Page 31
31 3. Select either ON or OFF with the JogDial. The default is ON for all cameras. ON:Enables camera title display, title registration, and position selection. OFF:Disables the camera title functions. 4. Press the JogDial (SET) to validate the selection. When ON is selected, go to the following steps. The cursor moves to the title edit area. When OFF is selected, return to step 2 above, or press the [SETUP/ESC] button to escape from the CAMERA TITLE menu. 5. 5-1 Select a character for the digit with the...
Page 32
32 2. Select either ON or OFF with the JogDial, and press the JogDial. The default is OFF. ON:The buttons are password protected. The recorder enters the button lock mode if neither a button nor the JogDial is operated within a period of five min- utes. OFF:No password protection is applied. 3. Move the cursor to ALL →or OPERATION→with the [ D] or [C] button. ALL:Allows both normal operations and setup opera- tions. OPERATION:Allows only normal operations. Setup operations are not allowed. 4. Press the...
Page 33
33 •Simultaneous playback will pause prior to a time space depending on the recording rate when the playback area on the disk nears the recording area. This is to avoid the access collision caused by the simultaneous recording and playback in an area on the disk. 0.1 FPS: 20 minutes maximum 1 FPS: 2 minutes maximum 7.5 FPS: 15 seconds maximum 15 FPS: 7 seconds maximum •Even if preset to 30 or 15 FPS, the actual recording rate may drop to 7.5 FPS at worst while busy multi- tasks such as playback,...
Page 34
34 Time Adjust Setup (TIME ADJUSTING) IN and OUT terminals for a calibration signal are provided on the rear panel. The master unit supplies the calibration signal to the slave units once at the specified hour every- day. The slave unit accepts the signal through the IN termi- nal, and corrects its internal timer to the hour as far as the clock deviates within 15 minutes after or before the hour. This is convenient for synchronizing the internal clock with other connected devices. 1. Move the cursor to...
Page 35
35 Alarm Setup (ALARM SETUP) The digital disk recorder accepts alarm signals supplied from connected devices such as sensors or camera site equipment. The recorder itself also generates an alarm sig- nal when the preset motion detection is activated. Any alarm signal starts recording with the preset recording mode, field rate, and picture quality specified in the REC MODE menu described earlier. Alarm recording stops when the preset time has elapsed, the alarm [RESET] but- ton on the front panel is...
Page 36
36 Notes: •VMD should be used when the input to the unit is from an ordinary camera. Select [OFF] to avoid use- less VMD when a video multiplexer or combination camera supplies the input to the unit. •Set ALARM SUSPEND to ON when you do not want VMD to be activated during the VMD setup. •There may be cases where VMD does not suffi- ciently detect changes, since it detects the changes in luminance. •The detection area may include areas slightly out- side the border. •The buzzer will beep if detection...
Page 37
37 Baud Rate (BAUD RATE) 1. Move the cursor to BAUD RATE with the [D] or [C] but- ton. 2. Select the rate with the JogDial, and press the JogDial. The default value is 9600 bits per second. 4800:4 800 bps 9600:9 600 bps* 19200:19 200 bps Data Bit (DATA BIT) 1. Move the cursor to DATA BIT with the [D] or [C] but- ton. 2. Select the bit length with the JogDial. The default value is 8 bits. 7:7 bits* ; select when using RS-232C protocol. 8:8 bits Parity Check (PARITY CHECK) 1. Move the cursor to PARITY...
Page 38
38 Camera Number Setup (CAM NO. SETUP) (exclusive to PS •DATA) Camera numbers will be used in a PS•DATA chain when you select a camera to control it from a system controller. 1. Move the cursor to CAM NO. SETUP Owith the [D] or [ C] button, and press the JogDial. The CAM NO. SETUP menu opens. 2. Move the cursor to the desired line with the [ D] or [C] button. 3. Select the number with the JogDial, and press the JogDial. The default number is the same as the CAM-PORT number. Assignable numbers:From 001...
Page 39
39 IP Address (IP ADDR) The default is 192.168.000.010. Netmask (NETMASK) The default is 255.255.255.000. Gateway (GATEWAY) The default is 192.168.000.001. Switcher Setup (SWITCHER SETUP) Video switcher functions are programmed in this menu setup. Start Display (START DISPLAY) The image in the selected form will be displayed on the monitor when the recorder is turned on. Single image:CH 1 to CH 8 Quad image:QUAD-4A (including 1-4), QUAD-4B (including 5-8) Multi image:9SCREEN (including 1-8)...
Page 40
40 4. Repeat steps 1, 2, and 3 until all steps are pro- grammed, or press the [SETUP/ESC] button to return to the SEQUENCE SETUP menu. 5. Move the cursor to SEQUENCE TIMING in the SEQ SETUP menu. Select INT or EXT with the JogDial, and press the JogDial. The default is INT. INT:Forwards the step when the assigned time elaps- es. EXT:Forwards the step when the SEQ IN signal is input to the rear panel. 6. Move the cursor to AUTO SKIP with the [ D] or [C] but- ton. Select ON or OFF with the JogDial, and...