Page 111
installation, Section 300 Double-Cabinet Systems Issue 2 August l&1993 Guidelines Two DBS cabinets can be connected to increase linesize. The maximum linesize consists of two DBS 96 cabinets, which provide 192 ports. CPC-B and SCC-B are required for two-cabinet systems. If ground start or DID trunks are used in both cabinets, separate -48V supplies must be supplied for each cabinet. If SLTs are used in both cabinets, separate SLT ringer boxes must be supplied for each cabinet. The following...
Page 112
Installation, Section 300 Double-Cabinet Systems Issue 2 August 16, 1993 i Figure 6-I. Slot usage for two-cabinet systems, DBS 40 + DBS 40 DBS 40 (Slave) TRKl EC1 EC2 EC3 EC/TRK SCC CPC AUXl AUX2 5 DBS 40 (Master) *See “Tl Interface” on page 4-9 for EC/TRK port numbers for Tl. #A maximum of two MFR cards can be installed in a two-cabinet system. With Cable Kit Version 1.1, one MFR is installed in the Master AUXl, and one MFR is installed in the Slave AUX 1. With Cable Kit Version 1.2, both...
Page 113
Installation, Section 300 Issue 2 Double-Cabinet Systems August 16,1993 Figure 6-2. Slot usage for two-cabinet systems, DBS 72 + DBS 40 DBS 40 (Slave) TRKl EC1 EC2 EC3 EC/TRK SCC CPC AUXI AUX2 xl G + G Y 8 z t- s; z ik ir 9 f t: ii ; $ ? ii z 2% 0 Notes: DBS 72 (Master) TRK EC5 EC6 I I EC/ TRK *A maximum of two MFR cards can be installed in a two-cabinet system.Wlth Cable Kit Version 1.1, one MFR is installed in the Master AUXl, and one MFR is installed in the Slave AUX 1. With...
Page 114
Installation, Section 300 Issue 2 Double-Cabinet Systems August 1.6, 1993 Figure 6-3. Slot usage for two-cabinet systems, DBS 72 + DBS 72 DBS 72 (Slave) DBS 72 (Master) TRK1 TRK2 EC1 EC2 EC3 EC4 EC5 EC6 EC/TRK SCC CPC AUXl AUX2 Notes: YSee “Tl Interface” on page 4-9 for EC/TRK port numbers for Tl. Beginning with CPC-B Version 4, the EC/TRK slot in the slave DBS 72 can be used for trunks or lines. Prior to CPC-B Version 4, this slot could only be used for lines. ,‘A maximum of two MFR cards...
Page 115
installation, Section 300 Double-Cabinet Systems Issue 2 August 16,1993 Figure 64. Slot usage for two-cabinet systems, DBS 96 + DBS 40 DBS 40 (Slavej DBS 96 (Master) *See “Tl Interface*’ on page 4-9 for EC/IRK port numbers for Tl. “A maximum of two MFR cards can be installed in a two-cabinet system. With Cable Kit Version 1.1, one MFR is installed in the Master AUX 1, and one MFR is installed in the Slave AUX 1. With Cable Kit Version 1.2, both MFR cards are installed in the slave cabinet--one in...
Page 116
Installation, Section 300 Issue 2 Double-Cabinet Systems August 16,1993 Figure 6-5. Slot usage for two-cabinet systems, DBS 96 + DBS 72 DBS 72 (Slave) TRKl TRKZ EC1 EC2 EC3 EC4 EC5 EC6 EC/TRK SCC CPC AUXl AUX2 DBS 96 (Master) TRKl TRK2 TRK3 EC1 EC2 EC3 EC4 EC5 EC6 EC7 EC8 EC/TRK SCC CPC AUXl AUX2 b *See “Tl Interface” on page 4-9 for EC/IRK port numbers for Tl. #A maximum of two MFR cards can be installed in a two-cabinet system. With Cable Kit Version 1.1, one MFR is installed in the Master...
Page 117
I EXT l-8 EXT 17-24 F EXT 25-32 TRK 25-32* or CBL-M TRK 33-40 I I 5;1 x EXT 81-88 g I I N EXT89-96 8 cd EXT 97-l 04 B EXT 105-112 ; EXT 113-120 % Q, EXT 121-128 $ EXT 129-136 ; TRK 57-64* or 5 ,,,,
Page 118
Installation, Section 300 Issue 2 Double-Cabinet Systems August 16,1993 Installation 1. Install the trunk and extension cards according to the layouts shown in the Figures 6- 1 through 6-6. Note that the port numbers for each slot are fixed. 2. If you’re using two MFR cards, cut Strap S3 on the second card. Figure 6-7. Strap 3, MFR card i 3. Using the cables provided, connect the CBL-M card in the master cabinet to the CBL-S card installed in the slave cabinet. ( Note: The EM1 filter must be...
Page 119
Installation, Section 300 Issue 2 Double-Cabinet Systems August 16,1993 Figure 6-8. Double-cabinet installation Digital Deskset Pmgramming ~01-10 Stave Cabinet SMDR Printer Master Cabinet 4. Connect two 24V power supply cords from the CE3L-S card to the 24V and GND terminals on CN2 of the Connector Panel of the slave cabinet. Figure 6-9. CBL-S to Connector Panel connection, slave cabinet CBL-S CARD 6-l 1
Page 120
Installation, Section 300 Issue 2 Double-Cabinet Systems August 16,1993 5. Set SW 1 on the CBL-M card according to the following table. Table 6-2. CBL-M switch settings System Combinations Switch Settings Master Slave 1 2 3 4 5 6 7 8 DBS40 DBS40 ON ON ON ON ON ON OFF ON DBS72 DBS40 ON OFF ON ON ON ON OFF OF@ DBS72 DBS72 ON OFF ON OFF ON OFF ON OFF DBS96 DBS40 OFF ON OFF ON ON OFF OFF OFF DBS96 DBS72 OFF ON OFF ON ON OFF OFF OFF DBS96 DBS96 OFF ON OFF ON ON OFF OFF OFF f- 6-l 2