Page 101
Installation, Section 300 Issue 2 Figure 5-9. Cable punch-out plate, Power Failure Unit Peripheral Equipment August 30,1993 3. Mount the PFU on the wall using the three screws provided with the unit. (See Figure 5-10.) 4. Connect the trunks from the central office to the PFU. 5. Connect the SLTs to the AEC extension ports on the PFU. 6. Connect the trunks from the DBS to the PFU. 7. Connect the AEC ports from the DBS to the PFU. When a power failure occurs, AEC “A” is switched to Trunk “A,”...
Page 102
Installation, Section 300 Issue 2 Peripheral Equipment August 30,1993 P ‘igure S-IO.Power Failure Unit (PFU) installation From the Maln Cabtnel AEC Extension Porl No. A AEC Extension Port No. 8 i AEC Extension Porl No. C t&C Extension Porl NO. D To rhe Main TRK Porl No. 0 Cabinet TRK Pan No. C AEC Extension Pan No. AEC ExWnston Pofl No. C To SLT - Trunk Line A l- - Trunk Line e Tn thy central CXlice _ . in. To +24V and GND on CN2 d me t&in Cabinet (no polarization) f...
Page 103
Installation, Section 300 Peripheral Equipment Issue 2 August 30,1993 : Voice Announce Unit (VAU) Guidelines l Operating temperatures for the Voice Announce Unit (VB-43708) should be between 35 and 105” F. l Maximum loop resistance for the VAU is 10 Ohms. l The VAU contains a rechargeable lead-acid battery. Recharging circuity for the battery is included on the VAU. 0 The ports used for the VAU must have all FF key assignments cleared before voice messages and abbreviated dial numbers are...
Page 104
Installation, Section 300 Issue 2 Table 5-7. Switch settings for delay answer timing, VAU Table 5-8. Switch settings for DTMF detection timing, VAU Switch Block I (SWI) DTMF Detection Timer Switch Function 4 ON=80 rns OFF=40 ms Peripheral Equipment August 30; 1993 Table 5-9. Swi&h settings for wait timing between dialed digits, VAU Switch Block 2 (SW2) Wait Time Between Dialed Digits (Switches 5-6) I Switch 5 Time (in seconds) 2 6 IO 14 OFF OFF ON ON 1 OFF 1 ON 1 OFF 1 ON 1 5-22
Page 105
Installation, Section 300 Peripheral Equipment Issue 2 August 3.0, 1993 Table S-10. Switch seatings for abbreviated dialing digit length, VAU Switch Block 2 (S W2) Abbreviated Dialing Digit Length (Switches 7-8) 1 Switch Number of Digits 1 Digit 2 Digits 3 Digits 7 OFF OFF ON 8 OFF ON OFF 3. Remove the cable punch-out plate (Figure 5- 11) to make an opening for the cable coming into the VAU. To remove the plate, cut the grooves on either side with diagonal cutters. Then bend the plate...
Page 106
Installation, Section 300 Peripheral Equipment Issue 2 August 30,1993 CNl on ihe bottom of the VAU I \M/ Port2 ,’ f i 5-24
Page 107
Installation, Section 300 issue 2 Peripheral Equipment August 30, 1993 Door Box AdaDtor Guidelines l The Door Box Adaptor (VB-43701) requires a door opener and door sensor. In addition, a Door Box (VA-43705) is normally used with the Door Box Adaptor. The door opener and door sensor are not sold by Panasonic; they can be purchased separately from an electronics dealer. l Each Door Box and opener use one trunk port. Also, each sensor uses one trunk port 0 Up to two door openers and two Door...
Page 108
Installation, Section 300 Issue 2 Peripheral Equipment August 30,1993 Figure S-14.Cable punch-out plate, D L 4. 5. 6. Mount the Door Box Adaptor on the wall using the three screws provided with the unit. Connect the trunk line(s) to the Door Box Adaptor, as shown in Figure 5-15. /- The “CO-D” connector is used for the Door Box and opener. The “C0.S” connector is used for the sensor. Connect the Door Box, door opener, and sensor to the Door Box Adaptor. 5-26
Page 109
Installation, Section 300 Peripheral Equipment Issue 2 August 30,1993 Figure 5-lS.InstaUation of the door box, door opener, and door sensor 12345676 DoorBoxAdefstor(vw3701) Contact Ratings for Opener 1 and 2: 120V AC: 0.3 amps 30V DC: 1 amp Dl3S40 DBS721llBS96 5-27
Page 110
installation, Section 300 Issue 2 Double-Cabinet Systems August 16, 1993 Chapter 6. Double-Cabinet Svstems Two DBS cabinets can be connected in order to increase linesize. This chapter includes connection procedures, as well as capacities for two-cabinet systems. See Chapter 4 for instructions on installing Tls in two-cabinet systems. 6-l