Page 351

2.10 [4] Extension
PC Programming Manual 351
Value Range
All (Day/Night/Lunch/Break), Day/Night/Break, Day/Night/Lunch, Day/Night
Maintenance Console Location
2.10.13 [4-3] DSS Console—Flexible Button
Programming Manual References
2.8.5 [2-4] Week Table
Feature Manual References
1.17.4 Time Service
Parameter Selection (for TRS Level Change)
Specifies the TRS level to be used temporarily on a certain extension.
Default
1
Value Range
1–7
Maintenance Console Location
2.10.13 [4-3] DSS Console—Flexible...

Page 352

2.10 [4] Extension
352 PC Programming Manual
Programming Manual References
2.8.5 [2-4] Week Table
Feature Manual References
1.17.4 Time Service
Ext. No. / Floating Ext No. (for DSS)
Specifies the number of an extension to be accessed.
Default
Not stored.
Value Range
Max. 4 digits (consisting of 0–9)
Maintenance Console Location
2.10.13 [4-3] DSS Console—Flexible Button
Programming Manual References
None
Feature Manual References
None
Ext. No. / Floating Ext No. (for ICD Group)
Specifies the floating...

Page 353

2.10 [4] Extension
PC Programming Manual 353
Ext. No. / Floating Ext No. (for Message Waiting)
Specifies the number of an extension or floating extension number of an incoming call distribution 
group for which messages are checked. If this cell is left empty, the paired extension will check its own 
messages only.
Default
Not stored.
Value Range
Max. 4 digits (consisting of 0–9)
Maintenance Console Location
2.10.13 [4-3] DSS Console—Flexible Button
Programming Manual References
None
Feature Manual...

Page 354

2.10 [4] Extension
354 PC Programming Manual
Value Range
Max. 4 digits (consisting of 0–9)
Maintenance Console Location
2.10.13 [4-3] DSS Console—Flexible Button
Programming Manual References
2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD
Feature Manual References
1.6.6 FWD (Call Forwarding)
Ext. No. / Floating Ext No. (for Group Fwd (Internal))
Specifies the floating extension number of an incoming call distribution group for which intercom calls 
are forwarded....

Page 355

2.10 [4] Extension
PC Programming Manual 355
Programming Manual References
None
Feature Manual References
1.3.3 Call Log, Incoming
Ext. No. / Floating Ext No. (for Log-in/Log-out)
Specifies the floating extension number of an incoming call distribution group to log-in to or log-out 
from.
Default
Not stored.
Value Range
Max. 4 digits (consisting of 0–9)
Maintenance Console Location
2.10.13 [4-3] DSS Console—Flexible Button
Programming Manual References
2.9.9 [3-5-1] Incoming Call Distribution Group—Group...

Page 356

2.10 [4] Extension
356 PC Programming Manual
Ext. No. / Floating Ext No. (for Two-way Record)
Specifies the floating extension number of the VM (DPT) group containing the paired extensions 
mailbox.
Default
Not stored.
Value Range
Max. 4 digits (consisting of 0–9)
Maintenance Console Location
2.10.13 [4-3] DSS Console—Flexible Button
Programming Manual References
2.9.15 [3-7-2] VM(DPT) Group—Unit Settings
Feature Manual References
1.19.4 Voice Mail DPT (Digital) Integration
Ext. No. / Floating Ext No....

Page 357

2.10 [4] Extension
PC Programming Manual 357
Value Range
Max. 4 digits (consisting of 0–9)
Maintenance Console Location
2.10.13 [4-3] DSS Console—Flexible Button
Programming Manual References
2.9.15 [3-7-2] VM(DPT) Group—Unit Settings
2.9.18 [3-8-2] VM(DTMF) Group—Group Settings
Feature Manual References
1.19.4 Voice Mail DPT (Digital) Integration
1.19.5 Voice Mail DTMF Integration
Dial (for One-touch)
Specifies the number to be dialed. The PBX can have a maximum of 2000 One-touch Dialing buttons 
for...

Page 358

2.10 [4] Extension
358 PC Programming Manual
Programming Manual References
2.8.5 [2-4] Week Table
Feature Manual References
1.17.4 Time Service
Optional Parameter (Ringing Tone Type Number) (for Call Park)
Specifies the number of the parking zone a call is to be parked in when a Call Park button with 
Parameter Selection (for Call Park) on this screen set to Specific is pressed.
Default
0
Value Range
0–99
Maintenance Console Location
2.10.13 [4-3] DSS Console—Flexible Button
Programming Manual...

Page 359

2.10 [4] Extension
PC Programming Manual 359
2.10.14 [4-3] DSS Console—Flexible Button—Flexible button Data 
Copy
The flexible DSS button settings of a DSS Console can be copied to different DSS Consoles. Select 
the DSS Console that has the setting to copy to other DSS Consoles from the DSS Console No./ 
Pair Extension list, then click Copy To.
Destination DSS Console
Select the number of the DSS Console and paired extension. Multiple DSS Consoles can be 
selected. To select all DSS Consoles at once,...

Page 360

2.11 [5] Optional Device
360 PC Programming Manual
2.11 [5] Optional Device
2.11.1 [5-1] Doorphone
The settings to establish doorphone calls can be programmed. 
To assign destinations for doorphone calls easily, click Extension Number of Destination Setting 
(see 
2.1.6 Extension Number Setting).
Physical—Slot
Indicates the slot to which the doorphone is connected (reference only).
Default
Current slot number
Value Range
Slot number
Maintenance Console Location
2.11.1 [5-1] Doorphone
Programming Manual...