Page 91
2.7 [1] Configuration PC Programming Manual 91 Feature Manual References None For Output (EIO)—Device Type Selects the type of connected output device (for output ports only). Default Door Opener Value Range Relay, Ringer, Door Opener Maintenance Console Location 2.7.10 [1-1] Slot—DPH Card Property Programming Manual References 2.11.6 [5-4] External Relay Feature Manual References 1.4.9 Door Open 1.5.8 External Relay For Sensor (EIO)—Input Signal Decision Time Specifies the minimum duration of continuous...
Page 92
2.7 [1] Configuration 92 PC Programming Manual Default 10 s Value Range 10 × n (n=1–255) s Maintenance Console Location 2.7.10 [1-1] Slot—DPH Card Property Programming Manual References None Feature Manual References 1.5.9 External Sensor 2.7.11 [1-1] Slot—DPH Port Command Commands for the DPH ports can be programmed. INS Puts the port in service. Default Not applicable. Value Range Not applicable. Maintenance Console Location 2.7.11 [1-1] Slot—DPH Port Command Programming Manual References 2.7.10 [1-1]...
Page 93
2.7 [1] Configuration PC Programming Manual 93 Value Range Not applicable. Maintenance Console Location 2.7.11 [1-1] Slot—DPH Port Command Programming Manual References 2.7.10 [1-1] Slot—DPH Card Property Feature Manual References None 2.7.12 [1-2] Portable Station Various portable station (PS) settings can be programmed. A maximum of 28 PSs can be registered. PS Registration and De-registration A PS must be registered to the PBX by programming both the PBX and PS before it can be used. Programming...
Page 94
2.7 [1] Configuration 94 PC Programming Manual 2.Highlight numbers and click the right arrow to select them for de-registration. Click Next. A dialog box will appear. 3.Click Confirm. If the de-registration is successful, the dialog box will show De-registration Succeed. If the de-registration is unsuccessful, the dialog box will show De-registration Error. De-registration will be terminated. 4.Click Close. If the PS is successfully de-registered, the status of the PS will update to show None....
Page 95
2.7 [1] Configuration PC Programming Manual 95 Feature Manual References 1.13.11 PS Connection Index Indicates the PS number (reference only). Default Not applicable. Value Range 1–28 Maintenance Console Location 2.7.12 [1-2] Portable Station Programming Manual References None Feature Manual References 1.13.11 PS Connection Extension No. Specifies the extension number of the PS. In Wireless XDP Parallel Mode, the PS can be used as a sub telephone with a wired main telephone (PT/SLT), and two of them...
Page 96
2.7 [1] Configuration 96 PC Programming Manual Extension Name Specifies the name of the PS. Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.7.12 [1-2] Portable Station Programming Manual References 2.10.8 [4-2-1] Portable Station—Extension Settings—Main—Extension Name Feature Manual References 1.13.11 PS Connection Status Indicates whether a certain PS is registered (reference only). Default None Value Range None, Registered Maintenance Console Location 2.7.12 [1-2]...
Page 97
2.7 [1] Configuration PC Programming Manual 97 automatically when a CS is connected to the PBX. Without the Radio System ID, PSs cannot be registered. System Wireless—System ID Indicates the radio system ID used to register a PS (reference only). Default Not stored. Value Range Not applicable. Maintenance Console Location 2.7.13 [1-3] Option Programming Manual References None Feature Manual References None New Card Installation—Card Status for any Card Selects the initial status of cards after...
Page 98
2.7 [1] Configuration 98 PC Programming Manual Value Range Disable, Enable Maintenance Console Location 2.7.13 [1-3] Option Programming Manual References None Feature Manual References None
Page 99
2.8 [2] System PC Programming Manual 99 2.8 [2] System 2.8.1 [2-1] Date & Time/Daylight Saving The date and time of the PBX, and Summer time (daylight saving time) can be programmed. Summer time sets the clock one hour forward at 2:00 AM on the start date, and one hour back at 2:00 AM on the end date. The start and end dates of a maximum of 20 different summer times can be programmed. To set the system date and time of the PBX, click 2.8.2 [2-1] Date & Time/Daylight Saving—Date & Time Setting....
Page 100
2.8 [2] System 100 PC Programming Manual Programming Manual References None Feature Manual References 1.1.7 Automatic Time Adjustment End Date—Year, Month, Day Specifies the end date of daylight savings time. Default Year: 2005 (For Daylight Saving Time number 1. The year advances by one for the subsequent Daylight Saving Times.) Month: 10 Day: Day of the last Sunday of the month Value Range Year: 2000–2099 Month: 1–12 Day: 1–31 Maintenance Console Location 2.8.1 [2-1] Date & Time/Daylight Saving...