Page 91

2.7 [1] Configuration
PC Programming Manual 91
Feature Manual References
None
For Output (EIO)—Device Type
Selects the type of connected output device (for output ports only).
Default
Door Opener
Value Range
Relay, Ringer, Door Opener
Maintenance Console Location
2.7.10 [1-1] Slot—DPH Card Property
Programming Manual References
2.11.6 [5-4] External Relay
Feature Manual References
1.4.9 Door Open
1.5.8 External Relay
For Sensor (EIO)—Input Signal Decision Time
Specifies the minimum duration of continuous...

Page 92

2.7 [1] Configuration
92 PC Programming Manual
Default
10 s
Value Range
10 × n (n=1–255) s
Maintenance Console Location
2.7.10 [1-1] Slot—DPH Card Property
Programming Manual References
None
Feature Manual References
1.5.9 External Sensor
2.7.11 [1-1] Slot—DPH Port Command
Commands for the DPH ports can be programmed.
INS
Puts the port in service.
Default
Not applicable.
Value Range
Not applicable.
Maintenance Console Location
2.7.11 [1-1] Slot—DPH Port Command
Programming Manual References
2.7.10 [1-1]...

Page 93

2.7 [1] Configuration
PC Programming Manual 93
Value Range
Not applicable.
Maintenance Console Location
2.7.11 [1-1] Slot—DPH Port Command
Programming Manual References
2.7.10 [1-1] Slot—DPH Card Property
Feature Manual References
None
2.7.12 [1-2] Portable Station
Various portable station (PS) settings can be programmed. A maximum of 28 PSs can be registered.
PS Registration and De-registration
A PS must be registered to the PBX by programming both the PBX and PS before it can be used. 
Programming...

Page 94

2.7 [1] Configuration
94 PC Programming Manual
2.Highlight numbers and click the right arrow to select them for de-registration. Click Next.
A dialog box will appear.
3.Click Confirm.
 If the de-registration is successful, the dialog box will show De-registration Succeed.
 If the de-registration is unsuccessful, the dialog box will show De-registration Error. 
De-registration will be terminated.
4.Click Close.
If the PS is successfully de-registered, the status of the PS will update to show None....

Page 95

2.7 [1] Configuration
PC Programming Manual 95
Feature Manual References
1.13.11 PS Connection
Index
Indicates the PS number (reference only).
Default
Not applicable.
Value Range
1–28
Maintenance Console Location
2.7.12 [1-2] Portable Station
Programming Manual References
None
Feature Manual References
1.13.11 PS Connection
Extension No.
Specifies the extension number of the PS.
In Wireless XDP Parallel Mode, the PS can be used as a sub telephone with a wired main telephone 
(PT/SLT), and two of them...

Page 96

2.7 [1] Configuration
96 PC Programming Manual
Extension Name
Specifies the name of the PS.
Default
Not stored.
Value Range
Max. 20 characters
Maintenance Console Location
2.7.12 [1-2] Portable Station
Programming Manual References
2.10.8 [4-2-1] Portable Station—Extension Settings—Main—Extension Name
Feature Manual References
1.13.11 PS Connection
Status
Indicates whether a certain PS is registered (reference only).
Default
None
Value Range
None, Registered
Maintenance Console Location
2.7.12 [1-2]...

Page 97

2.7 [1] Configuration
PC Programming Manual 97
automatically when a CS is connected to the PBX. Without the Radio System ID, PSs cannot be 
registered.
System Wireless—System ID
Indicates the radio system ID used to register a PS (reference only).
Default
Not stored.
Value Range
Not applicable.
Maintenance Console Location
2.7.13 [1-3] Option
Programming Manual References
None
Feature Manual References
None
New Card Installation—Card Status for any Card
Selects the initial status of cards after...

Page 98

2.7 [1] Configuration
98 PC Programming Manual
Value Range
Disable, Enable
Maintenance Console Location
2.7.13 [1-3] Option
Programming Manual References
None
Feature Manual References
None 

Page 99

2.8 [2] System
PC Programming Manual 99
2.8 [2] System
2.8.1 [2-1] Date & Time/Daylight Saving
The date and time of the PBX, and Summer time (daylight saving time) can be programmed. Summer 
time sets the clock one hour forward at 2:00 AM on the start date, and one hour back at 2:00 AM on 
the end date. The start and end dates of a maximum of 20 different summer times can be 
programmed.
To set the system date and time of the PBX, click 2.8.2 [2-1] Date & Time/Daylight Saving—Date 
& Time Setting....

Page 100

2.8 [2] System
100 PC Programming Manual
Programming Manual References
None
Feature Manual References
1.1.7 Automatic Time Adjustment
End Date—Year, Month, Day
Specifies the end date of daylight savings time.
Default
Year: 2005 (For Daylight Saving Time number 1. The year advances by one for the subsequent 
Daylight Saving Times.)
Month: 10
Day: Day of the last Sunday of the month
Value Range
Year: 2000–2099
Month: 1–12
Day: 1–31
Maintenance Console Location
2.8.1 [2-1] Date & Time/Daylight Saving...