Page 31

31
3. Select either ON or OFF with the JogDial.
The default is ON for all cameras.
ON:Enables camera title display, title registration, and
position selection.
OFF:Disables the camera title functions.
4. Press the JogDial (SET) to validate the selection.
When ON is selected, go to the following steps. The
cursor moves to the title edit area.
When OFF is selected, return to step 2 above, or press
the [SETUP/ESC] button to escape from the CAMERA
TITLE menu.
5. 
5-1 Select a character for the digit with the...

Page 32

32
2. Select either ON or OFF with the JogDial, and press the
JogDial.
The default is OFF.
ON:The buttons are password protected. The recorder
enters the button lock mode if neither a button nor
the JogDial is operated within a period of five min-
utes.
OFF:No password protection is applied.
3. Move the cursor to ALL
→or OPERATION→with the
[
D] or [C] button.
ALL:Allows both normal operations and setup opera-
tions.
OPERATION:Allows only normal operations. Setup
operations are not allowed.
4. Press the...

Page 33

33
•Simultaneous playback will pause prior to a time
space depending on the recording rate when the
playback area on the disk nears the recording area.
This is to avoid the access collision caused by the
simultaneous recording and playback in an area on
the disk.
0.1 FPS: 20 minutes maximum
1 FPS: 2 minutes maximum
7.5 FPS: 15 seconds maximum
15 FPS: 7 seconds maximum
•Even if preset to 30 or 15 FPS, the actual recording
rate may drop to 7.5 FPS at worst while busy multi-
tasks such as playback,...

Page 34

34
Time Adjust Setup
(TIME ADJUSTING)
IN and OUT terminals for a calibration signal are provided
on the rear panel. The master unit supplies the calibration
signal to the slave units once at the specified hour every-
day. The slave unit accepts the signal through the IN termi-
nal, and corrects its internal timer to the hour as far as the
clock deviates within 15 minutes after or before the hour.
This is convenient for synchronizing the internal clock with
other connected devices.
1. Move the cursor to...

Page 35

35
Alarm Setup (ALARM SETUP)
The digital disk recorder accepts alarm signals supplied
from connected devices such as sensors or camera site
equipment. The recorder itself also generates an alarm sig-
nal when the preset motion detection is activated. Any
alarm signal starts recording with the preset recording
mode, field rate, and picture quality specified in the REC
MODE menu described earlier. Alarm recording stops
when the preset time has elapsed, the alarm [RESET] but-
ton on the front panel is...

Page 36

36
Notes: 
•VMD should be used when the input to the unit is
from an ordinary camera. Select [OFF] to avoid use-
less VMD when a video multiplexer or combination
camera supplies the input to the unit.
•Set ALARM SUSPEND to ON when you do not want
VMD to be activated during the VMD setup.
•There may be cases where VMD does not suffi-
ciently detect changes, since it detects the
changes in luminance.
•The detection area may include areas slightly out-
side the border.
•The buzzer will beep if detection...

Page 37

37
Baud Rate (BAUD RATE)
1. Move the cursor to BAUD RATE with the [D] or [C] but-
ton.
2. Select the rate with the JogDial, and press the JogDial. 
The default value is 9600 bits per second.
4800:4 800 bps
9600:9 600 bps*
19200:19 200 bps
Data Bit (DATA BIT)
1. Move the cursor to DATA BIT with the [D] or [C] but-
ton.
2. Select the bit length with the JogDial. 
The default value is 8 bits.
7:7 bits* ; select when using RS-232C protocol.
8:8 bits
Parity Check (PARITY CHECK)
1. Move the cursor to PARITY...

Page 38

38
Camera Number Setup (CAM NO.
SETUP) (exclusive to PS
•DATA)
Camera numbers will be used in a PS•DATA chain when
you select a camera to control it from a system controller.
1. Move the cursor to CAM NO. SETUP
Owith the [D] or
[
C] button, and press the JogDial. The CAM NO.
SETUP menu opens.
2. Move the cursor to the desired line with the [
D] or [C]
button.
3. Select the number with the JogDial, and press the
JogDial.
The default number is the same as the CAM-PORT
number.
Assignable numbers:From 001...

Page 39

39
IP Address (IP ADDR)
The default is 192.168.000.010.
Netmask (NETMASK)
The default is 255.255.255.000.
Gateway (GATEWAY)
The default is 192.168.000.001.
Switcher Setup (SWITCHER
SETUP)
Video switcher functions are programmed in this menu
setup.
Start Display (START DISPLAY)
The image in the selected form will be displayed on the
monitor when the recorder is turned on.
Single image:CH 1 to CH 8
Quad image:QUAD-4A (including 1-4), QUAD-4B
(including 5-8)
Multi image:9SCREEN (including 1-8)...

Page 40

40
4. Repeat steps 1, 2, and 3 until all steps are pro-
grammed, or press the [SETUP/ESC] button to return to
the SEQUENCE SETUP menu.
5. Move the cursor to SEQUENCE TIMING in the SEQ
SETUP menu.
Select INT or EXT with the JogDial, and press the
JogDial.
The default is INT.
INT:Forwards the step when the assigned time elaps-
es.
EXT:Forwards the step when the SEQ IN signal is input
to the rear panel.
6. Move the cursor to AUTO SKIP with the [
D] or [C] but-
ton.
Select ON or OFF with the JogDial, and...