Page 291
2.10 [4] Extension PC Programming Manual 291 Maintenance Console Location 2.10.2 [4-1-2] Wired Extension—FWD/DND Programming Manual References None Feature Manual References 1.6.6 FWD (Call Forwarding) FWD No Answer Timer Specifies the length of time that an incoming call rings at the extension before the call is forwarded. Default 15 s Value Range 0–120 s Maintenance Console Location 2.10.2 [4-1-2] Wired Extension—FWD/DND Programming Manual References None Feature Manual References 1.6.6 FWD (Call...
Page 292
2.10 [4] Extension 292 PC Programming Manual Maintenance Console Location 2.10.3 [4-1-3] Wired Extension—Speed Dial Programming Manual References None Feature Manual References 1.16.3 Speed Dialing, Personal Dialing Number Specifies the number to be dialed by the Personal Speed Dialing number. Default Not stored. Value Range Max. 32 digits (consisting of 0–9, *, #, T [Transfer], [ ] [Secret], P [Pause], and F [Flash]) Maintenance Console Location 2.10.3 [4-1-3] Wired Extension—Speed Dial Programming...
Page 293
2.10 [4] Extension PC Programming Manual 293 Hurry-up, Wrap-up, System Alarm, Time Service, Answer, Release, TRS Level Change, Time Service - Automatic/Manual, Two-way Record, Two-way Transfer, LCS, Voice Mail Transfer Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.10.5 [4-1-4] Wired Extension—Flexible Button—Flexible Button Data Copy Feature Manual References 1.6.3 Flexible Buttons Parameter Selection (for Single CO) Specifies the CO line to...
Page 294
2.10 [4] Extension 294 PC Programming Manual Feature Manual References 1.3.11 CO Line Access Parameter Selection (for Call Park) Specifies whether a call is parked in an idle parking zone automatically or in a specific parking zone. Default Automatic Value Range Automatic, Specific Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References None Feature Manual References 1.3.5 Call Park Parameter Selection (for Log-in/Log-out) Specifies which incoming call...
Page 295
2.10 [4] Extension PC Programming Manual 295 Default All Value Range All (Day/Night/Lunch/Break), Day/Night/Break, Day/Night/Lunch, Day/Night Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.8.5 [2-4] Week Table Feature Manual References 1.17.4 Time Service Parameter Selection (for TRS Level Change) Specifies the TRS level to be used temporarily on a certain extension. Default 1 Value Range 1–7 Maintenance Console Location 2.10.4 [4-1-4] Wired...
Page 296
2.10 [4] Extension 296 PC Programming Manual Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.8.5 [2-4] Week Table Feature Manual References 1.17.4 Time Service Ext No. / Floating Ext. No. (for DSS) Specifies the number of an extension to be accessed. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References None Feature Manual...
Page 297
2.10 [4] Extension PC Programming Manual 297 Ext No. / Floating Ext. No. (for Message Waiting) Specifies the number of an extension or floating extension number of an incoming call distribution group for which messages are checked. If this cell is left empty, the extension will check its own messages only. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References None Feature Manual...
Page 298
2.10 [4] Extension 298 PC Programming Manual Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD Feature Manual References 1.6.6 FWD (Call Forwarding) Ext No. / Floating Ext. No. (for Group FWD (Internal)) Specifies the floating extension number of an incoming call distribution group for which intercom calls are...
Page 299
2.10 [4] Extension PC Programming Manual 299 Programming Manual References None Feature Manual References 1.3.3 Call Log, Incoming Ext No. / Floating Ext. No. (for Log-in/Log-out) Specifies the floating extension number of an incoming call distribution group to log-in to or log-out from. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution...
Page 300
2.10 [4] Extension 300 PC Programming Manual Ext No. / Floating Ext. No. (for Two-way Record) Specifies the floating extension number of the VM (DPT) group containing the extensions mailbox. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.9.15 [3-7-2] VM(DPT) Group—Unit Settings Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration Ext No. / Floating Ext. No. (for...