Applica ble piping kit CZ-3F5, 7AEN (XC9CK) CZ-4F5, 7, 10AN (XC12CK) SELEC T THE BEST LOCATION INDOOR UNIT • • • • There should not be any heat source or steam near the unit. • • • • There should not be any obstacles blocking the air circulation. • • • • A place where air circulation in the room is good. • • • • A place where drainage can be easily done. • • • • A place where noise prevention is taken into consideration . • • • • Do not install the...
Page 42
10.2.1. SELECT THE BESTLOCATION (Refer to “Select the best location” section) 10.2.2. HOW TO FIX INSTALLATION PLATE The mounting wall is strong and solid enough to prevent itfrom the vibration. The centre of installa tion plate should be at more than 450 mm at right and left of the wall. The distance from installa tion plate edge toceiling should more than 67 mm. From installa tion plate left edge to unit’s left side is 47 mm. From installa tion plate right edge to unit’s right is 73 mm. : : :For left...
Page 43
3. For the embedded piping (This can be used for left rear piping & left bottom piping also.) 43 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ
Page 44
10.2.5. CONNECT THECABLE TO THE INDOOR UNIT 1. The inside and outside connecting cable can be connected without removing the front grille. 2. Conne cting cable between indoor unit and outdoo r unit shall be approved polychloropre ne sheathed 5 (XC9CK, XC12CK)×1.5 mm 2flexible cord, type designation 245 IEC 57 or heavier cord. • • • • Ensure the color of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively. • • • • Earth lead wire shall be longer than...
Page 45
HOW TO TAKE OUT FRONT GRILLE Please follow the steps below to take out front grille if necessary such as when servicing. 1. Set the vertical airflow direction louver to the horizon tal position. 2. Slide down the two caps on the front grille as shown in the illustration below, and then remove the two mounting screws. 3. Pull the lower section of the front grille towards you to remove the front grille. Whenreinstalling the front grille, first set the vertical airflow direction louver to the horizontal...
Page 46
CUTTING ANDFLARING THE PIPING 1. Please cut using pipe cutter and then remove the burrs. 2. Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused. Turn the piping end down to avoid the metal powder entering the pipe. 3. Please make flare after inserting the flare nut onto the copper pipes. (1)* *Connect the manifold gauge to the service port of 3-way valve. Measure the pressure.(2)* *Keep it for 5-10 minutes. Ensure that the pressure indicated on the gauge is the same as...
Page 47
CHECK THE DRAINAGE • • • • Open front panel and remove air filters. (Drainage checking can be carried out without removing the front grille.) • • • • Pour a glass of water into the drain traystyrofoam. • • • • Ensure that water flows out from drain hose of the indoor unit. EVALU ATION OF THE PERFORMANCE • • • • Operate the unit at cooling operation mode for fifteen minutes or more. • • • • Measure the temperature of the intake and discharge air. • • •...
Page 48
10.3.7. OXYGEN TUBE CONNECTION Precautions during oxygen tube connection 1. Tube allowable length and height difference is the same as pipes. 2. Tube should be pulled without folding it along the path of refrigerant pipe, providing sufficie nt allowance and cut to length. • • • • If there is no allowance, tube length will contract when temperature changes and it may cause trouble. • • • • On the other hand, tube length used without cutting and in the form of loop too should be...
Page 49
11 2-way, 3-way Valve 2-way Valve (Liquid Side)3-way Valve (Gas Side) WorksShaft PositionShaft PositionService Port ShippingCloseCloseClose (With valve cap)(With valve cap)(With cap) EvacuationCloseCloseOpen (Installation and(Counter-Clockwise)(Clockwise)(Push-pin) Re-installation) OperationOpenOpenClose (With valve cap)(With valve cap)(With cap) Pumping downCloseOpenOpen (Transferring)(Clockwise)(Counter-Clockwise)(Connected manifold gauge) EvacuationOpenOpenOpen (Servicing)With vacuum pump Gas...
Page 50
Required tools: hexago nal wrench, adjustable wrench, torque wrenches, wrench to hold the joints and gas leak detector. The additio nal gas for air purging has been charged in the outdoor unit. However, if the flare connections have not been done correctly and there gas leaks, a gas cylinde r and the charge set will be needed. 1. Recheck the piping connections. 2. Open the valvestem of the 2-wayvalvecounter- clockwise approximately 90°,wait 10seconds, and then set it to closed position. • • • •...