Page 14
REMARKS B: BLUEP: PINK BR: BROWNR: RED BL: BLACKW: WHITE G: GREENY: YELLOW GRY: GRAYY/G: YELLOW/G REEN O: ORANGE Resistance of Indoor Fan Motor Windings MODELCS-XC9CK CS-XC12CK CONNECTIONCWA921181 BLUE-YELLOW390Ω YELLOW-RED390Ω Note: Resistance at 20°C/25°C of ambient temperature. Resistance of Outdoor Fan Motor Windings MODELCU-XC9CK CU-XC12CK CONNECTIONCWA951128 BLUE-YELLOW210.7Ω YELLOW- RED196.5Ω Note: Resistance at 20°C of ambient temperature. Resistance of Compressor Windings MODELCU-XC9CKCU-XC12CK...
Page 15
8 Operation Details 8.1. Indoor Fan Speed Control • • • • Auto Fan Speed Control When set toAuto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table. • • • • Manual Fan Speed Control Basic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection button at the remote control. 15 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ
Page 16
Coolin g in operation according to Remote Control setting. Time DelaySafety Control (3 minutes) 7 minutes TimeSave Control Starting Current Control Anti-Freezing Control • • • • If the temperature of the indoor heat exchan ger falls continuously below 2°C for 4 minutes or more, the compressor turns off to protect the indoor heat exchan ger from freezing. The fan speed setting remains the same. • • • • Compressor will restart again when the indoor heat exchan ger temperature rises to...
Page 17
Automatic Fan Speed Mode Cooling Operation Time Diagram When Automatic Fan Speed is selected at Remote Control during cooling operation. • • • • Fan speed rotates in the range of Hi to Me. • • • • Deodorizing Control. 17 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ
Page 18
Quiet Operation Control (For Coolin g Mode or cooling region of Soft Dry Mode) • • • • Purpose of this operation is to provide quite cooling operation compare to normal operation. • • • • W hen the Quiet Mode is set at the remote control, Quiet Mode LED illuminates, the sound level will be automatically decreased 2 dB (Lo), decreased 3 dB (Hi, Me), against the present sound level operation. • • • • Quiet setting of fan speed rpm refer to Indoor Fan Speed Control. • • •...
Page 19
Time DelaySafety Control Starting Current Control Anti-Freezing Control Compressor Reverse Rotation Protection Control Automatic Fan Speed Mode 8.3. Soft Dry Mode Operation • • • • The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and then Soft Dry operation will start. • • • • During Soft Dry operation, the Indoor Fan will operate at Lo- speed. • • • • The operation will be switched on and off for up to 10...
Page 20
Soft Dry Operation Time Diagram Quiet Operation Control (For Dry region of Soft Dry Mode) 20 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ