Page 131

Installation, Section 300 
issue 2 Specifications 
August 30,1993 
Part No. Description Quantity 
+ 
+ 
+ 
+ 
+ 
+ 
S% 2% 
22 %:$3 
%2 
Z$ 
8s 22 QQ 22 2% 
Qf=l qa 2% 22 
f2Q Qf3 
Expansion Connectors 
VB-43 120 Trunk expansion 
2 2 
connector 
2 2 2 2 -.-.- 
VB-43 12 1 Extension expansion 
1* 0* 
connector 
Doorbox Equipment 
VB-4370 
1 Door box adaptor 24 24 48 48 58 64 
VB-43705 Door box 48 48 96 96 112 128 
Optional Equipment 
VB-43706 
Remote Administration 
Interface (RA 1-A) 
- 1 1 1 1 1 1...

Page 132

Installation, Section 300 
Issue 2 Specifications 
August 30,1993 
Cabling Specifications 
Table 7-11. Maximum cabling distances 
Loop Type and Resistance Resistance 
Cable Gauge Maximum Cabling Length in Feet 
(A WG) (Distance from the DBS) 
Key phone, EM/24 22 1239 
40 Ohms 24 779 
26 490 
DSS/72 22 619 
20 Ohms 24 779 
26 490 
SLT 22 3097 
00 Ohms 24 1948 
26 1225 
OPX (Loop between the 
DBS and the OPX Adap- 
tor) 22 
._ 309 
10 Ohms 24 194 
26 122 
OPX (Loop between the 
DPX Adaptor and a push-...

Page 133

Installation, Section 300 
Issue 2 Specifjcations 
August 30,1993 
Communiciition Parameters 
Table 7-12. Voice path from KTELs to DBS 
Channel 
Overall communications path 
D-channel data 
i B-channel data 
Speed 
256 kbps 
16 kbps 
64 kbps 
Table 7-13. Data communications ports 
‘art 
MDR 
Parameters 
Interface 
Baud rate 
Parity 
IStop bit length 
IData bit length RS232-C 
300,1200,4800 or 9600 kbps 
Even, odd, or none 
11, 1.5, or 2 
IS, 6,7, or 8 
4aintenance (RAI 
card) (Baud rate I300 (RAI-A) or...

Page 134

Installation, Section 300 
Issue 2 Specifications 
August 30,1993 
Signaling Characteristics 
Table 7-14. Signaling to CO 
Item 
Specif”rcation 
Dial pulse 
8 to 11 pulses per second (PPS) 
Break ratio 
58 to 64% 
Minimum pause 
0.7 to 1.0 seconds 
Trunk start 
Loop or ground start 
Table 7-15. Signaling levels 
Item 
Trunk input (DISA) 
Output from DBS 
(at MDF) 
Analog station input 
(Dial status) 
Analog station output 
(Talk path originated from a 
key phone to an SLT) 
Level Distortion 
-40 dBm...

Page 135

Installation, Section 300 
Issue 2 Specifications 
August 30,1993 
Tone Characteristics 
Table 7-17. Tone Phn 
Tone Name 1 Frequency 
Timing (seconds) 
CO Call Tones 
CO 
incoming call 550/400 Hz at 16 Hz Programmable 
Hold recall 55OMOO Hz at 16 Hz 
0.5 on/3.5 off 
Transfer recall 550/400 Hz at 16 Hz 
0.5 on/3.5 off 
Trunk queuing 550/400 Hz at 16 Hz 
0.5 on/O.5 off/O.5 on/2.5 off 
CO offhook signal 
550 Hz 
logoff 
Internal Tones (Key Phones) 
Dial 
tone 4OOHz Continuous 
CO incoming call 550 Hz 
1...

Page 136

Installation, Section 300 
Issue 2 
Specifications 
August 30,1993 
I Tone Natie I Frequency 
1 Voice mail ringing 1 SO/400 Hz at 16 Hz 
2 on/2 off 
Table 7-18. DTMF frequencies 
Digit 
Frequency (.Hz) 
1 
697 + 1209 
t I 2 
697 + 1336 
3 697 + 1477 
4 770 + 1209 
5 770 + 1336 
6 770 + 1477 
7 852 + 1209 
8 852 + 1336 
9 852 + 1477 
* 941 + 1209 
0 941 + 1336 
# 941 + 1477 
7-17  

Page 137

Installation, Section 300 
Issue 2 Index 
August 30,1993 
ltidex 
A DSLTs 
Analog extensions 4-34 installation 4-37 
wall mounting 3- 16 
B DSS/72 4-37 
DTMF frequencies 7- 17 
Background music 5-8 
Battery backup 
E 
capacities 7-3 
installation 3-9 
C 
Cabinet installation 3- 19 
batteries 3-9 
cards 3-6 
DSLT wall mounting 3- 16 
grounding 3-5 
key phone wall mounting 3- 13 
system iinitialization 3-19 
test phone 3-20 
wall mounting 3-3 
Cabling distances 7- 13 
Card installation 3-6 
Channel service...

Page 138

Installation, Section 300 
issue 2 
M 
MFR cards 
in double-cabinet systems 6-4 
slot locations 2-7 
strap S3 6-10 
Model numbers l-3 
Mounting brackets 3-4 
Music-on-hold 5-8 
N 
Network address signaling code l-3 
Network interface codes l-3 
New function reset 4- 18,4-25,4-27 
0 
OPX 5- 10 
P 
Paging 5-14 
Part numbers 
VA-43703 5- 18 
VB-2450A-2P 3-9 
VB-2650-2P 3-9 
VB-43030 l-3 
VB-43 120 4-4 1 
VB-43121 4-41 
VB-435 11 4-6 
VB-4370 1 5-25 
VB-437025-10 
VB-43705 5-25 
VB-43706 5-6 
VB-43707 5-6...

Page 139

Installation, Section 300 
Issue 2 
Trunks 
maximums 2-5,7-j 
trunk expansion 4-4 1 
trunk numbering 
single-cabinet systems 4- 11 
Trunks and lines 4- 1 
U 
UNA device 5-16 
V 
VA-43703 5- 18 
VAU 5-21 
VB-2450A-2P 3-9 
VB-2650-2P 3-9 
VB-43050 l-3 
VB-43060 l-3 
VB-43 110 4-9 
VB-43 120 4-4 1 
VB-431214-41 
VB-4354 1 4-6 
VB-4356 l-4-9 
VB-43562 4-9 
VB-43563 4-9,4- 19 
VB-43564 4-9,4-25 
VB-4370 1 5-25 
VB-43702 5- 10 
VB-43705 5-25 
VB-43706 5-6 
VB-43707 5-6 
VB-43708 5-2 1 
Voice Announce Unit 5-21...

Page 140

MCC/Panasonic’ 
Business Telephone, Engineering Department 
TO: All DBS Dealers 
FROM: MCC/Panasonic 
Business Telephone, Engineering Department 
DATE: July 30, 1993 
SUBJECT: Documentation Update 
This documentation update contains new versions of 
Programming Guidance (Section 400) and 
Forms and Tables (Section 450). 
These manuals replace the existing versions of Sections 400 and 450. 
In addition, 
Feature Operation (Section 700) has recently been updated and is now being shipped 
with new CPC...
Start reading Panasonic Digital Business System Section 300 Installation Guide

Related Manuals for Panasonic Digital Business System Section 300 Installation Guide

All Panasonic manuals