Page 271
2.10 [4] Extension PC Programming Manual 271 Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.7.5 [1-1] Slot—Extension Port—Port Command Feature Manual References None Extension Name Specifies the name of the extension. Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References None Incoming Call Display Selects...
Page 272
2.10 [4] Extension 272 PC Programming Manual Automatic LCD Switch when Start Talking Enables the first line of the display to show the call duration automatically after answering a CO line call. Default Enable Value Range Disable, Enable Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.4.7 Display Information Key Pad Tone Specifies whether key pad tones are heard when dialing. Default On Value Range Off, On...
Page 273
2.10 [4] Extension PC Programming Manual 273 Value Range Disable, Enable Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.8.1 Hands-free Answerback Forced Automatic Answer Specifies whether the extension automatically answers all incoming calls (both intercom and CO line calls) without going off-hook, regardless of the Hands-free Answerback setting. Default Off Value Range Off, On Maintenance Console Location...
Page 274
2.10 [4] Extension 274 PC Programming Manual Programming Manual References None Feature Manual References None Option 6 Slot Indicates the slot position of each extension card (reference only). Default Current slot number Value Range Slot number Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References None Por t Indicates the port number (reference only). Default Current port number Value Range Port number Maintenance...
Page 275
2.10 [4] Extension PC Programming Manual 275 Extension Number Specifies the extension number of the extension. To change the extension number of a wired extension, follow the steps below: 1.Type the new extension number, then click Apply. 2.Set the status of the extension port to OUS, then INS. When changing the extension number, make sure that the extension port is not in use. If the extension number is changed while the por t is in use, the new extension number will not come into effect. Note that...
Page 276
2.10 [4] Extension 276 PC Programming Manual Display Lock / SVM Lock Locks or unlocks the Incoming Call Log and Simplified Voice Message Log display (i.e., specifies whether other extension users can see the Incoming Call Log and SVM Log information at the extension). Default Unlock Value Range Unlock, Lock Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.10.7 [4-1-6] Wired Extension—Simplified Voice Message Feature Manual References 1.3.3...
Page 277
2.10 [4] Extension PC Programming Manual 277 Value Range EFA, Terminate, Flash Recall Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.5.1 EFA (External Feature Access) 1.6.2 Flash/Recall/Terminate Incoming Call Log Memory Specifies the number of incoming CO line calls that are retained in the extensions Incoming Call Log memory. Default 10 Value Range 0–100 Maintenance Console Location 2.10.1 [4-1-1] Wired...
Page 278
2.10 [4] Extension 278 PC Programming Manual Programming Manual References None Feature Manual References None Option 7 Slot Indicates the slot position of each extension card (reference only). Default Current slot number Value Range Slot number Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References None Por t Indicates the port number (reference only). Default Current port number Value Range Port number Maintenance...
Page 279
2.10 [4] Extension PC Programming Manual 279 Extension Number Specifies the extension number of the extension. To change the extension number of a wired extension, follow the steps below: 1.Type the new extension number, then click Apply. 2.Set the status of the extension port to OUS, then INS. When changing the extension number, make sure that the extension port is not in use. If the extension number is changed while the por t is in use, the new extension number will not come into effect. Note that...
Page 280
2.10 [4] Extension 280 PC Programming Manual Extension Caller ID Sending Enables the extension to send Caller ID information to an SLT. Note that the setting of this parameter is only effective when a resource for sending extension Caller ID is assigned in Extension Caller ID Resource-1, 2 for the port in 2.8.18 [2-10] Extension CID Settings. Default Enable Value Range Disable, Enable Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.8.18...