Panasonic Kx Taw848 PC Cprogramming Manual
Here you can view all the pages of manual Panasonic Kx Taw848 PC Cprogramming Manual. The Panasonic manuals for Wireless PBX are available online for free. You can easily download all the documents as PDF.
Page 341
2.10 [4] Extension PC Programming Manual 341 Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD Feature Manual References 1.6.6 FWD (Call Forwarding) Ext No. / Floating Ext. No. (for Group Fwd (External)) Specifies the floating extension number of an incoming call distribution group for which CO line calls are forwarded. Default Not stored. Value Range Max. 4...
Page 342
2.10 [4] Extension 342 PC Programming Manual Ext No. / Floating Ext. No. (for Log-in/Log-out) Specifies the floating extension number of an incoming call distribution group to log-in to or log-out from. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Feature Manual References 1.9.3 ICD Group Features—Log-in/Log-out Ext...
Page 343
2.10 [4] Extension PC Programming Manual 343 Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References 2.9.15 [3-7-2] VM(DPT) Group—Unit Settings Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration Ext No. / Floating Ext. No. (for Two-way Transfer) Specifies the floating extension number of the VM (DPT) group containing the desired mailbox. Default Not stored. Value Range Max. 4 digits...
Page 344
2.10 [4] Extension 344 PC Programming Manual Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration 1.19.5 Voice Mail DTMF Integration Dial (for One-touch) Specifies the number to be dialed. The PBX can have a maximum of 500 One-touch Dialing buttons for PSs. Default Not stored. Value Range Max. 32 digits (consisting of 0–9, *, #, T [Transfer], [ ] [Secret], P [Pause], and F [Flash]) Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual...
Page 345
2.10 [4] Extension PC Programming Manual 345 Default 0 Value Range 0–99 Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References None Feature Manual References 1.3.5 Call Park Ext. No. of Mailbox (for Two-way Transfer) Specifies the number of the extension whose mailbox will be used to record conversations using One- touch Two-way Transfer. (For example, a secretary can record a conversation into the mailbox of a boss.) If the cell is left empty, the...
Page 346
2.10 [4] Extension 346 PC Programming Manual Maintenance Console Location 2.10.11 [4-2-3] Portable Station—Flexible Button—Flexible Button Data Copy Programming Manual References 2.10.10 [4-2-3] Portable Station—Flexible Button Feature Manual References None 2.10.12 [4-2-4] Portable Station—Simplified Voice Message When an SVM card is installed in the PBX, Simplified Voice Message features can be provided for each PS. This screen allows you to specify which card each extension belongs to, and the...
Page 347
2.10 [4] Extension PC Programming Manual 347 Maintenance Console Location 2.10.12 [4-2-4] Portable Station—Simplified Voice Message Programming Manual References 2.10.8 [4-2-1] Portable Station—Extension Settings2.7.12 [1-2] Portable Station—Extension Name Feature Manual References None Simplified Voice Message Selects which SVM card to use to store and play back greetings and messages for the extension. Each extension must be assigned to a specific SVM card, and can only use the assigned card. If two...
Page 348
2.10 [4] Extension 348 PC Programming Manual Feature Manual References 1.16.5 SVM (Simplified Voice Message) 2.10.13 [4-3] DSS Console—Flexible Button A DSS Console can be used in conjunction with a PT. A maximum of 4 DSS Consoles can be programmed. The DPT Type—Type (for Hybrid port) of the extension port that DSS Console is connected must be set to DSS in 2.7.4 [1-1] Slot—Extension Port. Each flexible DSS button can be customized to access a certain feature. A maximum of 66 flexible DSS buttons can...
Page 349
2.10 [4] Extension PC Programming Manual 349 Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.10.14 [4-3] DSS Console—Flexible Button—Flexible button Data Copy Feature Manual References 1.6.3 Flexible Buttons Parameter Selection (for Single CO) Specifies the CO line to be accessed. Default 1 Value Range 1–8 Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References None Feature Manual References 1.3.11 CO Line...
Page 350
2.10 [4] Extension 350 PC Programming Manual Parameter Selection (for Call Park) Specifies whether a call is parked in an idle parking zone automatically or in a specific parking zone. Default Automatic Value Range Automatic, Specific Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References None Feature Manual References 1.3.5 Call Park Parameter Selection (for Log-in/Log-out) Specifies which incoming call distribution groups that the paired extension belongs...