Page 261
2.10 [4] Extension PC Programming Manual 261 Pickup Dial Number Specifies the number to be dialed automatically after going off-hook when the Hot Line feature is active. Default Not stored. Value Range Max. 32 digits (consisting of 0–9, *, #, T [Transfer], [ ] [Secret], P [Pause], and F [Flash]) Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.8.6 Hot Line Data Mode Sets or cancels the protection against tones...
Page 262
2.10 [4] Extension 262 PC Programming Manual Value Range Slot number Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References None Por t Indicates the port number (reference only). Default Current port number Value Range Port number Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.7.4 [1-1] Slot—Extension Port Feature Manual References None Extension Number...
Page 263
2.10 [4] Extension PC Programming Manual 263 Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.7.5 [1-1] Slot—Extension Port—Port Command Feature Manual References None Extension Name Specifies the name of the extension. Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual...
Page 264
2.10 [4] Extension 264 PC Programming Manual Feature Manual References 1.3.6 Call Pickup Executive Override Deny Specifies whether calls can be interrupted by other extensions. Default Disable Value Range Disable: Allows other extension users to interrupt an existing call Enable: Prevents other extension users from interrupting an existing call Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.5.3 Executive Busy...
Page 265
2.10 [4] Extension PC Programming Manual 265 Default Current slot number Value Range Slot number Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References None Por t Indicates the por t number (reference only). Default Current port number Value Range Port number Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.7.4 [1-1] Slot—Extension Port Feature Manual...
Page 266
2.10 [4] Extension 266 PC Programming Manual Default Starting at 101 (For port 01 of the first extension card that is installed. Extension numbers are preset for subsequent extensions by adding one to the previous extension number.) Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.7.5 [1-1] Slot—Extension Port—Port Command Feature Manual References None Extension Name Specifies the name of the...
Page 267
2.10 [4] Extension PC Programming Manual 267 F-1–F-12: A CO line programmed for a flexible CO button (F-1–F-12) is seized. A flexible CO button customized as a Single-CO, Group-CO, Loop-CO, or ICD Group button must be selected. Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.10.4 [4-1-4] Wired Extension—Flexible Button Feature Manual References 1.10.3 Line Preference—Outgoing Incoming Preferred Line Selects the line on which an incoming call...
Page 268
2.10 [4] Extension 268 PC Programming Manual Programming Manual References None Feature Manual References 1.9.11 Intercom Call Call Waiting Tone Type Selects the type of Call Waiting tone sent to the busy extension. Default CW Tone 1 Value Range CW Tone 1, CW Tone 2 Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.3.9 Call Waiting Tone LCS Recording Mode Specifies whether to continue or stop recording the message...
Page 269
2.10 [4] Extension PC Programming Manual 269 Default Hands free Value Range Hands free: Monitor through the built-in speaker Private: Monitor through the handset or the built-in speaker after hearing a warning tone Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.8.2 Hands-free Operation 1.19.4 Voice Mail DPT (Digital) Integration Display Language Selects the display language of the extension telephone. Default...
Page 270
2.10 [4] Extension 270 PC Programming Manual Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References None Por t Indicates the port number (reference only). Default Current port number Value Range Port number Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.7.4 [1-1] Slot—Extension Port Feature Manual References None Extension Number Specifies the extension...