still display
ON or OFF.
mm=Monitor No.
cc=Camera No.
(cc=00 when toggling multiscreen still ON or
OFF)
n=0 OFF
n=1 ON
mm=Monitor No. FF ItemTransmission Command
(ASCII)Response (ASCII) Parameter (ASCII)
CMD:RmmFF ANS:RmmFF
REW CMD:RmmRW ANS:RmmRW mm=Monitor No.
Forward field advance CMD:RmmFA ANS:RmmFA mm=Monitor No.
Backward field advance CMD:RmmRA ANS:RmmRA mm=Monitor No.
Record CMD:RmmRC ANS:RmmRC mm=Monitor No.
Index...

Page 155

159
Alarm historyItemTransmission Command
(ASCII)Response (ASCII) Parameter (ASCII)
Model  No QID qid:WJ-SX150A Matrix switchers model  No.
Software version QRV qrv:*.**
/*.**
/*.**
/*.**
/*.**
/*.**qrv:*.**=Unit firmware version
/*.**= Master unit’s Multiplexer-board
firmware version
/*.**= Slave 1 unit’s Multiplexer-board
firmware version
/*.**= Slave 2 unit’s Multiplexer-board
firmware version
/*.**= Slave 3 unit’s Multiplexer-board
firmware version
/*.**= Slave 4 unit’s Multiplexer-board
firmware...

Page 156

160
Alarm display–ALM:cc:a:yyyymmdd:hhmm
ss:ba=Event
0=ALARM
1=ACK
2=RESET
yyyy=Year
mm=Month
dd=Day
hh=Hour
ss=Second
b=Daylight saving time
0=OFF
1=ON ItemTransmission Command
(ASCII)Response (ASCII) Parameter (ASCII)
Miscellaneous Control 

Page 157

161
■Error Code List
Error code(ASCII) Error type Meaning
ER000 No error There is no error.
ER001 No associated command There is no associated command.
ER002 Parameter invalid The parameters number, digit and range are invalid. 
ER003 Receiver buffers overflow The receiver buffer has reached overflow capacity.
ER301 Command invalid Invalid operation mode caused the command error.
ER302 Parameter invalid The parameters number, digit and range are valid, but the operation mode
is invalid.
ER303 Gateway...

Page 158

162
WORKSHEETS
Gathering information for the initial configuration and recording on the following worksheets are recommended. Then, if set-
tings need to be modified or updated later because of a change in surveillance needs or changes made in the systems com-
ponents, those worksheets can be used to track revisions to your system.
You should keep  all revised worksheets. Be sure to date them, in preparation for new entry or troubleshooting. Regardless of
the system size, the worksheets can track past,...

Page 159

163
■Checklist
It is recommended that the worksheets be completed in the following sequence:
Date completed: ___/ ___/ ___
●Master-Slave 
●Logical Camera Number 
Camera LCN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Master ON
Slave 1 ON/OFF
Slave 2 ON/OFF
Slave 3 ON/OFF
Slave 4 ON/OFF
Master and Slave 1
Camera Slave 1LCN
Master
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Normal connection (one unit only)
Master, Slave 1 and Slave 2
Camera Slave 1LCN
Slave 2Master
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16 

Page 160

164
Master and Slave 1 to 3
Camera Slave 1LCN
Slave 2Slave 3Master
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Master and Slave 1 to 4
Camera Slave 1LCN
Slave 2Slave 3 Slave 4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16 
Start reading Panasonic Matrix Switcher Wj Sx150a Operating Instructions

Related Manuals for Panasonic Matrix Switcher Wj Sx150a Operating Instructions

All Panasonic manuals