ADVANCED MENU
ENGLISH - 51
Settings
INPUT RESOLUTION
Input resolution adjustment achieves the best image 
when the screen flickers or halo is observed around 
the contour. Set the values appropriately for the signal 
resolution that is being used.
Press ▲▼ to select [INPUT 
1  ) 
RESOLUTION].
Press  button.
2  ) 
The [INPUT RESOLUTION] screen will be  
z
displayed.
Press ▲▼ to select [TOTAL DOTS], 
3  ) 
[DISPLAY DOTS], [TOTAL LINES] or 
[DISPLAY LINES], and the press ◄► 
to adjust it.
Each item...

Page 52

52 - ENGLISH
Settings
DISPLAY LANGUAGE menu
See  
z“Navigating through the menu ”  
(
Æpage 39).
See 
 
z“MAIN MENU” and “SUB MENU ”  
(
Æpage 40).
Changing the display 
language
This lets you switch the on-screen display language.
Menus, setting items, adjustment screens, and  
z
control button names will be displayed in the 
language the user chooses.
The available languages are: English, German 
 
z
(DEUTSCH), French (FRANÇAIS), Spanish 
(ESPAÑOL), Italian (ITALIANO), Japanese 
( 
 ), Chinese (  ),...

Page 53

ENGLISH - 53
Settings
See  
z“Navigating through the menu ”  
(
Æpage 39).
See 
 
z“MAIN MENU” and “SUB MENU ”  
(
Æpage 40).
COLOR MATCHING
When multiple sets are used simultaneously, this 
projector allows the user to correct the difference of 
colors among the sets.
Press ▲▼ to select [COLOR 
1  ) 
MATCHING].
Press ◄► to switch [COLOR 
2  ) 
MATCHING].
The setting will change as follows each time  
z
◄► is pressed.
OFF3COLORS
MEASURED7COLORS
OFF Color matching adjustment is not 
carried out.
3COLORS...

Page 54

DISPLAY OPTION menu
54 - ENGLISH
Settings
Use the colorimeter to measure 
6  ) 
the luminance (Y) and chromaticity 
coordinates (x, y)
Press ▲▼ to select the colors, and 
7  ) 
press ◄► to select their values.
If [AUTO TEST PATTERN] is turned [ON],  
z
the test pattern of the selected color is 
displayed.
After all the data has been input, 
8  ) 
press  button.
The [ 
zMEASURED MODE] screen will be 
displayed.
Inputting the coordinates of a desired  
Q
color
Press ▲▼ to select [TARGET 
9  ) 
DATA].
Press...

Page 55

DISPLAY OPTION menu
ENGLISH - 55
Settings
WAVEFORM MONITOR  
(PT-DZ570U only)
This function displays the waveform of the input signal 
from a connected peripheral device.
You can check if the image output (BRIGHTNESS) 
signal level is within the range recommended by this 
projector and adjust it as necessary.
Press ▲▼ to select [WAVEFORM 
1  ) 
MONITOR].
Press ◄► to switch [WAVEFORM 
2  ) 
MONITOR].
The setting will change as follows each time  
z
◄► is pressed.
OFFON
Press the  button twice to turn 
3...

Page 56

DISPLAY OPTION menu
56 - ENGLISH
Settings
AUTO SETUP
Use this setting when adjusting a specific or oblong 
(16:9, etc.) signal.
Press ▲▼ to select [AUTO SETUP].
1  ) 
Press  button.
2  ) 
The [AUTO SETUP] screen will be displayed. 
z
Press ▲▼ to select [MODE].
3  ) 
Press ◄► to switch [MODE].
4  ) 
The setting will change as follows each time  
z
◄► is pressed.
DEFAULTWIDEUSER
DEFAULT To receive signals of which image 
aspect is 4:3 or 5:4  
(applicable resolution : 640 × 400, 
 
640 × 480, 800 × 600,...

Page 57

DISPLAY OPTION menu
ENGLISH - 57
Settings
RGB IN (Only RGB input)
Change this setting to change the input impedance of 
the synchronous signal input.
Press ▲▼ to select [RGB IN].
1  ) 
Press  button.
2  ) 
The [ 
zRGB IN] screen will be displayed.
Press ▲▼ to select [RGB1 SYNC 
3  ) 
TERMINAL] or [RGB2 SYNC 
TERMINAL].
Press ◄► to switch.
4  ) 
The setting will change as follows each time  
z
◄► is pressed.
LOWHIGH
LOW Input impedance is set to [LOW].
HIGH Input impedance is set to [HIGH].
DVI-D IN...

Page 58

DISPLAY OPTION menu
58 - ENGLISH
Settings
ON-SCREEN DISPLAY
The user can specify the on-screen display.
Press ▲▼ to select [ON-SCREEN 
1  ) 
DISPLAY].
Press  button.
2  ) 
The [ON-SCREEN DISPLAY] screen will be  
z
displayed.
Press ▲▼ to select the desired item, 
3  ) 
and press ◄► to change the setting.
 
JOSD POSITION
This sets the position of the on-screen display 
(OSD).
2 (Left center  
of the screen)3 (Bottom left  
of the screen)
4 (Top center  
of the screen)
1 (Top left 
 
of the screen)
5...

Page 59

DISPLAY OPTION menu
ENGLISH - 59
Settings
BACK COLOR
This sets the color for the projection screen when no 
signals are being input.
Press ▲▼ to select [BACK COLOR].
1  ) 
Press ◄► to switch [BACK COLOR].
2  ) 
The setting will change as follows each time  
z
◄► is pressed.
BLUEBLACK
LOGO2LOGO1
BLUE The entire projection area will 
appear blue.
BLACK The entire projection area will 
appear black.
LOGO1 The picture registered by the user 
will be projected in the projection 
area.
LOGO2 The Panasonic logo...

Page 60

DISPLAY OPTION menu
60 - ENGLISH
Settings
FREEZE
You can freeze the projected image and stop the 
sound temporarily, regardless of the playing condition 
of the connected device.
Press ▲▼ to select [FREEZE].
1  ) 
Press  button.
2  ) 
Press  button to escape. 
z
SIDE BY SIDE 
(PT-DZ570U and PT-DW530U only)
When a small sub -screen is placed in the main 
screen, dual images can be projected simultaneously.
Press ▲▼ to select [SIDE BY SIDE].
1  ) 
Press  button.
2  ) 
Dual screens are projected. 
z
Press...