2.7 [1] Configuration
PC Programming Manual 61
Supported Card Types
2.7.2 [1-1] Slot—Summary
Summary information is displayed for all cards installed in the PBX.
Slot
Indicates the slot number (reference only).
Default
Current slot number
Value Range
Available slot numbers.
Maintenance Console Location
2.7.2 [1-1] Slot—Summary
Programming Manual References
NoneCard Maximum 
QuantitySupported Slot 
NumbersCard Programming
MPR: Main Processing Card 1 00 2.7.2 [1-1] Slot—Summary
HLC4: Pre-installed Hybrid...

Page 62

2.7 [1] Configuration
62 PC Programming Manual
Feature Manual References
None
Slot Type
Indicates the type of each slot (reference only).
Default
Not applicable.
Value Range
Fixed Slot: For initially installed 4 Hybrid ports
Free Slot Type A (02–04): For LCOT4/HLC4/PLC4 card
Free Slot Type B (05–06): For PLC8/SLC8 card
Option Slot (08–09): For MSG2/DPH4/ECHO8/EXT-CID/SVM2 card
Option Slot (10–11): For MSG2/ECHO8/EXT-CID/SVM2 card
Maintenance Console Location
2.7.2 [1-1] Slot—Summary
Installation Manual...

Page 63

2.7 [1] Configuration
PC Programming Manual 63
EXT-CID: Extension Caller ID Card
SVM2: 2-Channel Simplified Voice Message Card
MPR: MPR Card
Maintenance Console Location
2.7.2 [1-1] Slot—Summary
Programming Manual References
2.7.1 [1-1] Slot
2.7.3 [1-1] Slot—Extension Card Property
2.7.7 [1-1] Slot—LCO Card Property
2.7.10 [1-1] Slot—DPH Card Property
Feature Manual References
None
Status
Indicates the card status (reference only).
Note that MPR card status is always displayed as -.
Default
Slot 00: -...

Page 64

2.7 [1] Configuration
64 PC Programming Manual
SLT Pulse Dial Mode
Selects the type of pulse dial transmission appropriate to your area.
Default
Normal 
Value Range
Normal, Sweden, New Zealand
Maintenance Console Location
2.7.3 [1-1] Slot—Extension Card Property
Programming Manual References
None
Feature Manual References
None
SLT Off Hook Time
Specifies the minimum length that a pulse dial sent from an SLT must be for the PBX to recognize it 
as an off-hook signal.
Default
160 ms
Value Range
8 × n...

Page 65

2.7 [1] Configuration
PC Programming Manual 65
Value Range
8 × n (n=12–63) ms
Maintenance Console Location
2.7.3 [1-1] Slot—Extension Card Property
Programming Manual References
None
Feature Manual References
None
SLT Pulse Maximum Break Width
Specifies the maximum length of the break signal in a pulse dial.
Default
96 ms
Value Range
8 × n (n=9–20) ms
Maintenance Console Location
2.7.3 [1-1] Slot—Extension Card Property
Programming Manual References
None
Feature Manual References
None
SLT Pulse Minimum...

Page 66

2.7 [1] Configuration
66 PC Programming Manual
Feature Manual References
None
SLT Flash Detection
Enables the PBX to detect the flash signal sent when an SLT user presses the hookswitch or the 
Flash/Recall button.
Default
Enable
Value Range
Disable: The PBX disconnects the line to prevent placing the call on hold.
Enable: The PBX places the call on consultation hold.
Maintenance Console Location
2.7.3 [1-1] Slot—Extension Card Property
Programming Manual References
None
Feature Manual References
1.3.7...

Page 67

2.7 [1] Configuration
PC Programming Manual 67
Default
904 ms
Value Range
8 × n (n=3–191) ms
Maintenance Console Location
2.7.3 [1-1] Slot—Extension Card Property
Programming Manual References
None
Feature Manual References
None
DTMF-R STD Detection Time
Specifies the minimum length that a DTMF tone must be for the PBX to recognize it as a DTMF tone.
Default
30 ms
Value Range
2 × n (n=1–31) ms
Maintenance Console Location
2.7.3 [1-1] Slot—Extension Card Property
Programming Manual References
None
Feature...

Page 68

2.7 [1] Configuration
68 PC Programming Manual
Value Range
Slot number
Maintenance Console Location
2.7.4 [1-1] Slot—Extension Port
Programming Manual References
None
Feature Manual References
None
Por t
Indicates the port number (reference only).
Default
Current port number
Value Range
Port number
Maintenance Console Location
2.7.4 [1-1] Slot—Extension Port
Programming Manual References
None
Feature Manual References
1.5.7 Extension Port Configuration
Por t Type
Indicates the port type (reference...

Page 69

2.7 [1] Configuration
PC Programming Manual 69
Feature Manual References
1.5.7 Extension Port Configuration
Telephone Type
Indicates the connected telephone type (reference only).
The number of all connected telephones and Cell Stations can be viewed by clicking Por t Type View.
Default
Current connected telephone type
Value Range
APT: APT is connected.
DSS: DSS Console is connected.
VM: VPS is connected.
SLT: SLT is connected (or no telephone is connected to the Hybrid or SLT port).
CS: CS is...

Page 70

2.7 [1] Configuration
70 PC Programming Manual
Feature Manual References
None
Extension Number
Specifies the extension number of the port.
To change the extension number of a wired extension, follow the steps below:
1.Type the new extension number, then click Apply.
2.Set the status of the extension port to OUS, then INS.
When changing the extension number, make sure that the extension port is not in use. If the extension 
number is changed while the port is in use, the new extension number will not come...