Page 21
8 Pin No. 21 1 2 3 4 5 6 7 OFF Tamper detection cancelCancels the tamper detection. Set this switch to ON when the front cover is removed for servicing.Cancel Detect After servicing, set this switch to OFF. If the front cover is attached with this switch ON, buzzer sound is activat- ed. OFF Ethernet Full/Half Ethernet setting Half Full Available only when 5 is ON OFF Ethernet 100 M/ 10 MEthernet setting 10 M 100 M Available only when 5 is ON OFF Ethernet auto- negotiationEthernet setting Fixed...
Page 22
Pin No. Pin No. 22 SW1-1 SW1-2 OFF RS-485 termination (card reader)Selects whether to activate the termina- tion of the RS-485 connection with the card reader.RS-485 ter- mination ONRS-485 ter- mination OFF or WiegandAvailable only when SW2-3 and SW2-4 are OFF (RS- 485 is selected). When selecting Wiegand, surely set this switch to OFF. Otherwise, communication may not be established. Factory default OFF RS-485 termination (access control panel)Selects whether to activate the termina- tion of the RS-485...
Page 23
23 Cautions: • Attach this iris reader to a flat wall. After the installation, secure the iris reader to prevent dropping. • This system must be installed within the protected premise in accordance with the National Electrical Code(NFPA70), and local authorities having jurisdiction. • All interconnecting devices must be UL listed. • Alarm output2 (tamper detection) must be connected to UL Listed Access Control Panels to disable operation during tamper alarm. Installation and Connections ON 1234ON 1234 +...
Page 24
Power cable (Mandatory) 24 Description about the Connection Example • When the power supply is shut down, an alarm signal is supplied from the alarm output 1 (power status) to alarm devices. • When the front cover is removed from an iris reader or the iris reader is removed from the wall, an alarm signal is sent from the alarm output 2 (tamper detection) to alarm devices. • When recognition is not successfully completed, an alarm signal is sent from the recognition result output 2 (REJECT) to a digital...
Page 25
25 Item Junction box Rear cover fixing screw (Mandatory) GND cable (Mandatory) _ Solder both ends of the cable with M3 screw clamp terminals. Use the supplied earth ground cable to connect the earth ground. Two gang junction box (4 in. x 4 in.) Necessary when attaching the rear cover to the wall Item number/Recommended type Use *1Only cables without connector covers are usable. Notes: • When you use the alarm output and Wiegand terminals, you need optional cables suited for the connectors of external...
Page 26
26 •Incandescent or halogen lighting •Places where the iris reader or the users eyes are directly exposed to light Notes:(A quantity of acceptable near-infrared ray is 500 µW/cm 2or less.) •Places near the light reflection (from a mirror, etc.) •Places where the amount of light is not appropriate for operation Keep the iris reader away in the following, in addition to the above surroundings. •Vibration (It may cause invalid iris image capturing and recognition. It may also cause other trouble or...
Page 27
27 Check the Capturing Range. If the height of the iris reader is 1 240 mm {48.8 in.} as described in the previous Side View illustration, the recognition range will become as follows. Note:If your eye position is higher than the upside limit, bend down. If your eye position is lower than the downside limit, get on a pedestal, etc. 0 12 mm {0.47 in.} 300 mm {12 in.} 400 mm {15.7 in.}1 678 mm {66.1 in.} Upside limit of the eye position 1 395 mm {54.9 in.} Center of optical axis (Recommended installation...
Page 28
3. Detach the rear cover from the main unit by removing the mounting screws. 4. Secure the rear cover to the wall or junction box built in a wall with the locally procured screws, and fix the tam- per detection lever on the wall. Important: •To work tamper detection properly, mount tamper lever to the wall by screw. •The tamper detection lever is crucial to function of the tamper, and needs to be attached securely to the wall for the tamper to work properly. 5. Attach the main unit to the rear cover. (1)...
Page 29
29 6. Connect the LAN cable and audio output cable to the iris reader. Attach the ferrite core supplied to the LAN cable and audio output cable. 7. Fix the power cable to the iris reader with the supplied clamping tool and clamping screw. (Cut off the extra portion of clamping tool.) 8. Connect the DC 12 V or DC 24 V power cable to the iris reader. Important: •Do not mistake + and –. The wrong cable connec- tion may cause trouble. •Do not connect an AC power-supply device. The iris reader works 12 V...
Page 30
30 (2) Insert the option camera firmly into the CN6 con- nector until the connector clicks. (3) Insert the video output cable supplied to the option camera firmly into the CN7 connector, and connect the video output cable of the option camera to the the video input cable connected to an external device (for example, a digital disk recorder). 14. Remove the sheet from the back side of front cover. 15. Attach the front cover to the main unit. Fit the screw hole and protrusions of front cover in the main...