Page 142
DBS Programming Instructions WC-A / 3.0. CPC-B / 2.0 / 3.0 / 4.0 Chapter 1 General Program Outline Prior to programming the system make certain you have completed the following steps. Step 1: Corr6rn-r the DBS system feature operations meet the end userrequirements as outlined in Section 700. Step 2: ‘-“. ~ ,.,-’ : Prepare section 450 with the end users requirements. Step 3: Confirm the hardware required for the end user. _I._ ‘ :. ., Step 4: Initialize the system to the default...
Page 143
Section 400 FFl issue 2 July 1993 Before beginning to program a newly installed DHS for the first lime, set the system programs to the default values by following steps 1 through 5 below: 1.TurnoffthepowerfortheMainCabinet. (Both cabinets if a dual cabinet configuration is being used.) 2. Slide the CPC RAM switch to the CLEAR position. 3. Turn on the power for the Main Cabinet(s), then wait until the bottom LED on the CPC card stops flashhg. Note: The CPC-B card will take about twice as...
Page 144
DBS Programming Instructions WC-A / 3.0, CPC-B / 2.0 / 3.0 / 4.0 Chapter 2 Requirements for p~gramming Section 400 FFl Issue 3 July 1993 I 2-l PREPARING PROGRAMMING DATA TABLE I 2-2 HOW TOACCESS RR-G MODE Prior to programming the DBS, complete Section 450 (Programming Tables). Review the desired functionality with the end user, making any additional changes as required. Ifthe end user has requested specific functionality you are unfaxmliar with, refer to Section 700 to confum the . DBS...
Page 145
Section 400 FFl Issue 2 July 1993 DBS Ro@amming instructions CPC-A / 3.0. CPC-B / 2.0 / 3.0 / 4.0 When programming from a telephone connected to the test terminal (CN3) of the main DBS cabinet, slide the switch on the cabinet to the test mode. This switch provides a direct connection to ports 7 and 8. To enter the programming mode from the test terminal port, perform the following steps: [ON/OFF], #98,9999 (or presently used Authorization code), [PROG]. ##, then proceed with the FF key...
Page 146
DBS Programming Instructions CPC-A / 3.0, CPC-B / 2.0 / 3.0 / 4.0 Section 400 FFl Issue 3 JuIy 1993 When programming from a terminal connected to the RS232C (SMDR) port, perform the .following steps: 1. Make certain the cables are configured and connected as outlined in Section 300. 2. Make certain the DBS is in the SMDR mode by performing the following steps i?om the attendant port: !’ [ON/OFF], #93 ! 3. Perform the following steps from the terminal:.. . . #99, 9999 4. After the DBS...
Page 147
Section 400 FFl DBS Programming Instructions Issue 2 JuIy 1993 WC-A / 3.0. CPC-B / 2.0 / 3.0 / 4.0 2-3 PROG- G METHOD Example of date/time program entries: To set the date from extension port number 1: Press [ON/OFF], [PROG] (“F* is displayed), # (“F#” is displayed), # (“Program Mode” is displayed on line 1, “MAIN MODE” is displayed on line 2). Ffress [FFl]. (“System Program” is displayed on line 1, ‘SELECT SUB-MODE” is displayed on line 2). Press 1, #, (“Select Time Mode” is displayed...
Page 148
DBS Programming Instructions Section 400 FFl CPC-A / 3.0, CPC-B / 2.0 / 3.0 / 4.0 Issue 3 July 1993 Page Default Value (FFI [FFI [FFI [FFI [FF 1 (FF 1 (FFI [FFI [FFI [FFI [FFI [FFl [FFl [FFI (FFI [FFI i::; [FFI [FFI [FFl i [FFI [FFl [FFI [FFl IFFI -1-1 ............................ DAY/DATE ....................................................................... -1-2 ............................ TIME...
Page 149
Section 400 FFl DBS Pqpmming Insimction~ Issue 2 July 1993 WC-A / 3.0, CPC-B / 2.0 / 3.0 / 4.0 [FFl]-2-4-1 ........................ RING PATIFRNS FOR UNA TERMINALS (M.C & Bl ........... 1 set on 3 set OR ...... 37 [FFl]-2-4-(2-g) ................... EXTERNAL PAGE CONTROL FOR PAGING CROUPS .......... No settings ............... 37 ml]-2-5-(l-8)-( l-20) ............ EXIENSION CIASS OF SERVICE (CPC-B 3.0) ........................ Class 0 ...................... 37 l~11-2~~1-100)-@001-~l.. .......
Page 150
DBS Programming Instructions Section 40OFFi CPC-A/ 3.0, CPC-B / 2.0 / 3.0 /4.0 Issue 3 July 1993 [FFl]-8-4-2-8 . . . . . . . . . . . . . . . . .._. . . ANSWER SUPERV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .._........... 600 ms [FFlj-8-4-2-9 . . . . ..I............... IMM-GLARE -lIMER . ..-..........._..... 61 [FFlj-8-4-2- 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60...