Page 61
61 No.Procedure Press [+] [0] [3] [enter]. The short electronic sound PiPi is heard. Enter one of the following. English: Press [0] [1] [enter] Japanese: Press [0] [2] [enter] German: Press [0] [3] [enter] French: Press [0] [4] [enter] Italian: Press [0] [5] [enter] Spanish: Press [0] [6] [enter] Russian: Press [0] [7] [enter] Chinese: Press [0] [8] [enter] Korean: Press [0] [9] [enter] Arabic: Press [1] [0] [enter] Portuguese: Press [1] [1] [enter] Turkish: Press [1] [2] [enter] Dutch: Press [1] [3]...
Page 62
62 Select the Recognition Method The following is how to select the recognition method. No.Procedure Press [+] [0] [8] [enter]. The short electronic sound PiPi is heard. Select the recognition method. •When performing iris recognition only, press [0] [enter]. •When performing iris recognition and PIN recognition, press [1] [enter]. The voice guidance will say, Registration has been completed. Note:When the voice guidance says, Registration has been failed., retry Step 2. 1 2 accept reject accept reject...
Page 63
63 Setup (Network Mode) This section describes the settings of network mode. The administration software is used for setup. Refer to BM-ES200 Operating Instructions (supplied to Administration Software BM-ES200) for details on network mode opera- tion. Connection and Setup Flow Connection and setup are performed before the iris reader is used in the network mode. Detach the front cover from the iris reader. (Refer to p. 28.) Make sure that the power is not supplied to the iris reader. Perform the setup...
Page 64
64 Registering Administrators The following are descriptions of how to register administrators in the network mode. In the network mode, registration of at least one administrator is required. In the factory default setting, there are no administrators. At the time of initial setup, surely register an administrator. Up to three administrators can be registered. Reader ID: 1 IP Address: 192.168.0.3 Server IP Address: 192.168.0.2 Subnet Mask: 255.255.255.0 Gateway IP Address: No setting Refer to p. 43 for...
Page 65
65 About the Operation Window [Reader Setting] button Click this button to display the Reader Setting page. The reader ID settings and the network settings can be configured on the Reader Setting page. [Administrator] button Click this button to display the Administrator List page. It is possible to check or register the administrator informa- tion on the Administrator List page.Main area Pages of each setup menu will be displayed. [Reader ID] [IP Address] Refer to p. 52. [Server IP Address] Enter the IP...
Page 66
66 Register administrators [Administrator List] Click the [Administrator List] tab button to display the Administrator List page. Up to three administrators can be registered. Step 1 Click the [New] button. →The Administrator screen is displayed. Step 2 Complete each setting item displayed in the frame on the right of the window. Notes: •Refer to p. 42 for details on setting items. •In the network mode, iris registration by the web brows- er control is unavailable. Step 3 Click the [Register] button....
Page 67
67 Instructions for Proper Enrollment and Recognition You (user) should follow the instructions mentioned in this page for proper enrollment and recognition. • Open your eyes as wide as you can so as not to hide the irises with eyelids and eyelashes. • For users wearing glasses/sunglasses (for enrollment) Take off the glasses when enrolling the iris data. • For users wearing glasses/sunglasses (for recognition) With this iris reader, you can carry out iris recognition wearing glasses. However, in the...
Page 68
68 Operating Procedures (Instructions for Users) How to Position Your Eyes in the Mirror This iris reader captures the iris data of both eyes at one time. If the eyes are not positioned within the capturing range, enroll- ment/recognition will be invalid. Before enrollment/recognition, you (the user) should stand in front of the iris reader as follows and adjust your eye position. Even when you carry out enrollment/recognition while sitting, you should adjust your eye position in the same way. Note:If...
Page 69
69 Open your eyes widely and look at the mirror from the front side. Open your eyes as wide as you can so as not to hide the irises with eyelids and eyelashes. Adjust your eye position by following the distance indicator or voice guidance from the speaker. The distance indicator consists of five lamps. When a user comes to the position that is most suitable for capturing, all the five lamps light up. The number of lighting lamp decreases when the distance between the iris reader and you is closer. When...
Page 70
70 Move your position slowly by following the distance indicator or voice guidance. •When the distance between the iris reader and you is too far, the voice guidance will say, Please move a little closer. •When the distance between the iris reader and you is too short, the voice guidance will say, Please move back a little. 5 accept reject accept reject Cases of Enrollment/Recognition Failure •You have closed your eyes or not opened your eyes widely enough during the capturing procedure. •You were...